13.07.2015 Views

CERTIFICATE NUMBER DATE 12-LD904603A-PDA 07 June ... - TKF

CERTIFICATE NUMBER DATE 12-LD904603A-PDA 07 June ... - TKF

CERTIFICATE NUMBER DATE 12-LD904603A-PDA 07 June ... - TKF

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Certificate Number: <strong>12</strong>-<strong>LD904603A</strong>-<strong>PDA</strong>21/OCT/2013Confirmation of Product Type ApprovalPlease refer to the "Service Restrictions" shown below to determine if Unit Certification is required for this product.This certificate reflects the information on the product in the ABS Records as of the date and time the certificate isprinted.Pursuant to the Rules of the American Bureau of Shipping (ABS), the manufacturer of the below listed product helda valid Manufacturing Assessment (MA) with expiration date of <strong>07</strong>/OCT/2018. The continued validity of theManufacturing Assessment is dependent on completion of satisfactory audits as required by the ABS Rules.And; a Product Design Assessment (<strong>PDA</strong>) valid until 06/JUN/2017 subject to continued compliance with the Rulesor standards used in the evaluation of the product.The above entitle the product to be called Product Type Approved.The Product Design Assessment is valid for products intended for use on ABS classed vessels, MODUs or facilitieswhich are in existence or under contract for construction on the date of the ABS Rules used to evaluate theProduct.ABS makes no representations regarding Type Approval of the Product for use on vessels, MODUs or facilitiesbuilt after the date of the ABS Rules used for this evaluation.Due to wide variety of specifications used in the products ABS has evaluated for Type Approval, it is part of ourcontract that; whether the standard is an ABS Rule or a non-ABS Rule, the Client has full responsibility forcontinued compliance with the standard.Product Name: Cable, Flame Retardant High Voltage Power CablesModel Name(s): MarinePowerFlex YOZmv (single conductor) & YZOZmv (tripleconductor) 6/10kVPresented to:BV Twentsche KabelfabriekSpinnerstraat 15Postbus 6HaaksbergenNetherlandsIntended Service:Description:Ratings:Service Restrictions:High Voltage fixed power installation on board ship and offshore installationsArmoured high voltage power cable, Cu class 5 conductors, XLPE insulation, flameretardant halogen free polyolefin outer sheath.YOZmv 1x240 YZOZmv 3x50, 3x70, 3x95, 3x<strong>12</strong>0, 3x150 Nominal voltages U06kV, U 10kV, Umax <strong>12</strong>kV Max conductor temperature 90C, operating temperature-20C to +70C (flexible), -40C to +70C (fixed)Unit Certification is not required for this product. Records of test are to bemaintained and are to be available to ABS upon request in accordance with4-8-3/9.17 of the Steel Vessel Rules 20<strong>12</strong>.Comments: Cable types MarinePowerFlex YOZmv 1x16, 1x25, 1x35, 1x50, 1x70, 1x95, 1x<strong>12</strong>0,1x150, 1x185, 1x300, 1x400, 1x500, 1x630 and YZOZmv 3x16, 3x25, 3x35, 3x185,3x240, 3x300, 3x400, 3x500, 3x630 are acceptable if accompanied by aManufacturers Routine Test ReportNotes / Documentation:Test reports: BV Twentsche Kabelfabriek Report No. 408, 6 Jan 2009; KEMA T&DReport 09-<strong>12</strong>26, 5 Mar 2009, BRE Global Reports 250467-1 and 250467-2 23 Feb2009, QED Test Report 016-1033-2008-R1 21 Jan 200910/21/2013 4:<strong>12</strong>:43 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 1 of 2


Certificate Number: <strong>12</strong>-<strong>LD904603A</strong>-<strong>PDA</strong>Term of Validity:ABS Rules:National Standards:International Standards:Government Authority:EUMED:Others:This Product Design Assessment (<strong>PDA</strong>) Certificate <strong>12</strong>-<strong>LD904603A</strong>-<strong>PDA</strong>, dated<strong>07</strong>/Jun/20<strong>12</strong> remains valid until 06/Jun/2017 or until the Rules or specificationsused in the assessment are revised (whichever occurs first). This <strong>PDA</strong> is intendedfor a product to be installed on an ABS classed vessel, MODU or facility which is inexistence or under contract for construction on the date of the ABS Rules orspecifications used to evaluate the Product. Use of the Product on an ABS classedvessel, MODU or facility which is contracted after the validity date of the ABS Rulesand specifications used to evaluate the Product, will require re-evaluation of the<strong>PDA</strong>. Use of the Product for non ABS classed vessels, MODUs or facilities is to beto an agreement between the manufacturer and intended client.The Manufacturer has provided a declaration about the control of, or the lack ofAsbestos in this product. The Rules applicable to this assessment are: 20<strong>12</strong> SteelVessel Rules 1-1-4/7.7; 4-8-3/9.1, 9.3, 9.5, 9.9, 9.11, 9.17; 4-8-5/3.7.6IEC 60092-350 Ed3.0:2008, 60092-351 Ed3.0:2004, 60092-354 Ed2.0:2003,60092-359 Ed1.2:1999, 60332-1-1/2 Ed1.0:2004, 60332-3-22 Ed1:2000 am1:2008;6<strong>07</strong>54-1 Ed2.0:1994; 61034-2 Ed3.0:2005Model Certificate Model Certificate No Issue Date Expiry Date<strong>PDA</strong> <strong>12</strong>-<strong>LD904603A</strong>-<strong>PDA</strong> <strong>07</strong>/JUN/20<strong>12</strong> 06/JUN/2017ABS ProgramsABS has used due diligence in the preparation of this certificate and it represents the information on the product in the ABS Records as of thedate and time the certificate was printed. Type Approval requires Drawing Assessment, Prototype Testing and assessment of themanufacturer's quality assurance and quality control arrangements. Limited circumstances may allow only Prototype Testing to satisfy TypeApproval. The approvals of Drawings and Products remain valid as long as the ABS Rule, to which they were assessed, remains valid. ABScautions manufacturers to review and maintain compliance with all other specifications to which the product may have been assessed. Further,unless it is specifically indicated in the description of the product; Type Approval does not necessarily waive witnessed inspection or surveyprocedures (where otherwise required) for products to be used in a vessel, MODU or facility intended to be ABS classed or that is presently inclass with ABS. Questions regarding the validity of ABS Rules or the need for supplemental testing or inspection of such products should, in allcases, be addressed to ABS.10/21/2013 4:<strong>12</strong>:43 AM Copyright 2001 American Bureau of Shipping. All rights reserved. Page 2 of 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!