Input rativariationsMomentary voltagedip capability (*6)Required powerVariable Torquesupply capacity[kVA] (*7)Operation will continue with 165V or more. If voltage drops below 165V, operation will continue for up to 15 ms.If "Continuous operation" is selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.0.4 0.7 1.3 2.2 3.1 5 5 7.2 9.7 15 20 24 29 29 38 47 56 69 93 111<strong>EQ5</strong> AC Drive Operations ManualOutputratingsInput ratingsInput ratings<strong>EQ5</strong> VT (Variable Torque) – 230V <strong>Series</strong><strong>EQ5</strong> CT (Constant Torque) – 460V <strong>Series</strong>Applied <strong>Motor</strong> Type 0.25 0.5 1 2 NEMA 3 1 5 7.5 10 15 20 25 30 30 PROTECTED 40 50 CHASSIS 60 75 100 125 150Nominal (HP)Applied <strong>Motor</strong>0.5 1 2 3 5 5 7.5 10 15 20 25 30 30 40 50 60 75 100 125 150 200 250 300 350 350 400 450 500 600Nominal Model (HP)0P2 0P5 001 002 003 005 007 010 015 020 025 030 032 040 050 060 075 100 125 150<strong>EQ5</strong>-2XXX-XXModel-N10P5 001-N1002-N1003 005-N1007-N1010 015-N1020-N1025-N1030 032-N1040-N1050 060-N1075-N1100-N1125 150-C200 250-C300-C350 400-C450-C500 600-C700 800-CRated <strong>EQ5</strong>-4XXX-XX output -N10.6-N11.2-N12.0-N1 -N13.2-N14.4-N1 -N16.8-N18.8-N112-N1 -N117-C22-C -C27-C31-C35-C -C46-C -C58-C72-C -C86-C113-C -C138-C -C165capacity Rated [kVA] output (*1)Rated1.2 2.0 2.9 4.4 7.2 7.2 10 14 19 24 31 36 36 48 60 73 89 120 140 167 202 242 300 331 331 414 466 518 590capacity output [kVA] (*1)1.5 3.0 5.0 8.0 11 17 22 29 42 55 68 80 87 115 145 180 215 283 346 415current Rated [A] output (*2)Overload1.5 2.5 3.7 5.5 9 9 13 18 24 30 39 45 45 60 75 91 112 150 176 210 253 304 377 415 415 520 585 650 740current [A] (*2)110% of rated output current for 1 min.capability Overload150% of rated output current for 1 min.150% of rated output current for 1 min.Starting capability torque 200% of rated output current for 0.5 s180% 50% of rated or more output current for 0.5 sRated Starting output torque minimum 200% (torque vector control mode) minimum 180% (torque vector control mode)3-phase, 200V/50Hz, 200V,220V,230V/60Hzvoltage Rated [V] output (*3)Rated3-phase, 380V, 400V, 415V(440V)/50Hz, 380V, 400V, 440V, 460V/60HzVoltage output [V] (*3)50,60Hzfrequency Rated output [Hz]50,60HzPhases, frequency voltage, [Hz]3-phase,200 to 230V, 50/60Hz3-phase, 200 to 230V, 50/60Hzfrequency Phases, voltage,Voltage/frequency3-phase,380 to 480V,50/60Hz 3-phase, 380 to 440V, 50/60Hz (*5)Voltage: +10% to -15% (Imbalance rate between phases: 2% or less) (*5) , Frequency: +5% to -5%variations Voltage/frequencyMomentaryVoltage: +10% to -15% (Imbalance rate between phases: 2% or less) (*5) , Frequency: +5% to -5%variations voltage Operation will continue with 165V or more. If voltage drops below 165V, operation will continue for up to 15 ms.dip Momentary capability (*6) If "Continuous operation" is selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.Operation will continue with 310V or more. If voltage drops below 310V, operation will continue for up to 15 ms.Required voltage power dipIf "Continuous operation" is selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.supply capability capacity (*6) 0.4 0.7 1.3 2.2 3.1 5 7.2 9.7 15 20 24 29 29 38 47 56 69 93 111 139[kVA] Required (*7) powersupply capacity 0.7 1.2 2.2 3.1 5.0 5.0 7.2 9.7 15 20 24 29 29 38 47 57 70 93 111 136 161 196 244 267 267 341 383 433 488[kVA] (*7)Outputratings<strong>EQ5</strong> VT (Variable Torque) – 460V <strong>Series</strong>_________________________________________________________________________Type NEMA 1 PROTECTED CHASSIS<strong>TECO</strong> – <strong>Westinghouse</strong> <strong>Motor</strong> <strong>Company</strong> Standard Specifications Notes con’t 104Applied <strong>Motor</strong>Nominal (HP)OutputratingsInput ratingsType NEMA 1 PROTECTED CHASSIS*See notes 1 - 7 on the next pages.Model<strong>EQ5</strong>-4XXX-XXRated outputcapacity [kVA] (*1)Rated outputcurrent [A] (*2)OverloadcapabilityStarting torqueRated outputvoltage [V] (*3)Rated outputfrequency [Hz]Phases, voltage,frequencyVoltage/frequencyvariationsMomentaryvoltage dipcapability (*6)Required powersupply capacity[kVA] (*7)0.5 1 2 3 5 7.5 10 15 20 25 30 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600 700 8000P5 001 002 003 005 007 010 015 020 025 030 032 040 050 060 075 100 125 150 200 250 300 350 400 450 500 600 700 800-N1 -N1 -N1 -N1 -N1 -N1 -N1 -N1 -N1 -N1 -N1 -N1 -C -C -C -C -C -C -C -C -C -C -C -C -C -C -C -C -C1.2 2.0 2.9 4.4 7.2 10 13 18 24 29 35 36 48 60 73 89 120 140 167 202 242 300 331 386 414 518 590 669 7651.5 2.5 3.7 5.5 9 12.5 16.5 23 30 37 44 45 60 75 91 112 150 176 210 253 304 377 415 485 520 650 740 840 960110% of rated output current for 1 min.50% or more3-phase, 380V, 400V, 415V(440V)/50Hz, 380V, 400V, 440V, 460V/60Hz50,60Hz3-phase,380 to 480V,50/60Hz 3-phase, 380 to 440V, 50/60Hz (*4)Voltage: +10% to -15% (Imbalance rate between phases: 2% or less) (*5) , Frequency: +5% to -5%Operation will continue with 310V or more. If voltage drops below 310V, operation will continue for up to 15 ms.If "Continuous operation" is selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.0.7 1.2 2.2 3.1 5.0 7.2 9.7 15 20 24 29 29 38 47 57 70 93 111 136 161 196 244 267 341 383 433 488 549 610(*1) Indicated capacities are at the rated output voltage 230V for the 230V series and 460V for the 460V series. The rated capacity will be lowered if thesupply voltage is lower.(*2) In the case of a low impedance load, such as a high-frequency motor, the current may drop below the rated value.(*3) The output voltage cannot exceed the input From supply note voltage. (*5) on previous page:( Max. Voltage [V] - Min. Voltage [V] )Imbalance rate between phases [%] =3-phase average voltage [V]x 67[%]_________________________________________________________________________<strong>TECO</strong> – <strong>Westinghouse</strong> <strong>Motor</strong> <strong>Company</strong> Standard Specifications Notes con’t 105Cont.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!