Also available from our standard pump range:End Suction <strong>Pumps</strong>SERIES 4280 SERIES 4030 SERIES 4039CLOSE COUPLED LONG COUPLED BELT DRIVENVertical In Line <strong>Pumps</strong>SERIES 4360 & 4380 SERIES 4300 SERIES 4382 & 4302 DUALARMCLOSE COUPLED SPLIT COUPLED TWIN C/W VALVINGGlanded Circulators Multistage SubmersibleS & H SERIES SERIES AM SERIES DOCOur policy is one of continuous improvement and we reserve the right to alter our dimensions and specifications without notice.<strong>Armstrong</strong> <strong>Pumps</strong> LimitedPeartree Road, StanwayColchester, EssexUK CO3 5JXTel 01206-579491Fax 01206-760532S.A. <strong>Armstrong</strong> Limited23 Bertrand AvenueToronto, OntarioCanada M1L 2P3Tel (416) 755-2291Fax (416) 755-8469<strong>Armstrong</strong> <strong>Pumps</strong> Inc.93 East AvenueBuffalo, New YorkU.S.A. 14120-6594Tel (716) 693-8813Fax (716) 693-8970<strong>Armstrong</strong> Darling Inc.2200 Place TranscanadienneMontreal, QuebecCanada H9P 2X5Tel (514) 421-2424Fax (514) 421-2436www.armstrongpumps.comAP825/A


ARMSTRONGSERIES <strong>AG</strong>LEAFLET: K2.110DATE: MARCH 2001SUPERSEDES: K3.31DATE: NOV 1995Glandless Circulators


<strong>AG</strong>S SINGLE HEAD • <strong>AG</strong>S SINGLE HEAD • <strong>AG</strong>S SINGLE HEADGeneral ApplicationsDesigned to provide maintenance free operationin LTHW, MTHW and Chilled Water systems forlight commercial installations, including: offices,schools and hospitals.FeaturesMultispeed selectionNo servicing requiredTemperature range -20 to +130 Deg. CAutomatic venting of rotor chamberFlows up to 18.5 l/sMounting Position(B) : Position notrecommendedfor chilledwater.Material SpecificationPART NAME<strong>AG</strong>S SINGLE HEADVOLUTECAST IRON BS1452IMPELLERCOMPOSITECANSTAINLESS STEELMOTOR SHAFTSTAINLESS STEELMIN/MAX TEMP. -20 to +130 DEG. C*MSWP10 BARBEARINGSGRAPHITECASING SEALETHYLENE PROPYLENETYPICALAIR CONDITIONING, HEATING,APPLICATIONSPRIMARY HOT WATER SERVICE* Models <strong>AG</strong>S 25-12-1 and <strong>AG</strong>S 32-50-1 +1 to +110 Deg. CSilent operationAvailable in single and three phaseMaximum working pressure 10 barFull torque startingHeads up to 180 kpa(B)Motor SpecificationSTD WET ROTORIP RATINGIP42INSULATIONCLASS FBEARINGSSLEEVE LUBRICATED BYPUMPED MEDIUMMAX. AMBIENT TEMP.40 DEG. CELEC. SUPPLY 200-240V/1PH/50HZ-380-420V/3PH/50HZTemperature Range &Minimum Suction Head (M.W.G.)MODEL TEMP RANGE 70˚C 82˚C 95˚C 110˚C 130˚C<strong>AG</strong>S 25-12 -10˚ to 110˚C 0 1.5 3 10 –<strong>AG</strong>S 32-50 -10˚ to 110˚C 0 1.5 3 10 –<strong>AG</strong>S 32-75 -20˚ to 110˚C 0 2 3 10 –<strong>AG</strong>S 32-80 -20˚ to 130˚C 8 10 13 19 32<strong>AG</strong>S 40-40 -20˚ to 130˚C 5 7 10 16 29<strong>AG</strong>S 50-50 -20˚ to 130˚C 7 9 12 18 31<strong>AG</strong>S 50-90 -20˚ to 130˚C 8 10 13 19 32<strong>AG</strong>S 80-25 -20˚ to 130˚C 8 10 13 19 32<strong>AG</strong>S 65-90 -20˚ to 130˚C 12 13 15 23 38<strong>AG</strong>S 80-50 -20˚ to 130˚C 7 9 12 18 31<strong>AG</strong>S 80-801 -20˚ to 130˚C 12 13 15 23 38<strong>AG</strong>S 80-802 -20˚ to 130˚C 12 13 15 23 381


<strong>AG</strong>B BRONZE • <strong>AG</strong>B BRONZE • <strong>AG</strong>B BRONZEkPaPump Performance Range70605040<strong>AG</strong>B25-6430<strong>AG</strong>B25-5920<strong>AG</strong>B20-5010<strong>AG</strong>B15-2500.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 L/SFor exact speed setting please refer to individual performance curves.Typical Dimensions and WeightsMODEL PORTS/ W L H C H1 WEIGHTFLANGESKG<strong>AG</strong>B 15-25-1 20MM BSP 96 130 130 74 96 2<strong>AG</strong>B 20-50-1 25MM BSP 123 158 132 77 96 2.4<strong>AG</strong>B 25-59-1 25MM BSP 96 180 145 77 109 2.8<strong>AG</strong>B 25-64-1 25MM BSP 97 180 174 84 146 3.2For certified dimensions refer to Colchester office. *Mating flanges supplied.H1CLUNIONCONNECTIONSWH6


<strong>AG</strong>B BRONZE • <strong>AG</strong>B BRONZE • <strong>AG</strong>B BRONZEGeneral ApplicationsDesigned for secondary circulation in hot watersystems and other applications where the use ofcorrosion resistant materials is essential for longterm reliability.FeaturesMountingPositionMultispeed selectionNo servicing requiredTemperature range +10 to +110 Deg. CAutomatic venting of rotor chamberFlows up to 1.5 l/s(B) : Position notrecommendedfor chilledwater.Material SpecificationSilent operationMaximum working pressure 10 barFull torque startingHeads up to 65 kpa(B)Motor SpecificationPARTNAMEVOLUTEIMPELLERCANMOTOR SHAFTMIN/MAX TEMP.MSWPBEARINGSCASING SEALTYPICALAPPLICATIONS<strong>AG</strong>BSINGLE HEAD BRONZEBRONZE BS1400COMPOSITESTAINLESS STEELSTAINLESS STEEL+10 to +110 DEG. C10 BARGRAPHITEETHYLENE PROPYLENESECONDARY HOTWATER SERVICEIP RATINGINSULATIONBEARINGSMAX. AMBIENT TEMP.ELEC. SUPPLYSTD WET ROTORIP42CLASS FSLEEVE LUBRICATED BYPUMPED MEDIUM40 DEG. C220-240V/1PH/50HZMinimum Suction Head (M.W.G.)MODEL 70˚C 90˚C 110˚C 130˚C<strong>AG</strong>B 15-25 1.1 3 10 –<strong>AG</strong>B 20-50 1.1 3 10 –<strong>AG</strong>B 25-59 1.1 3 10 –<strong>AG</strong>B 25-64 1.1 3 10 –5


<strong>AG</strong>S SINGLE HEAD • <strong>AG</strong>S SINGLE HEAD • <strong>AG</strong>S SINGLE HEADPump Performance Range10<strong>AG</strong>S 32-75<strong>AG</strong>S 32-80kPa<strong>AG</strong>S 32-50<strong>AG</strong>S80-801<strong>AG</strong>S80-802<strong>AG</strong>S 25-121 2L/Sec0<strong>AG</strong>S50-90<strong>AG</strong>S65-90SEEINSET<strong>AG</strong>S40-40<strong>AG</strong>S50-50<strong>AG</strong>S80-25<strong>AG</strong>S80-50LCWThreaded ModelscFor exact speed setting please refer to individual performance curves.Typical Dimensions and WeightsMODEL PORTS/FLANGESW L H C W1 H1 WEIGHTKG<strong>AG</strong>S 25-12-1 25MM BSP 93 180 132 90 – 99 2.35<strong>AG</strong>S 32-50-1 32MM BSP 93 180 132 90 – 98 2.6<strong>AG</strong>S 32-75-1 32MM BSP 100 180 177 90 – 138 4.2<strong>AG</strong>S 32-80-1 32MM PN16* 142 180 228 90 73 185 7<strong>AG</strong>S 40-40-1 40MM PN16* 155 250 268 125 80 193 12<strong>AG</strong>S 50-50-1 50MM PN16* 174 280 308 140 91 225 18<strong>AG</strong>S 50-90-1 50MM PN16* 190 280 306 140 101 223 19<strong>AG</strong>S 80-25-1 80MM PN16* 244 360 358 180 135 258 29<strong>AG</strong>S 50-90-3 50MM PN16* 189 280 306 140 101 223 19<strong>AG</strong>S 65-90-3 65MM PN16* 218 340 349 170 118 256 28<strong>AG</strong>S 80-25-3 80MM PN16* 244 360 358 180 135 258 29<strong>AG</strong>S 80-50-3 80MM PN16* 244 360 358 180 135 258 31<strong>AG</strong>S 80-801-3 80MM PN16* 275 360 403 170 147 294 46<strong>AG</strong>S 80-802-3 80MM PN16* 275 360 403 170 147 294 48For individual certified dimensions refer to Colchester office. *Mating flanges suppliedW1H1CLWHFlanged Models2


<strong>AG</strong>T TWIN HEAD • <strong>AG</strong>T TWIN HEAD • <strong>AG</strong>T TWIN HEADGeneral ApplicationsDesigned to provide maintenance free operationsin LTHW, MTHW and Chilled Water systems.The integral second motor head may be used foreither standby purposes or parallel pumping.Typical installations include: offices, schools andhospitals.FeaturesMultispeed selectionNo servicing requiredTemperature range -20 to +130 Deg. CAutomatic venting of rotor chamberFlows up to 18 l/s (36 l/s parallel operation)Silent operationAvailable in single and three phaseMaximum working pressure 10 barFull torque startingHeads up to 180 kpaMounting Position(A) : possible mounting, butrequires a periodic changeoverto avoid the formation of anair trap at the high point, orconnection of a bleed to theport provided for it. ( 1/8 )(B) : position not recommended forchilled water. (A) (A) (B)Material SpecificationMotor SpecificationPART NAMEVOLUTEIMPELLERCANMOTOR SHAFTMIN/MAX TEMP.MSWPBEARINGSCASING SEALTYPICALAPPLICATIONS<strong>AG</strong>S SINGLE HEADCAST IRON BS1452COMPOSITESTAINLESS STEELSTAINLESS STEEL-20 to +130 DEG. C10 BARGRAPHITEETHYLENE PROPYLENEAIR CONDITIONING, HEATING,PRIMARY HOT WATER SERVICESTD WET ROTORIP RATINGIP42INSULATIONCLASS FBEARINGSSLEEVE LUBRICATED BYPUMPED MEDIUMMAX. AMBIENT TEMP.40 DEG. CELEC. SUPPLY 220-240V/1PH/50HZ-380-420V/3PH/50ZTemperature Range &Minimum Suction Head (M.W.G.)MODEL TEMP RANGE 70˚C 82˚C 95˚C 110˚C 130˚C<strong>AG</strong>T 40-40 -20˚ to 130˚C 5 7 10 16 29<strong>AG</strong>T 50-50 -20˚ to 130˚C 7 9 12 18 31<strong>AG</strong>T 50-90 -20˚ to 130˚C 8 10 13 19 32<strong>AG</strong>T 80-25 -20˚ to 130˚C 8 10 13 19 32<strong>AG</strong>T 65-90 -20˚ to 130˚C 12 13 15 23 38<strong>AG</strong>T 80-50 -20˚ to 130˚C 7 9 12 18 31<strong>AG</strong>T 80-801 -20˚ to 130˚C 12 13 15 23 38<strong>AG</strong>T 80-802 -20˚ to 130˚C 12 13 15 23 383


<strong>AG</strong>T TWIN HEAD • <strong>AG</strong>T TWIN HEAD • <strong>AG</strong>T TWIN HEADkPaPump Performance Range150<strong>AG</strong>T80-802100<strong>AG</strong>T80-801<strong>AG</strong>T65-9050<strong>AG</strong>T50-90<strong>AG</strong>T80-50<strong>AG</strong>T40-40<strong>AG</strong>T50-50<strong>AG</strong>T80-2500 5 10 15 20 L/SFor exact speed setting please refer to individual performance curves.Typical Dimensions and WeightsMODEL PORTS/FLANGESW L H C W1 H1 WEIGHTKG<strong>AG</strong>T 40-40-1 40MM PN16* 297 250 268 135 154 193 20<strong>AG</strong>T 50-50-1 50MM PN16* 348 280 308 160 179 225 31<strong>AG</strong>T 50-90-1 50MM PN16* 390 280 306 155 198 223 33<strong>AG</strong>T 80-25-1 80MM PN16* 480 360 358 205 249 258 51<strong>AG</strong>T 50-90-3 50MM PN16* 390 280 306 155 198 223 33<strong>AG</strong>T 65-90-3 65MM PN16* 432 340 349 185 223 256 49<strong>AG</strong>T 80-25-3 80MM PN16* 480 360 358 205 249 258 51<strong>AG</strong>T 80-50-3 80MM PN16* 480 360 358 205 249 258 55<strong>AG</strong>T 80-801-3 80MM PN16* 600 360 394 190 300 294 86<strong>AG</strong>T 80-802-3 80MM PN16* 600 360 394 190 300 294 90For individual certified dimensions refer to Colchester office. *Mating flanges suppliedW1H1CLWH4