13.07.2015 Views

Download a datasheet for the AO3 & EA conductivity ... - PVL Ltd

Download a datasheet for the AO3 & EA conductivity ... - PVL Ltd

Download a datasheet for the AO3 & EA conductivity ... - PVL Ltd

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Pressure Vacuum Level Flow Temperature Displays!!!!!!!!!!!!!Liquid Level switch - conductiveF<strong>EA</strong>TURESUp to 4 x 1m long electrodesPolypropylene electrode holder3/4" BSP threadAtmospheric pressure and 60° maxDin rail mounted controllerControls 2 x levels or alarmsSuitable <strong>for</strong> conductive liquidsVery precise level detectionProtection against dry runningPrevents Pump overrunSimple 'Low Cost' installationWide selection of electrodesIntrinsically Safe Option (P5/BAR)TYPE E14 + P4Type P4Type E14Up to 4electrodesmax. length 1mDatafax - 1547TECHNICAL F<strong>EA</strong>TURES FOR E14 ELECTRODE HOLDERAccommodates up to four 1/8" diameter electrodes. Moulded in polypropylene with a screwon cap. Mounting thread is 3/4" B.S.P. and a lock nut is provided. Screwed conduit entry is20mm. All electrodes are plastic coated to prevent tracking. For applications whereexcessive moisture is present, cables may be connected at works and <strong>the</strong> terminals potted.Two spacers are included to separate <strong>the</strong> electrodes (Pt. No. 216).For use at normal atmospheric pressure and temperatures between -20°C and + 60°C. Notsuitable <strong>for</strong> aggressive liquids which attack polypropylene.Page 1 of 2Technical Data- Type E14MaterialSS TypeTitanium316Electrode MaterialS.S.S.S.TitaniumDia. be<strong>for</strong>e Coating1/8" (3.2mm)1/8" (3.2mm)Plastic Coating TypeEpoxy Coated ThermomeltEpoxy Coated FusionBondedEpoxy Coated ThermomeltMax. Length1.0m0.97mPRESSURE-VACUUM-LEVEL LTDUnit 9, Lexden Lodge Industrial Estate, Jarvis Brook,Crowborough, East Sussex, TN6 2EG U.K.Tel: +44(0)1892 66 44 99 Fax: +44(0)1892 66 36 90Web: www.pvl.co.uk Email: info@pvl.co.ukColourBlackGreenBlueE & O E © Pressure-Vacuum- Level <strong>Ltd</strong>Issue -A/03/01


Pressure Vacuum Level Flow Temperature DisplaysLiquid Level switch - conductivePRINCIPLE OF OPERATIONRelies on <strong>the</strong> conducting properties ofliquids to complete an electrical circuitbetween <strong>the</strong> electrode and <strong>the</strong> metaltank. For non-metal or coated tanks, <strong>the</strong>earth path may be through <strong>the</strong> pumppipework. Alternatively, an ear<strong>the</strong>lectrode extending below <strong>the</strong> lowestactive electrode may be fitted. Normallymounted vertically, pressure tightelectrodes are available <strong>for</strong> side entry ifrequired. A low voltage A.C. signal isused on <strong>the</strong> electrodes to preventelectrolysis.TECHNICAL DATA FOR P4 ControllerTechnical Data Type P4 - Conductivity Level ControllerSupplyVoltage110v or 230v 50/60HzAlso 24v or 48v 50/60HzType P4TYPE E14 + P4S upply Tolerance +10% to -20%Type E14Up to 4electrodesmax. length 1mDatafax - 1547Page 2 of 2P ower Consumption 6 vA max.Input(s)Upto 2 level electrodes plusreturn remotely mountedearthAmbientTemperature-10C to + 60CS ensitivit y Adjustable 100 ohms to approx.18,000 ohmsHigher values up to 500,00 ohmsavail.S witching Differential 5% of sensitivity setting (e.g.less than 50 ohms at 1000ohms sensitivity)RelayOutputDouble pole changeover voltagefree contacts. Contacts rated 4A@ 250v A.C. resistiveIndiactionRed L.E.D showing relayenergised. Green L.E.D.'s (2)Failsafe mode and power statusConnections11-pin DIN rail/surface mountin gbase (Optional extra) (8-pin <strong>for</strong>P3)IntrinsicSafetyP5/BAR version when used withzener diode barrier <strong>for</strong>ms anINTRINSICALLY SAFE system(Zone 0)PRESSURE-VACUUM-LEVEL LTDUnit 9, Lexden Lodge Industrial Estate, Jarvis Brook,Crowborough, East Sussex, TN6 2EG U.K.Tel: +44(0)1892 66 44 99 Fax: +44(0)1892 66 36 90Web: www.pvl.co.uk Email: info@pvl.co.ukDistance ofController toelectrodesNominally 100m but greaterdistances using standard cablepossibleE & O E © Pressure-Vacuum- Level <strong>Ltd</strong>Issue -A/03/01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!