13.07.2015 Views

Industrial Ethernet

Industrial Ethernet

Industrial Ethernet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IntroductionActive componentsBECO-LineEMC Shock- & vibration-test Environment-testEN 61000-4-2 (ESD) 6kV/8kVEN 61000-4-3 (radiated immunity)ENV 50204 @AM 10V/average 80MHz - 1,0GHzIEC 60068-2-1 & IEC 60068-2-2operating 0°C ... 60°Cnon operating -40°C ... 85°CEN 61000-4-4 (burst) ~ 2kV; 2kV; I/O 1kVEN 61000-4-5 (surge) 2/1kVEN 61000-4-6 (conducted immunity)ENV 50204 @10V 150kHz - 80MHzEN 61000-4-11 (voltage variation)EN 55022 (HF E)conducted emissions 150kHz - 30MHzradiated emissions 30MHz - 1GHz pp/averageradiated emissions 30MHz - 1GHz pp/qpAdvancedLine unmanagedEMC Shock- & vibration-test Environment-testEN 61000-4-2 (ESD) 6kV/8kVEN 61000-4-3 (radiated immunity)ENV 50204 @AM 10V/average 80MHz - 1GHzEN 61000-4-4 (burst) ~ 2kV; 2kV; I/O 1kVEN 61000-4-5 (surge) 2/1kVEN 61000-4-6 (conducted immunity)ENV 50204 @10V 150kHz - 80MHzEN 61000-4-11EN 61000-4-29 (voltage variation)EN 55022 (HF E)conducted emissions 150kHz - 30MHzradiated emissions 30MHz - 1GHz pp/averageradiated emissions 30MHz - 1GHz pp/qpIEC 60068-2-6 sinusoidal vibrationsfrequencies: 5-9 Hz, amplitude: 3.5 mmfrequencies: 9-150 Hz, acceleration: 1gIEC 60068-2-27 shock test, half-sinusoidalshock acceleration: 15g (operating) 30g (non operating)shock period: 11msIEC 60068-2-1 & IEC 60068-2-2operating -40°C ... 75°Cnon operating -40°C ... 75°CIEC 60068-2-14 thermal shockoperating 0°C ... 60°Cnon operating -40°C ... 80°CIEC 60068-2-30 damp heatAdvancedLine managedEMC Shock- & vibration-test Environment-testEN 61000-4-2 (ESD) 6kV/8kVEN 61000-4-3 (radiated immunity)ENV 50204 @AM 10V/average 80MHz - 1GHzEN 61000-4-4 (burst) ~ 2kV; 2kV; I/O 1kVEN 61000-4-5 (surge) 2/1kVEN 61000-4-6 (conducted immunity)ENV 50204 @10V 150kHz - 80MHzEN 61000-4-11EN 61000-4-29 (voltage variation)EN 55022 (HF E)conducted emissions 150kHz - 30MHzradiated emissions 30MHz - 1GHz pp/averageradiated emissions 30MHz - 1GHz pp/qpIEC 60068-2-6 sinusoidal vibrationsfrequencies: 5-9 Hz, amplitude: 3.5 mmfrequencies: 9-150 Hz, acceleration: 1gIEC 60068-2-27 shock test, half-sinusoidalshock acceleration: 15g (operating) 30g (non operating)shock period: 11msIEC 60068-2-1 & IEC 60068-2-2operating -40°C ... 75°Cnon operating -40°C ... 75°CIEC 60068-2-14 thermal shockoperating 0°C ... 60°Cnon operating -40°C ... 80°CIEC 60068-2-30 damp heatMedia ConverterEMC Shock- & vibration-test Environment-testEN 61000-4-2 (ESD) 6kV/8kVEN 61000-4-3 (radiated immunity)ENV 50204 @AM 10V/average 80MHz - 1GHzEN 61000-4-4 (burst) ~ 2kV; 2kV; I/O 1kVEN 61000-4-5 (surge) 2/1kVEN 61000-4-6 (conducted immunity)ENV 50204 @10V 150kHz - 80MHzEN 61000-4-11EN 61000-4-29 (voltage variation)EN 55022 (HF E)conducted emissions 150kHz - 30MHzradiated emissions 30MHz - 1GHz pp/averageradiated emissions 30MHz - 1GHz pp/qpIEC 60068-2-6 sinusoidal vibrationsfrequencies: 5-9 Hz, amplitude: 3.5 mmfrequencies: 9-150 Hz, acceleration: 1gIEC 60068-2-27 shock test, half-sinusoidalshock acceleration: 15g (operating) 30g (non operating)shock period: 11msIEC 60068-2-1 & IEC 60068-2-2operating -40°C ... 75°Cnon operating -40°C ... 75°CIEC 60068-2-14 thermal shockoperating 0°C ... 60°Cnon operating -40°C ... 80°CIEC 60068-2-30 damp heatB.6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!