Switches with management functionsWaveLine managed switches with IOsActive componentsOur WaveLine switches come optionally with two digital IOs (inputand output). After the IOs are configured, network parameters canbe monitored with the managed switch. An uninterruptible powersupply (UPS) can also be connected to the IOs. If the supplyvoltage fails, the switch changes over to the battery on the UPS.The signal output wired to the WaveLine managed switch canissue an SNMP trap to a Scada system running on a networkserver. In addition, the IO output activates an alarm light on theoutside of the electrical cabinet so that the power outage can beeasily seen. No PLC is required.BProduction facilityProduction facilityUninterruptiblepower supplySNMP TrapDigitalInputDigitalOutputAlarm lightB.29