13.07.2015 Views

ENERGY RECOVERY VENTILATOR - Venmar

ENERGY RECOVERY VENTILATOR - Venmar

ENERGY RECOVERY VENTILATOR - Venmar

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Dimensions: Kubix ERV (side ports)Ø 4” TYP.1: FRESH AIR TO BUILDING PORT2: EXHAUST AIR FROM BUILDING PORT1163245/16”3 FT.POWER CORD3: FRESH AIR FROM OUTSIDE PORT4: EXHAUST AIR TO OUTSIDE PORTVK0073A15 7/16”19 13/16”2 ³/8”15 1/16”15 5/8”Ventilation PerformanceEXT. STATICPRESSURENET SUPPLYAIR FLOWSUPPLYGROSS AIR FLOWEXHAUSTPA IN. W.G. L/S CFM M³/H L/S CFM M³/H L/S CFM M³/H25 0.1 39 82 139 39 84 143 39 83 14150 0.2 37 78 133 38 80 136 37 79 13475 0.3 35 75 127 36 77 131 35 75 127100 0.4 33 70 119 34 72 122 34 71 121125 0.5 32 67 114 33 69 117 32 67 114150 0.6 29 62 105 30 64 109 29 61 104175 0.7 28 59 100 28 60 102 27 57 97200 0.8 26 55 93 26 56 95 24 52 88Kubix ERV (top ports)15 7 /16”23 FT.POWER CORD13 41: FRESH AIR TO BUILDING PORT2: EXHAUST AIR FROM BUILDING PORT3: FRESH AIR FROM OUTSIDE PORT4: EXHAUST AIR TO OUTSIDE PORTEnergy PerformanceSUPPLYPOWER SENSIBLE APPARENT LATENT <strong>RECOVERY</strong>/NET AIR FLOWTEMPERATURE CONSUMED <strong>RECOVERY</strong> SENSIBLE MOISTUREºC ºF L/S CFM M³/H WATTS EFFICIENCY EFFECTIVENESS TRANSFERHEATING0 32 17 35 60 34 66 77 0.590 32 30 64 109 50 60 69 0.54-25 -13 17 36 61 43 56 75 0.55COOLINGTOTAL <strong>RECOVERY</strong> EFFICIENCY35 95 17 36 61 34 50NOTE: All specifications are subject to change without notice.Ø 4” TYP.18 5 /8”16 5 /16”VK0074A15 1 /16”15 5 /8”2 3 /8”Specifications and Ratings∙ Model: Kubix ERV∙ Part Number top ports: 44112∙ Part Number side ports: 44113∙ Total Assembled Weight (includingpolymerized paper core): 34 lb (15.2 kg)∙ Round 4" ducts∙ Core filters: 2 washable Merv 69.2" x 5.75" x 0.38"(23.4 cm x 16.6 cm x 1 cm)∙ Housing: Pre-painted steel∙ Insulation: Expanded polystyrene∙ Mounting: Suspension by chains andsprings or optional wall bracket∙ Supply & Exhaust Blower Motor: 1 motor- Protection type: Thermally protected- Insulation class: B∙Speed Control on unit: Low & High speed.Other modes available with main andauxiliary wall controls∙ Energy Recovery Core:- Heat Exchange Surface Area:42.3 ft² (3.9 m²)- Type: Crossflow- Material: Polymerized paper∙ Unit Electrical Characteristics:Volts Frequency Ampere Watts120 60 Hz 0.5 60PROJECT:LOCATION:MODEL NO.:QTY.:SUBMITTED BY:DATE:REMARKSResidential Product Group, 550 Lemire Blvd., Drummondville, QC, Canada J2C 7W9 - Tel.: 1-800-567-3855 Fax: 1-800-567-1715www.venmar.caKubixERVd120703

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!