13.07.2015 Views

Dichroic Antenna Reflector for Space Applications CCITT ...

Dichroic Antenna Reflector for Space Applications CCITT ...

Dichroic Antenna Reflector for Space Applications CCITT ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Fig. 10VDU presentation of quality data (per<strong>for</strong>mancemonitoring data)<strong>for</strong>e the traffic over the transmission linksis affected.ZAN202 can collect quality data continuouslyfrom the supervised equipment,whether supplied by Ericsson or other vendors.Ericsson equipment has integratedmodules <strong>for</strong> the interworking with ZAN 202.As regards equipment from other vendors,ZAN 202 has modules that measure theCRC (Cyclic Redundancy Code) and/orFAS (Frame Alignment Signal) at the G.703interfaces.ZAN 202 measures the quality parametersspecified by <strong>CCITT</strong> in RecommendationG.821.- Errored seconds (ES). An ES is one secondduring which one or more bit errorsare detected-Severely errored seconds (SES). AnSES is one second during which BER isgreater than 1 x 10' 3 .-Degraded minutes (DM). A DM is oneminute during which BER is greater than1 x 10 6 , excluding unavailable time measuredas UAS- Unavailable seconds (UAS). A UAS is 10consecutive seconds during which BERis greater than 1 x 10 3 .At the initial level, the above-mentionedquality data is collected by the PUs. Thedata is then fetched by the MMD at certainintervals - the accumulation intervals.These are defined by the operator and maybe between 15 minutes and four hours.MMD-adds all measurement values that havebeen collected during the measurementperiod set by the operator. For example, ifthe accumulation interval is 15 minutesand the measurement period one hour,the MMD will add the measurement valuesfrom four intervals and give "onehour"values- compares the measurement values withpreset threshold values stored in theMMD. An alarm is generated if the thresholdvalue <strong>for</strong> any G.821 parameter is exceeded.Two threshold values and two measurementperiods may be defined <strong>for</strong> each qualityparameter. One threshold value marksthe boundary between "good" and "deteriorated"quality and the other between"deteriorated" and "unacceptable" quality.Completed measurement results are presentedon a VDU or printer. Fig. 10 showsan example of a quality parameter display.Man-machine interfaceVisual display units of type VT100 are used<strong>for</strong> man-machine communication. Upto sixVDUs may be connected to an MMD, eitherdirectly via V24/V28 interfaces or via standardmodems. A printer may also be connected.Alarms and other in<strong>for</strong>mation maybe presented on one or several of the I/Odevices. ZAN 202 permits three differentuser categories. A unique password can bedefined <strong>for</strong> each category.REQUEST PM DATAEQP IDENTITYPRESENTATIONPM TEMPLATEACCUMULATIONSTART TIMEAPR-10 08:00APR-10 09:00APR-10 10:00APR-10 11:00APR-10 12:00APR-10 13:00APR-10 14:00PM HISTORY DATAINTERVALLENGTH00 01:0000 01:0000 01:0000 01:0000 01:0000 01:0000 01:00APR-10 00:00 00 14:00APR-09 00:00 01 00:00EDBG,LT140,4PERCENTAGE VALUES6DM1.6600003.333.330.00360.0013PM-PARAMETERSES SES0.056 00.028 00.028 00 00.028 04.326 0.4443.753 0.5550.01240.00280.00120.00031991-APR-10 15:11UAS000000.1130.089BER1E-082E-093E-09

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!