13.07.2015 Views

TANKLESS RACK SYSTEM (TRS) SUBMITTAL SHEET - Rinnai

TANKLESS RACK SYSTEM (TRS) SUBMITTAL SHEET - Rinnai

TANKLESS RACK SYSTEM (TRS) SUBMITTAL SHEET - Rinnai

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TANKLESS</strong> <strong>RACK</strong> <strong>SYSTEM</strong> (TRS)Description(2, 3, 4) RU98Wall Mount(4/4, 3/4, 2/4)RU98Free Stand (b)(6/6, 5/6, 3/6)RU98Free Stand (b)Top Level Part No.RW2, RW3,RW4RS4-4, RS4-3,RS4-2RS6-6, RS6-5,RS6-3Rack Frame - Specifications RW2, RW3, RW4 RF4 RF6Frame Rail Type Sheet Metal Sheet Metal Sheet MetalFrame Material 0.090 5052-H32 0.090 5052-H32 0.090 5052-H32Frame Finish Powder Coat Powder Coat Powder CoatColor Gray Gray GrayWater & Gas ConnectionsHot Water Trunk Line Diameter 2" 2" 2-1/2"Cold Water Trunk Line Diameter 2" 2" 2-1/2"Hot Water Trunk Line Material Rigid Copper Rigid Copper Rigid CopperCold Water Trunk Line Material Rigid Copper Rigid Copper Rigid CopperWater Trunk Connection Type 2" MNPT 2" MNPT 2-1/2" MNPTWater Header End Cap (field supplied) 2” FNPT 2” FNPT 2-1/2” FNPTHot Water Branch Line Diameter 3/4" 3/4" 3/4"Cold Water Branch Line Diameter 3/4" 3/4" 3/4"Hot Water Branch Line Material CSST CSST CSSTCold Water Branch Line Material CSST CSST CSSTGas Trunk Line Diameter 1-1/4" NPT 1-1/4" NPT 1-1/2" NPTGas Trunk Connection Type 1-1/4” MNPT 1-1/4” MNPT 1-1/2” MNPTGas Header End Cap (field supplied) 1-1/4” FNPT 1-1/4” FNPT 1-1/2” FNPTGas Trunk Line Material Sch 40 Steel Sch 40 Steel Sch 40 SteelGas Branch Line Diameter 3/4" 3/4" 3/4"Gas Branch Line MaterialPVC Over CSST PVC Over CSST PVC Over CSSTGas Trunk Line Finish Powder Coat Powder Coat Powder CoatUniStrut Size 1-5/8" x 13/16" 1-5/8" x 1-5/8" 1-5/8" x 1-3/8"UniStrut Material 14ga Steel / Zn 12ga S/S 12ga S/SHardware Material/Finish Steel / Zn S/S 18-8 S/S 18-8Electrical Requirements(Installer shall provide electrical outletconnections)Each water heater requires 120 VAC, 60 Hz powersource in a properly grounded circuit.RU98i: 64 W normal operation; 2 W standby; 146 Wanti-frost protection.RU98e: 63 W normal operation; 2 W standby; 168 Wanti-frost protection.BTU and Flow Rates for Common Vented RU98i/e (NG/LP)2 RU98 3 RU98 4 RU98 5 RU98 6 RU98Flow rate @ 70°F rise (gpm) 10.8 16.2 21.6 27.0 32.4Flow rate @ 100°F rise (gpm) 7.6 11.4 15.2 19.0 22.8Maximum input rate (Btuh) 398,000 597,000 796,000 995,000 1,194,000<strong>Rinnai</strong> Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-829-1666 • www.rinnai.us4 SP-TRS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!