13.07.2015 Views

Model: PURY-P168TSKMU-A - Mitsubishi Electric Sales Canada Inc.

Model: PURY-P168TSKMU-A - Mitsubishi Electric Sales Canada Inc.

Model: PURY-P168TSKMU-A - Mitsubishi Electric Sales Canada Inc.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Module :<strong>PURY</strong>-P72TKMU-A – DIMENSIONS<strong>PURY</strong>-P72,96TKMU-A(-BS)Note 1.Please refer to the next page for informationregarding necessary spacing around theunit and foundation work.2.At brazing of pipes,wrap the refrigerant service valvewith wet cloth and keep the temperature ofrefrigerant service valve under 120°C(248°F).Connecting pipe specificationsDiameterService valveRefrigerant pipe<strong>Model</strong>LowpressureHighpressureLowpressureHighpressure<strong>PURY</strong>-P72TKMU ø15.88 Brazed ø19.05 Brazed ø25.4 ø25.4(5/8) *1 (3/4) *1 (1)(1)<strong>PURY</strong>-P96TKMU ø19.05 Brazed ø22.2 Brazed ø25.4 ø25.4(3/4) *1 (7/8) *1 (1)(1)*1 Use the pipe joint(field supply) and connect to the refrigerant service valve piping.SpecificationsUsageNO.140 × 77 Knockout hole(5-17/32) (3-1/16)Front through holeFront through hole1ø45 Knockout hole(1-25/32)(Uses when twinningkit (optionalparts) is mounted.)For pipesBottom through hole150 × 94 Knockout hole(5-29/32) (3-23/32)Front through hole ø62.7 or ø34.5 Knockout hole(2-15/32) (1-3/8)Front through hole ø43.7 or ø22.2 Knockout hole(1-3/4) (7/8)For wiresBottom through hole ø65 Knockout (2-9/16)holeBottom through hole ø52 Knockout (2-1/16)holeFor transmission cables Front through hole ø34 Knockout (1-11/32)hole29.5(1-3/16)(26-13/16)681(678~684)(26-23/32~26-15/16)(Mounting pitch)(7-23/32)(5-3/4)(4-25/32)146(5-3/4)94 84(3-23/32) (3-5/16)29.5(1-3/16)(8-9/16)(5-23/32)(10-11/32)2020(9-5/16) 236 75(2-31/32)(13/16) (13/16)586(23-3/32) 57(9-29/32) 251 58(2-5/16)(2-1/4)(10-23/32) 272 140(5-17/32)Left side view Front view(10-23/32) (11-7/8) (8-15/16) 272 301 227150(5-29/32)83(3-9/32)2(3-5/32) (Mounting pitch) (3-5/32)34Unit : mm(in.)(2-5/32)89 77(3-17/32) (3-1/16)303(11-15/16)(23-5/8)(2-25/32) =(5-29/32)X4600=150×4Intakeair57(2-1/4)Discharge air19.5(25/32)19.5(25/32)1181(46-1/2)1220(48-1/16)Top view54(740)(29-5/32)1961461212171452621347(53-1/16)1650(64-31/32)70150(5-29/32)740(29-5/32)4X5-ø4.6(3/16) Hole(Make hole at the plastic fan guardfor snow hood attachment)Control boxRefrigerant service valveRefrigerant service valveIntakeair4 5267Refrigerant servicevalve 381Refrigerant servicevalve IntakeairServicepanel2X2-80(3-5/32)X35(1-13/32) Oval hole2X2-14(9/16)X20(13/16) Oval hole80 1060(41-3/4)Bottom view805678

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!