13.07.2015 Views

60-982 LXI Wired Trigger Bus Adaptor - Pickering Interfaces

60-982 LXI Wired Trigger Bus Adaptor - Pickering Interfaces

60-982 LXI Wired Trigger Bus Adaptor - Pickering Interfaces

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>60</strong>-<strong>982</strong><strong>LXI</strong> <strong>Wired</strong> <strong>Trigger</strong> <strong>Bus</strong> <strong>Adaptor</strong><strong>Wired</strong> <strong>Trigger</strong> <strong>Bus</strong> <strong>Adaptor</strong><strong>60</strong>-<strong>982</strong>●●●●●●●Converts LVTTL to WTB SignalsConverts WTB to LVTTL SignalsSupports all Modes of WTB OperationManual or Remote ConfigurationInternally Terminated And Thru Line VersionsSupports All 8 <strong>LXI</strong> WTB ChannelsIdeal Solution For Adapting non <strong>LXI</strong><strong>Trigger</strong>ing to <strong>LXI</strong>The <strong>60</strong>-<strong>982</strong> provides a effective method of adaptingtrigger signals from bench instruments to the <strong>LXI</strong> <strong>Wired</strong><strong>Trigger</strong> <strong>Bus</strong> signalling standard. The <strong>60</strong>-<strong>982</strong> convertsM-LVDS signals on the WTB to Low Voltage TTL signalsand converts Low Voltage TTL signals to M-LVDS. All8 channels of the <strong>LXI</strong> WTB are supported in a singleadaptor.Each channel of the WTB can be configured eithermanually or through a digital I/O to be Disabled, Drivenor in <strong>Wired</strong> OR mode. The interface is fully compatiblewith the <strong>LXI</strong> WTB standard and counts as one node onthe bus.The adaptor is available in two versions, one havinga thru line connection for the WTB and the secondincluding a terminator.The <strong>60</strong>-<strong>982</strong> is an ideal solution to integrating productswith dedicated trigger facilities, such as oscilloscopes,spectrum analyzers or signal generators, into <strong>LXI</strong>systems using the WTB.Power for the <strong>60</strong>-<strong>982</strong> is provided by an external AC/DCadaptor or DC power supply.WTBConnectorM-LVDSInterfaceM-LVDSInterfaceInputOutputInputOutputInputOutput<strong>LXI</strong> 0<strong>LXI</strong> 1<strong>LXI</strong> 2WTBConnectorWTBTerminationInputOutputInputOutputInputOutput<strong>LXI</strong> 0<strong>LXI</strong> 1<strong>LXI</strong> 2InputOutput<strong>LXI</strong> 3InputOutput<strong>LXI</strong> 3InputOutput<strong>LXI</strong> 4InputOutput<strong>LXI</strong> 4InputOutput<strong>LXI</strong> 5InputOutput<strong>LXI</strong> 5InputOutput<strong>LXI</strong> 6InputOutput<strong>LXI</strong> 6InputOutput<strong>LXI</strong> 7InputOutput<strong>LXI</strong> 7WTBConnectorDigital I/O ConfigurationManual ConfigurationFunctional Diagram for <strong>60</strong>-<strong>982</strong>-001With Thru Line Connection for WTBDigital I/O ConfigurationManual ConfigurationFunctional Diagram for <strong>60</strong>-<strong>982</strong>-002With Internal TerminationISSUE 3.1 JAN 2008<strong>LXI</strong> Switch & Instrumentation<strong>Pickering</strong> <strong>Interfaces</strong> www.pickeringtest.com


Terminator<strong>Wired</strong> <strong>Trigger</strong> <strong>Bus</strong><strong>60</strong>-<strong>982</strong><strong>Adaptor</strong>Thru-LineTerminatorSafety & CE ComplianceAll modules are fully CE compliant and meet applicable EUdirectives: Low-voltage safety EN61010-1:2001,EMC Immunity EN61000-6-1:2001, Emissions EN55011:1998.<strong>LXI</strong>Device1<strong>LXI</strong>Device2<strong>LXI</strong>Device3Product Order Codes<strong>LXI</strong> WTB <strong>Adaptor</strong>, Thru Line<strong>LXI</strong> WTB <strong>Adaptor</strong>, Terminated<strong>60</strong>-<strong>982</strong>-001<strong>60</strong>-<strong>982</strong>-002Terminator<strong>LXI</strong>Device1<strong>Wired</strong> <strong>Trigger</strong> <strong>Bus</strong> <strong>60</strong>-<strong>982</strong><strong>Adaptor</strong>Terminated<strong>LXI</strong>Device2<strong>LXI</strong>Device3Mating Connectors & CablingExamples of cabling available for the <strong>60</strong>-<strong>982</strong> are:40-977-511-1M40-978-701-1MCable, 50Ω SMB, Plug to Plug,1 Meter Length.Cable, 50Ω SMB Plug to 50Ω BNCPlug, 1 Meter Length.Please refer to the <strong>Pickering</strong> <strong>Interfaces</strong> “InterconnectionSolutions” catalog for a full list of connector/cablingoptions, including drawings, photos and specifications.This is available in either print or as a download.Typical application for the Thru Line and Terminatedversions of the <strong>60</strong>-<strong>982</strong> <strong>LXI</strong> WTB AdapterSpecification<strong>LXI</strong> WTB Connectors:25-way Micro D connectorsconformant to <strong>LXI</strong> standard.<strong>60</strong>-<strong>982</strong>-001 uses one connector.<strong>60</strong>-<strong>982</strong>-002 uses two connectorswith thru line connections tomatch to WTB.<strong>LXI</strong> WTB Termination: Included in <strong>60</strong>-<strong>982</strong>-001conformant to <strong>LXI</strong> Standard. WTBmust be externally terminated for<strong>60</strong>-<strong>982</strong>-002.I/O Signals:<strong>LXI</strong> WTB Loading<strong>LXI</strong> WTB Mode:Power Requirements:Physical Size:Inputs and outputs on SMBconnectors. LVTTL (3.3V) signallevels.Input impedance: 10kΩ nominalOutput impedance: 50Ω nominalMinimum load impedance: 50ΩMinimum recommended pulsewidth is 10ns.Equivalent to the load of one <strong>LXI</strong>Device.Each channel selectable to beDisabled, Driven, or <strong>Wired</strong> ORthrough manual configuration withDIP switches. Can be remotelycontrolled through digital I/O porton 25-way D-type connector.Requires 6V DC at 500mA.Supplied with universal AC/DC<strong>Adaptor</strong>, 500 mA complete withUK, USA and European supplyadaptors.100mm long84mm wide30mm highLatest DetailsPlease refer to our Web Site for Latest Product Details.www.pickeringtest.comOperating/Storage ConditionsOperating ConditionsOperating Temperature:Humidity:Altitude:Storage and Transport ConditionsStorage Temperature:Humidity:Altitude:<strong>LXI</strong> is the new standardfor Ethernet control ofinstrumentation. It is thenatural successor to GPIB(IEEE-488) incorporatingLAN connectivity, full webbrowser support, IVI driversand advanced triggeringcapability.0°C to 55°CUp to 95% non-condensing5000m-20°C to +75°CUp to 95% non-condensing15000m<strong>Pickering</strong> <strong>Interfaces</strong> is aBoard level member of the<strong>LXI</strong> Consortium (www.lxistandard.org) and togetherwith Agilent Technologies was the first companyto release a fully compliant <strong>LXI</strong> device. <strong>Pickering</strong> isdeveloping a large range of products conforming tothe <strong>LXI</strong> standard and is constantly introducing newproducts in response to specific user demand. Forfurther information go towww.pickeringtest.com/lxi© Copyright (2007) <strong>Pickering</strong> <strong>Interfaces</strong>. All Rights Reserved<strong>Pickering</strong> <strong>Interfaces</strong> maintains a commitment to continuous product development, consequently we reserve the right to vary from the description given in this data sheet.<strong>Pickering</strong> <strong>Interfaces</strong> are Strategic Level members of the <strong>LXI</strong> Consortium www.lxistandard.orgwww.pickeringtest.comE-Mail sales@pickeringtest.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!