13.07.2015 Views

warning - Nordyne

warning - Nordyne

warning - Nordyne

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VENT TERMINAL AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTEDA = Clearance above grade, veranda, porch,deck, or balconyB = Clearance to window or door that may beopenedCanadian Installations 1 US Installations 212 inches (30 cm) 12 inches (30 cm)6 inches (15 cm) for appliances 10,000Btuh (3 kW), 12 inches (30 cm) forappliances > 10,000 Btuh (3 kW) and100,00 Btuh (30 kW), 36 inches (91 cm)for appliances >100,00 Btuh (30 kW)4 feet (1.2 m) below or to side of opening;1 foot (300 mm) above openingC = Clearance to permanently closed window * *D = Vertical clearance to ventilated soffitlocated above the terminal within ahorizontal distance of 2 feet (61 cm) fromthe center line of the terminal* *E = Clearance to unventilated soffit * *F = Clearance to outside corner * *G = Clearance to inside corner * *H = Clearance to each side of center lineextended above meter/regulator assembly3 feet (91 cm) within a height 15 feetabove the meter/regulator assemblyI = Clearance to service regulator vent outlet 3 feet (1.83 m) *J = Clearance to nonmechanical air supply inletto building or the combustion air inlet to anyother appliance6 inches (15 cm) for appliances 10,000Btuh (3 kW), 12 inches (30 cm) forappliances > 10,000 Btuh (3 kW) and100,00 Btuh (30 kW), 36 inches (91 cm)for appliances >100,00 Btuh (30 kW)*4 feet (1.2 m) below or to side of opening;1 foot (300 mm) above openingK = Clearance to a mechanical air supply inlet 6 feet (1.83 m) 3 feet (91 cm) above if within 10 feet(3 m) horizontallyL = Clearance above paved sidewalk or paved 7 feet (2.13 m) † 7 feet (2.13 m)driveway located on public propertyM = Clearance under veranda, porch deck, or 12 inches (30 cm) ‡balcony*1In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code2In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves bothdwellings.‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor.* For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA B149.1, one of the following statement shall be included:“Clearance in accordance with local installation codes, and the requirements of the gas supplier and themanufacturer’s installation instructions.”Figure 20. Vent Termination Clearances for Other Than Direct Vent Furnaces24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!