13.07.2015 Views

324 - Audi A6 2005 - VolksPage.Net

324 - Audi A6 2005 - VolksPage.Net

324 - Audi A6 2005 - VolksPage.Net

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The functionality of the solenoid valve forServotronic is also used in the <strong>A6</strong>’05 for the firsttime to reduce the thermal load on the steeringpump.The highest thermal load on the pump occurs whenthe steering is held at the limit position. The endposition of the piston in the steering gear is thenreached, but the pump continues to supply oil.This increases the pressure until the pressurecontrolvalve in the pump opens. The pump thenfeeds via short circuit. This means that the suppliedoil travels back to the intake side of the pump theshort way via the pressure-control valve. Thisincreases the oil temperature significantly in a shortspace of time.Pressure-control valve opensPiston in end position<strong>324</strong>_04641

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!