The End for High-Pressure Gas Cylinders?High-pressure gas cylinders are acommon sight in many laboratories:a default for supplying analyticalinstruments with their gas requirements,high-pressure gas cylinders are familiarand provide the gas that’s required, so itcould be said that the old adage, ‘if it isn’tbroke, don’t fix it’, could well apply.Despite this, increasing numbers ofanalytical instrument users are choosingto supply their GC FID, LC/MS andother types of instrument with gas viaan analytical gas generator. Driving thisdecision will be a combination of factorsbroadly grouped into four areas; safety,cost, convenience and purity.Safety Concerns…High-pressure gas cylinders can provokesafety concerns in a number of differentways, some with potentially fatalconsequences. The presence of highpressuregas cylinders in the laboratoryhas been likened to sharing the laboratorywith a potential missile. This stems fromthe behaviour of a cylinder that suddenlyde-pressurises. There is enough forcereleased with a European ‘L’ size cylinderto accelerate the cylinder to somethinglike 66mph or 108km/h in around 1/10seconds. Cylinders weigh in at 200lb(98kg), so there’ll be enough momentumto cause some severe damage.It’s because of this potential ‘missilescenario’ that cylinders tend to bestrapped down to something fixed.Even restrained, should a large cylindersuddenly vent its contents into thelaboratory, then there are potentiallyfatal consequences. For example, ifa high-pressure cylinder of nitrogensuddenly vented into the atmosphere ofa laboratory, then more than 9,000 litresof un-breathable gas would be released.This would dramatically reduce theoxygen content of the air – presentingthe possibility of asphyxiation. Therisk of oxygen displacement from theatmosphere is also associated withliquefied gases whose volume willincrease as much as 1,000 fold when inthe gas phase. This means liquid nitrogendewars can also be hazardous.If the gas suddenly venting was apotentially explosive gas, as in the case ofhydrogen, the result could be much moredramatic. Hydrogen will form an explosivemixture at just 4% volume in air.These possibilities are the life threateningsafety concerns associated with highpressuregas cylinders. However, thereis still the potential for other non-fatalinjuries. The practice of rolling cylinderson their bottom edge comes with the riskof trapping toes or feet. With the ‘smaller’cylinders there is also potential for heavylifting injuries when being placed on abench top.Costs Increase Whilst Convenience andPurity are Reduced…With high pressure cylinders the storagerequirements are dictated by safetyconcerns, such as separating hydrogencylinders and cylinders of oxidising gases.These often result in cylinders being somedistance from where the gas is used andhence long gas lines. Whilst the longergas lines result from the positioning ofcylinders for safety concerns, the impactwill be in the areas of cost, convenienceand purity.With any gas line there is the potential forleaks, and the longer the line the greaterthe potential. Hence the requirement to<strong>regula</strong>rly leak-check the gas supply line– this both increases costs and decreasesconvenience - whilst leaks allow gas toescape and also allow impurities to enterthe gas supply, which reduces purity andinfluences the accuracy of any analysis.A Smarter Choice…Analytical gas generators can remove therequirement for high-pressure cylindergases for many analytical instrumentusers. Analytical gas generators aretypically placed next to the instrumentthey’re servicing. This removes any needfor extended gas lines and with themassociated problems impacting on purity,cost and convenience.There are inherent features both in thedesign and the way in which generatorsoperate which offer clear compellingreasons to switch from high-pressuregas cylinders. The latest gas generatorsutilise new technologies includingadsorbents, catalysts, and specialistmicro dryers, to produce ultra high puritygases. Generators are designed to beused at the point of use, simplifying andminimising the amount of pipe work,and guaranteeing ultra high purity gasreaching the instrument.The generators are designed to runcontinuously with minimal annualmaintenance and therefore minimaldisruption to the gas supply. This all buteliminates the introduction of impurities,which can be reduced further by theinstallation of in line purifiers.Increased Safety…High-pressure gas cylinders will containgas which is at a pressure of 200 to 300times atmospheric pressure, and gaswhich is released to atmospheric pressurewould have a volume in the region of9,000 litres. Analytical gas generatorsoperate at a fraction of this pressureand have very low volumes of stored gaswithin them. One of Parker domnickhunter’s market leading hydrogengenerators, for example, will have just50 ml of stored gas, which will be at amaximum of around 5 times atmosphericpressure. Hence the missile concern isremoved with a generator, and there’sno large volume of gas to suddenly ventand make the atmosphere potentiallyexplosive or deficient of life-supportingoxygen. Additional safety features are alsoincorporated in the design; for example,in Parker domnick hunter hydrogengenerators there are leak detection autoshut-off devices.Increased Convenience…High-pressure gas cylinders will require<strong>regula</strong>r replacement. Gas cylindersrunning out part way through analysiswill result in unplanned downtime,and a replacement cylinder has to becollected and the old one removed whichbrings manual handling and safetyconcerns. After the new cylinder has beenconnected restarting the instrument,and waiting for stable baseline and


(continued)re-calibration, are required beforesamples can be run. Life is moreconvenient with a gas generator as there’sno unplanned downtime. Analytical gasgenerators only require simple quickmaintenance which can be planned for– they don’t unexpectedly run-out of gashalfway through analysis.Increased Purity…Analytical gas generators provide aconstant source of gas. This removes thevariations in purity between cylinders,helping to improve sensitive analyses.Purity is also preserved because there isno chance for impurities to enter the gaspipes, which may happen as cylinders areswitched and <strong>regula</strong>tors changed-over.Reduced Cost…High-pressure gas cylinders can alsoprove to be costly: typical payback periodsfor analytical gas generators are short –sometimes less than one year. The cost ofusing high pressure cylinders is not justthe cost of the gas itself but other charges,some of which can be seen and otherswhich are hidden. Cylinder rental anddelivery charges are readily apparent,however there’s also hidden costs. Thesemust also be included to reveal the truecost.Unlike cylinders, Analytical Gas Systemshave no hidden costs. There are norecurring costs with generators foractivities such as ordering replacementcylinders, there are no storage costs forthe spare and empty cylinders, and thereis no cost of lost productivity through theneed to stop and replace cylinders.Innovative Technology…Parker domnick hunter analytical gasgenerators are world renowned for theirreliability, dependability and long life.Since commercializing their firstlaboratory scale analytical gas generatorin the 1980s, Parker domnick hunter nowserve an installed customer base of over40,000 gas generator users globally.Part of the reason behind this is theunique innovative technology employedin Parker domnick hunter generators,from carbon molecular sieve, to the use ofrobust hydrogen membranes.A Smarter Choice for LC/MS…Providing nitrogen for uses such as LC/MS, Parker domnick hunter’s pressureswing adsorption nitrogen generatorsrepresent state-of-the-art technology.The carbon molecular bed simply andefficiently separates compressed air intonitrogen. The carbon molecular bedachieves this due to its selectiveadsorption capabilities for different gases– oxygen and other unwanted constituentsof the compressed air are simply removedby desorption – the complete process ismonitored by a sophisticated controlsystem.These generators, when connected to anexisting compressed air supply, willprovide a constant supply of nitrogen withlimited moving parts inside the generator.This means that the generator is very quietwhilst operating and there are minimalreplacement parts.A Smarter Choice for GC…Hydrogen offers advantages for GC userswhen used as a carrier gas. The VanDeemter curves illustrate the wide rangeover which high efficiency is obtained,making hydrogen the best carrier gas forsamples containing compounds whichelute over a wide temperature range. Therisks associated with high-pressure gascylinders have already been outlined –hence a gas generator is the smarterchoice for hydrogen. The optimiseddesign of Parker domnick hunterhydrogen generators take deionised waterand, through electrolysis, separate thehydrogen. This is then purified usingdesiccants, and specialist micro dryers.An End For Cylinders?With the improvements that gasgenerators offer in the areas of safety,purity, convenience and cost there’s littlereason to use high-pressure gas cylinderswith instruments such as GC and LC/ MS.The range of Parker domnick hunteranalytical gas generators also extends itstechnologically innovative approach toother techniques such as FT-IR, TOC, ICP,ELSD and Atomic Absorption.


Gas Generatorsfor GC and GC/MS


Product Information SheetHydrogen Generatorsfor GC combustion detector applicationsThe Parker domnick hunter H high purity hydrogengas generators offer the optimum combination ofsafe operation, reliability and performance.Utilising field proven PEM cell technology,hydrogen is produced on demand from deionisedwater and electricity, at low pressure and withminimal stored volume. Innovative control softwareallows unrivalled operational safety and reliability.The H generators ideally supply fuel gas to allknown GC combustion detectors used in today’slaboratory workflows. Three models operate at flowrates; 160 ml/min, 250 ml/min and 500 ml/min.Hydrogen generators are available with RemoteNetworking software. RemoteNet allows up to27 hydrogen generators to be actively controlledfrom one central PC, and facilitates true cascadingcapabilities.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Eliminate dangerous hydrogen cylinders fromthe work place• Simple to install and operate• Compact, reliable with minimal maintenance• Produces a continuous supply of 99.9995%pure hydrogen at up to 6.9 bar• 2 year standard cell warranty• Optional automatic water fill and remotenetworking capabilityENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RatePurity*Water Consumption(24/7, full flow)Delivery Pressureml/min % L/week bar g psi gOptional AutoWater Fill (AWF)20H 160 >99.9995 1.25 0.3-6.89 5-100 YES40H 250 >99.9995 2 0.3-6.89 5-100 YES60H 500 >99.9995 4 0.3-6.89 5-100 YES*With respect to oxygenNote: For auto water fill option add suffix AWF ie 20H-AWFTechnical DataAmbient Temperature RangeWater Supply Pressure*Water Supply Flow Rate*Water QualitySupply Voltage Range5 - 40°C41 - 104°F0.1 bar g1.45 psi g1 L/minDeionised. ASTM II, >1MΩ,


Product Information SheetHydrogen Generatorsfor GC and GC/MS carrier gas applicationsThe Parker domnick hunter H-MD ultra highpurity hydrogen gas generators offer the optimumcombination of safe operation, reliability,performance and low cost of ownership.Utilising field proven PEM cell technology,hydrogen is produced on demand from deionisedwater and electricity, at low pressure and withminimal stored volume. Innovative control softwareallows unrivalled operational safety and reliability.The H-MD generators ideally supply GC andGC/MS carrier gas, in addition to all knowncombustion detectors that are routinely used intoday’s laboratory workflows. Four models operateat flow rates; 160 ml/min, 250 ml/min, 500 ml/minand 1100 ml/min.Hydrogen generators are available with RemoteNetworking software. RemoteNet allows up to27 hydrogen generators to be actively controlledfrom one central PC, and facilitates true cascadingcapabilities.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Eliminate dangerous hydrogen cylinders fromthe work place• Simple to install and operate• Compact, reliable with minimal maintenance• Produces a continuous supply of 99.99995%pure hydrogen up to 1,100ml/min and 6.9 bar• 2 year standard cell warranty• Optional automatic water fill and remotenetworking capabilityENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RatePurity*Water Consumption(24/7, full flow)Delivery Pressureml/min % L/week bar g psi gOptional AutoWater Fill (AWF)20H-MD 160 >99.99995 1.69 0.69-6.89 10-100 YES40H-MD 250 >99.99995 2.41 0.69-6.89 10-100 YES60H-MD 500 >99.99995 4.82 0.69-6.89 10-100 YES110H-MD 1100 >99.99995 10.60 0.69-6.89 10-100 Standard*With respect to oxygenNote: For auto water fill option add suffix AWF ie 20H-MD-AWFTechnical DataAmbient Temperature RangeWater Supply Pressure*Water Supply Flow Rate*Water QualitySupply Voltage Range5 - 40°C41 - 104°F0.1 bar g1.45 psi g1 L/minDeionised. ASTM II, >1MΩ,


ENGINEERING YOUR SUCCESS.The Analysis of 16 EPA PAHs by GC/MS usingHydrogen Carrier Gas.Mark Wilkinson (mark.wilkinson@parker.com), James Heseltine (james.heseltine@parker.com)Parker Hannifin LtdAIMThe aim of this technical paper is to optimizeand produce a robust and repeatable method forthe analysis of 16 EPA PAHs by GC/MS usinggenerated hydrogen carrier gas, over helium. Thisyields vastly improved analytical performance withshortened run times, whilst eliminating laboratoryhazards associated with high pressure vesselusage, storage and handling.IntroductionHydrogen is the choice of carrier gas for many applications, due to fasteranalysis times (compared with nitrogen and helium) with no reduction inresolution. In fact resolution is normally improved. However hydrogen’suse as a GC/MS carrier gas has long been avoided. Reactions in the ionsource, lack of pumping ability, and high background noise have all beencited as reasons not to use hydrogen as a carrier gas. Modern technologyhas to some extent allayed these concerns, but still helium continuesto be used for many established methods. Generated hydrogen offersan analytically superior, cost effective and safe solution over and abovecylinder fed helium.One of the most common analytical studies performed in manyenvironmental laboratories is the analysis of Polynuclear AromaticHydrocarbons (PAHs). PAHs are a group of compounds consisting ofmore than one benzene ring, found in fossil fuels, tar and various oils, aswell as being formed by the incomplete combustion of carbon containingcompounds, such as wood, coal and diesel, to name but a few.The Environment Protection Agency (EPA) has designated 16 PAHsas primary pollutants. The detection and quantification of thesecompounds, especially in water and soils, is of paramount importance forhuman health and the environment, due to their toxic and carcinogenicnature.Parker domnick hunter manufacture a range of hydrogen generatorsproviding ultra high purity hydrogen gas without the safety concernsassociated with high pressure cylinders. These generators improveanalytical performance, shorten run times and maximise productivity.Analytical considerationsAnalysis of the 16 EPA PAHs is normally carried out using GC-FID orGC/MS, with varying detection limits depending upon the medium inquestion and the analytical technique employed. GC/MS is favourable asit can eliminate non-required peaks, leaving only analytical informationof interest, utilizing Single Ion Monitoring (SIM) mode. This is especiallyimportant in complex matrices, where peaks of similar composition maylead to false interpretation.In any modern analytical laboratory, sample throughput and productivityare of utmost importance, where time is money.Employing hydrogen as a carrier gas is very common in GC-FIDworkflows, yielding superior chromatography, as well as reduced runtimes. Whilst it’s use within GC/MS workflows is less common, with thecorrect conditions, it has the potential to deliver superior performancebenefits over and above helium, with the added incentive of enhancedsafety and cost savings.Typical GC/MS analyses use helium which, as well as having vagaries insupply, often at elevated cost, also necessitates the use of cumbersome,heavy, high pressure cylinders (up to 200 bar g) which must be changedon a <strong>regula</strong>r basis.A Parker domnick hunter hydrogen generator produces ultra high puritycarrier gas at a constant pressure and flow rate, with minimal storedvolume, eliminating laboratory hazards associated with high pressurestorage vessels, such as cylinders.ExperimentalNaphthaleneAnalysis was performed on a Shimdazu QP2010s using SIM mode andsplitless injection (www.shimadzu.com)Hydrogen was supplied from a Parker domnick hunter 110H-MD generator(www.domnickhunter.com)Column supplied by Phenomenex - Zebron ZB5MS 0.25mm X 0.25µm(www.phenomemex.com)Injector - 300°CInterface - 320°CIon Source - 250°CFlow rate - 3ml/min (H2)Injection volume - 1µlOven Programme:-40°C (hold 1minute)100 °C @ 15 °C/min (hold 10 minutes)225 °C @ 5 °C /min (hold 0 minutes)320 °C @ 15 °C /minute (hold 2 minutes)Total run time = 48.33 minutesSampling time - 1minuteControl mode - Linear velocity


ResultsDetection limits of 1ppb were easily achieved, with excellent baselineresolution. 10 replicates were ran at this level, with typical RSD’s of


Product Information SheetHydrogen Generatorsfor ICP-MS instrumentsThe Parker domnick hunter 40H-ICP hydrogen gasgenerator, developed in collaboration with majorinstrument vendors, meets the initial purge and reactiongas requirements of the Collision Reaction Interface,providing simple routine removal of troublesomespectroscopic indifferences.Utilising field proven PEM cell technology, hydrogenis produced on demand from deionised water andelectricity, at low pressure and with minimal storedvolume. Innovative control software allows unrivalledoperational safety and reliability.The 40H-ICP hydrogen generator employs a fullyapproved low-pressure buffer arrangement, to caterfor elevated hydrogen flows required during the purgecycle of ICP-MS Instrumentation.Hydrogen generators are available with RemoteNetworking software. RemoteNet allows up to 27hydrogen generators to be actively controlled from onecentral PC, and facilitates true cascading capabilities.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Designed specifically for ICP-MS• Simple to install and operate• Compact, reliable with minimal maintenance• Eliminate dangerous hydrogen cylinders fromthe work place• 2 year standard cell warranty• Optional automatic water refill and remote networkingcapability’ENGINEERING YOUR SUCCESS.


Product Information SheetZero Air Generatorsfor GC combustion detector applicationsThe Parker domnick hunter UHP-ZA zero airgenerators produce a continuous stream of organicimpurity free air from an external dry compressedair source and offer superior limits of detectionover and above other modes of supply. Flow ratesrange from 1 L/min to 30 L/min.The UHP-ZA generators feature an interchangeabletop panel facilitating the direct mounting of anyParker domnick hunter hydrogen generator. Thestackable system forms an innovative, modular FIDgas station suitable for all known GC combustiondetectors such as FID, FPD and NPD.UHP-ZA generators may also be used inmany other chemical analysis and life scienceapplications, including LC/MS source gas,zero and combustion gas for total hydrocarbonanalysers and as a gas sensing calibration anddilution gas.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Ultra high purity, organic free, air for GC combustiondetectors• Increase resolution and detection limits of analysis• Compact, reliable with minimal operator attentionand maintenance• Eliminate inconvenient and potentially dangerousair cylinders• Payback period typically less than 24 months• Models available to supply up to 75 FID’sENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RateOrganic ImpurityAir Inlet @ 4 -10 bar g(58-145 psi g)Delivery PressureL/min ppm L/min bar g psi gIntegralCompressorUHP-10ZA-S 1


Product Information SheetZero Nitrogen Generatorsfor GC makeup gas and carrier gas applicationsThe Parker domnick hunter G5 zero nitrogengenerators employ robust, field proven technologyto produce ultra high purity nitrogen for GCmakeup and carrier gas applications. An integralheated platinum catalyst ensures carrier gradenitrogen free from organic impurities.The G5 generators provide a continuous streamof ultra high purity nitrogen from a single ‘plug &play’ unit. Models are available with and withoutan integral oil free compressor, are extremely quietin operation and are fully approved for use bymajor instrumentation manufacturers.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Ultra high purity, organic free, nitrogen• Ideal for GC make-up and carrier gas applicationsincluding ECD• Integral oil free compressor, with noise reductiontechnology• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RatePurity*Inlet Air @ 7 bar g(101.5 psi g)Delivery PressureL/min ppm organic impurity % L/min bar g psi gIntegralCompressorG5000 1 99.999 12 5 72.5 NOG5010 1 99.999 n/a 5 72.5 YES*Purity with respect to oxygenNote: Add suffix ‘E’ for 207-253V 50/60Hz ie G5000-EAdd suffix ‘W’ for 103 -126V 60Hz ie G5000-WTechnical DataAmbient Temperature RangeInlet Air Quality †Supply Voltage RangePort Connections Inlet †Outlet5 - 45°C41 - 113°FClean dry compressed airISO8573-1:2001 Class 2.-.1103 - 126V 60Hz207 - 253V 50/60Hz1 /4” Compression Fitting1 /8” Compression Fitting† Non compressor models onlyWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weight (with compressor) Weight (without compressor)mm in mm in mm in kg lb kg lbG5 range 842 33.1 345 13.6 413 16.3 55 121.3 51 112.4Preventative MaintenancePreventative Maintenance Kit Part Number Change FrequencyFilter Kit - G5 option 0 (no compressor) 606272355 12 monthsFilter Kit - G5 option 1 (compressor) 606272356 12 monthsCompressor Kit 230V - G5 option 1 606272336 12 monthsCompressor Kit 120V - G5 option 1 606272337 12 months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004742_02_EN 03/11ENGINEERING YOUR SUCCESS.


Product Information SheetHigh PurityNitrogen Generatorsfor GC and other critical analytical applicationsThe Parker domnick hunter G1 and G2 nitrogengas generators employ robust, field proventechnology to produce ultra high purity nitrogenfor critical life science, chemical analysis andspectroscopy applications. Flow rates range from0.55 L/min to 3 L/min, with purities >99.999%.The G1 and G2 generators provide a continuousstream of ultra high purity nitrogen from a single‘plug & play’ unit. Models are available with andwithout an integral an oil free compressor, areextremely quiet in operation and are fully approvedfor use by major instrumentation manufacturers.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Complete ‘Plug and Play’ system specifically designedfor critical analytical applications• Produces a continuous supply of 99.999% puritynitrogen 24 hours a day• Integral oil free compressor, with noise reductiontechnology• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RatePurity*Inlet Air @ 7 bar g(101.5 psi g)Oulet PressureL/min % L/min bar g psi gIntegral CompressorG1000 0.55 >99.999 7 5 72.5 NOG1010 0.55 >99.999 n/a 5 72.5 YESG1100 0.75 >99.999 9 5 72.5 NOG1110 0.75 >99.999 n/a 5 72.5 YESG2000 1.5 >99.999 18 5 72.5 NOG2010 1.5 >99.999 n/a 5 72.5 YESG2100 3.0 >99.999 36 5 72.5 NOG2110 3.0 >99.999 n/a 5 72.5 YES*Purity with respect to oxygenNote: Add suffix ‘E’ for 207-253V 50/60Hz ie. G1000-EAdd suffix ‘W’ for 103 -126V 60Hz ie. G1000-WTechnical DataAmbient Temperature RangeInlet Air Quality †Supply Voltage RangePort Connections Inlet †Outlet (G1 range)Outlet (G2 range)5 - 45°C41 - 113°FClean dry compressed airISO8573-1:2001 Class 2.-.1103 - 126V 60Hz207 - 253V 50/60Hz1 /4” Compression Fitting1 /8” Compression Fitting1 /4” Compression Fitting† Non compressor models onlyWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weight (with compressor) Weight (without compressor)mm in mm in mm in kg lb kg lbG1 range 842 33.1 345 13.6 413 16.3 57 125.7 53 116.8G2 range 874 34.4 345 13.6 663 26.1 90 198.4 77 169.7Preventative MaintenancePreventative Maintenance Kit G1 Part Number Change FrequencyFilter Kit - G1 option 0 (no compressor) 606272350 12 MonthsFilter Kit - G1 option 1 (compressor) 606272351 12 MonthsCompressor Kit 230V - G1 option 1 606272336 24 MonthsCompressor Kit 120V - G1 option 1 606272337 24 MonthsPreventative Maintenance Kit G2 Part Number Change FrequencyFilter Kit - G2 option 0 (no compressor) 606272350 12 MonthsFilter Kit - G2 option 1 (compressor) 606272352 12 MonthsCompressor Kit 230V - G2 option 1 606272334 12 MonthsCompressor Kit 120V - G2 option 1 606272335 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004740_02_EN 03/11ENGINEERING YOUR SUCCESS.


Product Information SheetHigh Purity Nitrogenand Dry Air GeneratorsAnalytical instrumentationThe Parker domnick hunter G6 and G7 nitrogenand dry air generators employ robust, field proventechnology to produce ultra high purity nitrogenand dry air suitable for chemical analysisapplications.The G6 and G7 generators provide a continuousstream of nitrogen and dry air from a single‘plug & play’ unit, are extremely quiet in operationand are fully approved for use by majorinstrumentation manufacturers.Innovative technology, design and functioncombine to completely eliminate all other modesof supply, facilitating maximum instrument uptime,attractive return on investment and provenanalytical performance.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Ideal for analytical instruments that require highpurity nitrogen and air• Produces a continuous supply of high purity nitrogen99.999% and dry air• Integral oil free compressor, with noise reductiontechnology• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Improve analysis and reproducibility with guaranteedhigh purity gasENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RatePurity*Delivery PressureNitrogen Dry Air Nitrogen Dry AirL/min L/min % °C (dew point) bar g psi gIntegralCompressorG6010 0.60 1.5 >99.999 -40 5 72.5 YESG7010 3 3 >99.999 -40 5 72.5 YES*Purity with respect to oxygenNote: Add suffix ‘E’ for 207-253V 50/60Hz ie G6010-EAdd suffix ‘W’ for 103 -126V 60Hz ie G6010-WTechnical DataAmbient Temperature RangeSupply Voltage Range5 - 45°C41 - 113°F103 - 126V 60Hz207 - 253V 50/60HzPort ConnectionsOutlet (G6010)Outlet (G7010)1 /8” Compression Fitting1 /4” Compression FittingWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weightmm in mm in mm in kg lbG6010 842 33.1 345 13.6 413 16.3 58 127.9G7010 874 34.4 345 13.6 663 26.1 93 205Preventative MaintenancePreventative Maintenance Kit G6 Part Number Change FrequencyFilter Kit - G6 option 1 (compressor) 606272351 12 MonthsCompressor Kit 230V - G6 option 1 606272336 12 MonthsCompressor Kit 120V - G6 option 1 606272337 12 MonthsPreventative Maintenance Kit G7 606272337 12 MonthsFilter Kit - G7 option 1 (compressor) 606272352 12 MonthsCompressor Kit 230V - G7 option 1 606272334 12 MonthsCompressor Kit 120V - G7 option 1 606272335 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004743_01_EN 03/11ENGINEERING YOUR SUCCESS.


Gas Generatorsfor LC/MS


Product Information SheetNitrogen Generatorsfor LC/MS applications - with optional economy modeThe Parker domnick hunter LCMS nitrogen gasgenerators employ robust, field proven technologyto meet the drying, sheath and nebulisationgas requirements of today’s latest LC/MSinstrumentation. Five models operate at flow ratesfrom 15 L/min to 50 L/min.The LCMS generators provide a continuous streamof high purity nitrogen from a single ‘plug & play’unit. Models are available with and without anintegral oil free compressor, are extremely quiet inoperation and are fully approved for use by majorinstrumentation manufacturers.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Ultra high purity, organic free, nitrogen• Produces a continuous supply of LC/MS gradenitrogen 24 hours a day• Integral oil free compressor, with noise reductiontechnology• Optional ECOMax economy module to increasecompressor life• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RatePurity*Air Inlet @ 8.5 bar g(123.3 psi g)Delivery PressureL/min % L/min bar g psi gIntegral CompressorLCMS15-0 15 >99 70 7 101.5 NOLCMS15-1 15 >99 n/a 7 101.5 YESLCMS20-0 20 >99 70 7 101.5 NOLCMS20-1 20 >99 n/a 7 101.5 YESLCMS30-0 30 >99 130 7 101.5 NOLCMS30-1 30 >99 n/a 7 101.5 YESLCMS40-0 40 >99 130 7 101.5 NOLCMS50-0 50 >98 130 7 101.5 NO*Purity with respect to oxygen Note: Add suffix ‘E’ for 207-253V 50/60Hz ie LCMS15-0-E Add suffix ‘W’ for 103 -126V 60Hz ie LCMS15-0-WTechnical DataAmbient Temperature Range 5 - 40°C 41 - 104°FInlet Air Quality † Clean dry compressed air ISO8573-1:2001 Class 2.-.1Supply Voltage Range103 - 126V 60Hz207 - 253V 50/60HzPort Connections Nitrogen Outlet / Air Inlet † 1 /4” Compression Fitting† Non compressor models onlyLCMS-ECOMax Add-on-Module (Optional Extra)Product Description Compatibility InstallationHeight (H) Width (W Depth (D) Weightmm in mm in mm in Kg lbLCMS-ECOMax-230VEnables economy mode cycle supplyingnitrogen gas only when required, whilstmaintaining constant purityLCMS15-50 modelswith and withoutintegral compressorAll required fittingssupplied withECOMax module103 4.06 303 11.93 408 16.06 7.8 17.2Weights and DimensionsHeight (H) Width (W) Depth (D) Weight (with compressor)Modelmm in mm in mm in kg lbLCMS 15-1 705 27.8 510 20.1 826 32.5 129 284LCMS 20-1 705 27.8 510 20.1 826 32.5 129 284LCMS 30-1 705 27.8 510 20.1 826 32.5 129 284Height (H) Width (W) Depth (D) Weight (without compressor)Modelmm in mm in mm in kg lbLCMS 15-0 705 27.8 510 20.1 559 22.0 89 196LCMS 20-0 705 27.8 510 20.1 559 22.0 89 196LCMS 30-0 705 27.8 510 20.1 760 22.9 135 298LCMS 40-0 705 27.8 510 20.1 760 22.9 135 298LCMS 50-0 705 27.8 510 20.1 760 22.9 135 298Preventative MaintenancePreventative Maintenance Kit Part Number Change FrequencyFilter Kit - all models 606272251 12 MonthsCompressor Kit 230V - Option 1 models 606272253 12 MonthsCompressor Kit 120V - Option 1 models 606272261 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004746_02_EN 03/11ENGINEERING YOUR SUCCESS.


Product Information SheetNitrogen Generatorsfor Agilent 6400 & 6500 LC/MS instrumentsThe Parker domnick hunter LCMS64/65 dualflow nitrogen gas generators employ robust, fieldproven technology to meet the drying, sheath,nebulisation and collision gas requirementsof the Agilent Technologies QQQ & Q-TOFinstrumentation portfolio.The LCMS64/65 generators provide twocontinuous streams of high purity nitrogen from asingle ‘plug & play’ unit. Models are available bothwith and without an integral oil free compressor,are extremely quiet in operation, and fully approvedfor use by major instrumentation manufacturers.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Complete ‘Plug and Play’ system specifically designedfor the Agilent 6400 & 6500• Produces a continuous supply of LC/MS grade nitrogen24 hours a day• Integral oil free compressor, with noise reductiontechnology• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionModelDrying, sheath& NebulisationNitrogenFlow RateCollision cellNitrogenDrying, sheath& NebulisationNitrogenPurity*Collision cellNitrogenAir Inlet @8.5 bar g(123.3 psi g)Delivery PressureL/min ml/min % % L/min bar g psi gIntegralCompressorLCMS64-0 18 200 >98 >99.999 90 6.8 98.6 NOLCMS64-1 18 200 >98 >99.999 n/a 6.8 98.6 YESLCMS65-0 30 200 >98 >99.999 90 6.8 98.6 NOLCMS65-1 30 200 >98 >99.999 n/a 6.8 98.6 YES*Purity with respect to oxygenNote: Add suffix ‘E’ for 207-253V 50/60Hz ie LCMS64-0-EAdd suffix ‘W’ for 103 -126V 60Hz ie LCMS64-0-WTechnical DataAmbient Temperature RangeInlet Air Quality †Supply Voltage Range5 - 40°C41 - 104°FClean dry compressed airISO8573-1:2001 Class 2.-.1103 - 126V 60Hz207 - 253V 50/60HzPort ConnectionsNitrogen OutletAir Inlet †1 /4” Compression Fitting1 /4” Compression Fitting† Non compressor models onlyWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weightmm in mm in mm in kg lbLCMS64-0 705 27.8 510 20.1 559 22 103 227LCMS64-1 705 27.8 510 20.1 826 32.5 143 315LCMS65-0 705 27.8 510 20.1 559 22 103 227LCMS65-1 705 27.8 510 20.1 826 32.5 143 315Preventative MaintenancePreventative Maintenance Kit Part Number Change FrequencyFilter Kit 606272251 12 MonthsCompressor Kit 230V - Option 1 models 606272253 12 MonthsCompressor Kit 120V - Option 1 models 606272261 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004748_02_EN 03/11ENGINEERING YOUR SUCCESS.


Product Information SheetNitrogen andDry Air Generatorsfor LC/MS instrumentsThe Parker domnick hunter LCMS20/3 dual flownitrogen and dry air generators employ robust,field proven technology to meet the nebulisationrequirements of LC/MS instruments, bothin positive and negative ionisation mode.The LCMS20/3 generators provide two continuousstreams of high purity nitrogen and dry air from asingle ‘plug & play’ unit. Models are available withand without an integral oil free compressor, areextremely quiet in operation and are fully approvedfor use by major instrumentation manufacturers.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Complete ‘Plug and Play’ system specificallydesigned for LC/MS• Produces a continuous supply of LC/MS gradenitrogen 24 hours a day• Integral oil free compressor, with noise reductiontechnology• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionModelNebulisationNitrogen (positiveionisation mode)Flow RateNebulisationDry Air (negativeionisation mode)NebulisationNitrogen (positiveionisation mode)Purity*NebulisationDry Air (negativeionisation mode)Air Inlet @8.5 bar g(123.3 psi g)Delivery PressureL/min L/min % °C (dew point) L/min bar g psi gIntegralCompressorLCMS20/3-0 20 3 >99 -40 85 7 101.5 NOLCMS20/3-1 20 3 >99 -40 n/a 7 101.5 YES*Purity with respect to oxygenNote: Add suffix ‘E’ for 207-253V 50/60Hz ie. LCMS20/3-0-EAdd suffix ‘W’ for 103 -126V 60Hz ie. LCMS20/3-0-WTechnical DataAmbient Temperature RangeInlet Air Quality †Supply Voltage RangePort Connections† Non compressor models onlyOutletInlet †5 - 40°C41 - 104°FClean dry compressed airISO8573-1:2001 Class 2.-.1103 - 126V 60Hz207 - 253V 50/60Hz1 /4” Compression Fitting1 /4” Compression FittingWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weightmm in mm in mm in kg lbLCMS20/3-0 705 27.8 510 20.1 559 22 103 227LCMS20/3-1 705 27.8 510 20.1 826 32.5 143 315Preventative MaintenancePreventative Maintenance Kit Part Number Change FrequencyFilter Kit 606272251 12 MonthsCompressor Kit 230V - Option 1 models 606272253 12 MonthsCompressor Kit 120V - Option 1 models 606272261 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004747_03_EN 07/11ENGINEERING YOUR SUCCESS.


Product Information SheetMIDIGAS LABfor multiple LC/MS and centralised laboratorysupply applicationsThe Parker domnick hunter MIDIGAS LABnitrogen gas generators employ robust, fieldproven technology to produce high puritynitrogen for a number of medium flow, highdemand analytical applications, such asmultiple LC/MS installations. Flow rates rangefrom 9 L/min to 408 L/min, with purities from>95% to >99.999%.The MIDIGAS LAB generators provide acontinuous stream of high purity nitrogen froma innovative modular unit. Models are availablewith or without an external compressed airsystem, and offer a compelling alternative toother modes of supply such as cylinders orliquid.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analyticalperformance.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Innovative modular system specifically for multipleLC/MS and centralised supply applications• Produces a continuous stream of high purityanalytical grade nitrogen 24 hours a day• Integral automatic economy mode and continuouspurity monitoring• Digital and analogue outputs of remote monitoringand alarm capabilities• Eliminate inconvenient and potentially dangerousnitrogen cylinders and dewars• Robust, reliable with minimal operator attentionand maintenanceENGINEERING YOUR SUCCESS.


Product SelectionPerformance data is based on 7 bar g (100 psi g) air inlet pressure and 20° - 25°C (66° - 77°F) ambient temperature. Consult Parker for performance under other specific conditions.Nitrogen flow rate m 3 /hr vs Purity (Oxygen Content)Model Unit 10ppm 100ppm 250ppm 500ppm 0.1% 0.5% 1.0% 2.0% 3.0% 4.0% 5.0%MIDIGAS2 LABm 3 /hr 0.55 1.2 1.5 1.9 2.4 3.4 4.3 5.8 7.2 8.4 9.4cfm 0.3 0.7 0.9 1.1 1.4 2.0 2.5 3.5 4.2 4.9 5.5MIDIGAS4 LABm 3 /hr 1.2 2.4 3.2 3.9 4.7 6.9 8.5 11.6 14.3 16.7 18.8cfm 0.7 1.4 1.9 2.3 2.8 4.1 5.0 6.8 8.4 9.8 11.1MIDIGAS6 LABm 3 /hr 1.5 3.2 4.2 5.3 6.5 9.5 11.5 15.2 18.7 21.7 24.5cfm 0.9 1.9 2.5 3.1 3.8 5.6 6.8 8.9 11.0 12.8 14.4m 3 reference standard = 20°C, 1013 millibar(a), 0% relative water vapour pressure.Technical DataAmbient temperature range 5 - 50°CNitrogen outlet pressureup to 11 bar gAir inlet pressure6 to 13 bar gAir Inlet Quality Pressure Dewpoint -40°CParticulateOil


Product Information SheetMAXIGAS LABFor multiple LC/MS and centralised laboratorysupply applicationsThe Parker domnick hunter MAXIGAS LABnitrogen gas generators employ robust, fieldproven technology to produce high puritynitrogen for a number of high flow, high demandanalytical applications including multiple LC/MS.Flow rates range from 30 L/min to 2500 L/min,with purities from >95% to >99.999%.The MAXIGAS LAB generators provide acontinuous stream of high purity nitrogen froma innovative modular unit. Models are availablewith or without an external compressed airsystem, and offer a compelling alternative toother modes of supply such as cylinders orliquid.Innovative design and technology facilitatemaximum instrument uptime, attractive return oninvestment and proven analytical performance.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Innovative modular system specifically formultiple LC/MS and centralised laboratory supplyapplications• Produces a continuous stream of high purity anlyticalgrade nitrogen 24 hours a day• Integral automatic economy mode and continuouspurity monitoring• Digital and analogue outputs of remote monitoringand alarm capabilities• Eliminate inconvenient and potentially dangerousnitrogen cylinders and dewars• Robust, reliable with minimal operator attentionand maintenanceENGINEERING YOUR SUCCESS.


Product SelectionPerformance data is based on 7 bar g (100 psi g) air inlet pressure and 20° - 25°C (66° - 77°F) ambient temperature. Consult Parker for performance under other specific conditions.Nitrogen flow rate m 3 /hr vs Purity (Oxygen Content)Model Unit 10ppm 50ppm 100ppm 250ppm 500ppm 0.1% 0.5% 1.0% 2.0% 3.0% 4.0% 5.0%MAXIGAS104 LABMAXIGAS106 LABMAXIGAS108 LABMAXIGAS110 LABMAXIGAS112 LABMAXIGAS116 LABMAXIGAS120 LABm 3 /hr 2 3.8 5.5 7.1 8.6 9 14.1 17.8 22 25.8 29 32.2cfm 1.2 2.2 3.2 4.2 5 5.3 8.3 10.5 12.9 15.2 17.1 19.0m 3 /hr 3 5.7 8.3 10.7 13 13.4 21.2 26.6 32.8 38.7 43.5 48.3cfm 1.8 3.3 4.9 6.3 7.6 7.9 12.5 15.7 19.3 22.8 25.6 28.4m 3 /hr 4 7.6 11 14.3 17.3 18 28.3 35.5 43.8 51.6 58 64.4cfm 2.3 4.5 6.4 8.4 10.2 10.6 16.7 20.9 25.8 30.4 34.1 37.9m 3 /hr 5 9.5 13.8 17.8 21.6 22.4 35.3 44.4 54.7 64.5 72.5 80.4cfm 2.9 5.6 8.1 10.5 12.7 13.2 20.8 26.1 32.2 38.0 42.7 47.3m 3 /hr 6 11.3 16.5 21.4 25.9 26.8 42.4 53.3 65.7 77.4 87.1 96.5cfm 3.5 6.7 9.7 12.6 15.2 15.8 25 31.4 38.7 45.6 51.3 56.8m 3 /hr 7.9 14.4 20.9 27.1 32.8 34 53.7 67.5 83.2 98.1 110.3 122.3cfm 4.6 8.5 12.3 15.9 19.3 20.0 31.6 39.7 49 57.7 64.9 72.0m 3 /hr 9.8 17.4 25.3 32.8 39.7 41.2 65 81.7 100.7 118.7 133.5 148cfm 5.8 10.2 14.9 19.3 23.4 24.2 38.3 48.1 59.3 69.9 78.6 87.1m 3 reference standard = 20°C, 1013 millibar(a), 0% relative water vapour pressure.Technical DataAmbient temperature range 5 - 50°CNitrogen outlet pressureAir inlet pressureup to 13 bar g6 to 15 bar gAir Inlet QualityPressure DewpointParticulateOil-40°C


Gas Generators forSpectroscopy, TOC,Circular Dichroism,Digital Radiographyand evaporation


Product Information SheetNitrogen GeneratorsAnalytical and General Laboratory ApplicationsThe Parker domnick hunter G3 and G4 nitrogengas generators employ robust, field proventechnology to produce ultra high purity nitrogen forlife science, chemical analysis and spectroscopyapplications. Flow rates range from 4 L/min to14 L/min, with purities from >98% to >99.99%.The G3 and G4 generators provide a continuousstream of ultra high purity nitrogen from a single‘plug & play’ unit. Models are available withand without an integral oil free compressor, areextremely quiet in operation and are fully approvedfor use by major instrumentation manufacturers.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Complete ‘Plug and Play’ system for laboratoryapplications• Produces a continuous supply of nitrogen from98 to 99.99% purity• Integral oil free compressor, with noise reductiontechnology• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Improve analysis and reproducibility with guaranteedhigh purity gasENGINEERING YOUR SUCCESS.


Product Information SheetNitrogen Generatorsfor Circular Dichroism and ICP purge applicationsThe Parker domnick hunter CD10 nitrogen gasgenerator employs robust, field proven technologyto meet the complete purge gas requirementsof today’s latest Circular Dichroism and ICPinstrumentation.The CD10 generator provides a continuous streamof ultra high purity nitrogen suitable for optic,source and plasma torch purge applications,maximising instrument uptime, productivity andenhancing spectroscopic resolution. The CD10 isextremely quiet in operation and fully approved foruse by major instrumentation manufacturers.Innovative design and technology facilitatemaximum instrument uptime, attractive returnon investment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Specifically designed for Circular Dichroismand ICP applications• Produces a continuous supply of high purity 99.9965%nitrogen 24 hours a day• Simple to install and operate• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionModelFlow RatePurity*Air Inlet @ 8.5 bar g(123.3 psi g)Delivery PressureL/min % L/min bar g psi gIntegral CompressorCD10-0 10 >99.9965 130 7 101.5 NO*Purity with respect to oxygenNote: Add suffix ‘E’ for 207-253V 50/60Hz ie CD10-0-EAdd suffix ‘W’ for 103 -126V 60Hz ieCD10-0-WTechnical DataAmbient Temperature RangeInlet Air QualitySupply Voltage Range5 - 40°C41 - 104°FClean dry compressed airISO8573-1:2001 Class 2.-.1103 - 126V 60Hz207 - 253V 50/60HzPort ConnectionsOutletInlet1 /4” Compression Fitting1 /4” Compression FittingWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weightmm in mm in mm in kg lbCD10-0 705 27.8 510 20.1 760 29.9 135 298Preventative MaintenancePreventative Maintenance Kit Part Number Change FrequencyFilter Kit 606272251 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004745_01_EN 03/11ENGINEERING YOUR SUCCESS.


Product Information SheetNitrogen Generatorsfor Edge Medical DevicesThe Parker domnick hunter G1-LN-800 nitrogengas generator employs robust, field proventechnology to produce ultra high purity nitrogenfor critical life science applications.The G1-LN-800 generator provides a continuousstream of ultra high purity nitrogen from a single‘plug & play’ unit. This system is available with anintegral oil free compressor, and is extremely quietin operation.Innovative design and technology facilitatemaximum instrument uptime, attractive return oninvestment and proven analytical performance,eliminating the need for other modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Complete ‘Plug and Play’ system specificallydesigned for Edge Medical• Produces a continuous supply of high purity 99.999%nitrogen 24 hours a day• Integral oil free compressor, with noise reductiontechnology• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionModelFlow Rate Purity* Outlet Pressureml/min % mbar g psi gIntegral CompressorG1-LN-800 800 >99.999 17 0.25 YES*Purity with respect to oxygenNote: Add suffix ‘E’ for 207-253V 50/60Hz ie G1-LN-800-EAdd suffix ‘W’ for 103 -126V 60Hz ie G1-LN-800-WTechnical DataAmbient Temperature RangeSupply Voltage Range5 - 45°C41 - 113°F103 - 126V 60Hz207 - 253V 50/60HzPort Connections Outlet 1 /4” Compression FittingWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weightmm in mm in mm in kg lbG1-LN-800 567 22.3 400 15.7 700 27.5 82 181Preventative MaintenancePreventative Maintenance Kit Part Number Change FrequencyFilter and Compressor Kit 230V 606272440 12 MonthsFilter and Compressor Service Kit 120V 606272442 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004754_01_EN 03/11ENGINEERING YOUR SUCCESS.


Product Information SheetDry Air Generatorsfor spectroscopy applicationsThe Parker domnick hunter G8 and G9 dry air generatorsemploy robust, field proven technology to produce highpurity dry air suitable for spectroscopy applications.The G8 and G9 generators provide a continuous streamof dry air from a single ‘plug & play’ unit, are extremelyquiet in operation and are fully approved for use by majorinstrumentation manufacturers.Innovative design and technology facilitate maximuminstrument uptime, attractive return on investment andproven analytical performance, eliminating the need forother modes of supply.Contact Information:Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296Email: gasgen@parker.comwww.parker.com/dhfnsProduct Features:• Ideal for analytical instruments that require ultra dry air• Eliminate inconvenient and potentially dangerousnitrogen cylinders• Integral oil free compressor, with noise reductiontechnology• Produces a continuous supply of clean dry air 24 hoursa day• Compact, reliable with minimal operator attentionand maintenance• Phthalate-free componentryENGINEERING YOUR SUCCESS.


Product SelectionFlow Rate Purity Delivery PressureL/min °C (dew point) bar g psi gIntegralCompressorG8010 3 -40 5 72.5 YESG9010 6 -40 5 72.5 YESNote: Add suffix ‘E’ for 207-253V 50/60Hz ie G8010-EAdd suffix ‘W’ for 103 -126V 60Hz ie G8010-WTechnical DataAmbient Temperature RangeSupply Voltage Range5 - 45°C41 - 113°F103 - 126V 60Hz207 - 253V 50/60HzPort Connections Outlet 1 /8” Compression FittingWeights and DimensionsModelHeight (H) Width (W) Depth (D) Weightmm in mm in mm in kg lbG8010 842 33.1 345 13.6 413 16.3 54 119G9010 842 33.1 345 13.6 413 16.3 54 119Preventative MaintenancePreventative Maintenance Kit G8 Part Number Change FrequencyFilter Kit - G8 option 1 (compressor) 606272351 12 MonthsCompressor Kit 230V - G8 option 1 606272336 12 MonthsCompressor Kit 120V - G8 option 1 606272337 12 MonthsPreventative Maintenance Kit G9 Part Number Change FrequencyFilter Kit - G9 option 1 (compressor) 606272351 12 MonthsCompressor Kit 230V - G9 option 1 606272336 12 MonthsCompressor Kit 120V - G9 option 1 606272337 12 Months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004744_02_EN 03/11ENGINEERING YOUR SUCCESS.


Product Information SheetC02 Free Air Generatorsfor FT-IR & TOC ApplicationsThe Parker Zander K-MT-LAB CO 2 removalpurifier employs, robust, field proven technologyto produce ultra high purity CO 2 free air for criticalFT-IR and TOC purge applications. Flow ratesrange from 1.5 L/min to 100 L/min, with purities


Technical DataCleanroom air generatorK-MT-LABK-MTLAB 1 K-MTLAB 3 K-MTLAB 6Outlet fl ow rate 1.5 Nl/min 20 Nl/min 100 Nl/minRegeneration gas volume 10 Nl/min 36 Nl/min 75 Nl/minInlet flow rate 11.5 Nl/min 56 Nl/min 175 Nl/minInlet temperature + 5°C to + 30°CCO 2 outlet concentrationResidual hydrocarbonsParticle separation< 1 ppm at max. 380 ppm at the inlet< 0.003 ppm0.01 μmPressure dewpoint up to - 70°COperating pressureInitial differential pressure incl. filtration5 barü300 mbarConnections G 1/4” G 1/4” G 3/8”Weights and DimensionsModelHeight (H) Width (W) Depth (D) Weightmm in mm in mm in kg lbK-MTLAB1 401 15.8 372 14.6 210 8.2 14 30.8K-MTLAB3 827 32.5 429 16.8 210 8.2 20 44K-MTLAB6 1185 46.6 580 22.8 300 11.8 54 119Preventative MaintenancePreventative Maintenance Kit Part Number Change FrequencyFilter cartridges, condensate drain, silencer, reset moduleFilter cartridges, condensate drain, silencer, main valves, seal set, reset moduleDesiccant pack, 2.0 kg of molecular filter granulate *KM 18 LAB 1-3KM 18 LAB 6KM 36 LAB 1-3KM 36 LAB 6DESPAC 2 LAB18 months36 months©2011 Parker Hannifin Corporation. All rights reserved.Catalogue: 174004758_00_EN 03/11ENGINEERING YOUR SUCCESS.


Applications by MarketApplication found in this marketX Application in this market is a major target areaApplicationsPharmaceuticalBiotechnologyChemicalOil & GasGovernmentalAcademiaFood & BeverageEnvironmentalProducts for Gas ChromatographyGC - Flame Ionisation Detector (FID) X X X XGC - Flame Photometric Detector (FPD)GC - Nitrogen Phosphorous Detector (NPD)GC - Electron Capture Detector (ECD)GC - Thermal Conductivity Detector (TCD)GC - Automatic Thermal Desorption (ATD)GC - Atomic Emission Detector (AED)GC - Electrolytic Conductivity Detector (ELCD & Hall ELCD)GC/MS - Carrier GasSemiconductorProducts for LC/MS InstrumentsLC/MS - Nebulization Gas (Nitrogen) X X X XLC/MS - Source GasLC/MS - Exhaust GasLC/MS - Sheath GasLC/MS - Collision Cell Gas/Drift GasLC/MS - Matrix Assisted Laser Desorption IonisationLC/MS - Multiple Instrument SupplyFT/MS - Fourier Transform Mass SpectrometryProducts for SpectroscopyFourier-Transform Infra Red Spectrometer, FT-IR X X X XNuclear Magnetic Resonance, NMRInductively Coupled Plasma - Mass Spectrometry (ICP-MS)Induct Optical Emission Spectrometers (ICP-OES)Atomic Adsorption (AA - Flame)Particle SizingXProducts for AnalysersTotal Organic Carbon Analyser (TOC) X X XTotal Hydrocarbon Analyser (THA)Differential Scanning Calorimetry (DSC)Thermal Gravimetric Analyser (TGA)C02 AnalyserChemisorption/PhysisorptionOther Laboratory ApplicationsSample Preparation/Solvent Evaporators X X X XCircular Dichroism (CD)Evaporative Light Scattering Detector (ELSD) X X XCorona Charged Aerosol Detector (CAD)Condensation Nucleation Light Scattering Detector (CNLSD)C02 Incubators (IVF, Stem Cell & Regenerative Medicine)Chemical Vapour Deposition Instrumentation (CVD)Plasma Cleaning Instrumentation (UCP)Digital Radiography (Edge, General Electric, Varian Medical)Hydrogenation (Organic Chemistry)


Applications GuideKeyUHP = Ultra High Purity, >99.99 - >99.9999% with respect to oxygenZero Grade = Free from residual hydrocarbonsHP = High Purity, >98 >99.9% with respect to oxygenCDA = Clean Dry AirInstrument Gas Requirement Purity Flow rate Generator TechnologyProduct for Gas Chromatography (GC)GC -Flame Ionisation Detector (FID)H2 as fuel gas UHP 30-50 ml/min Hydrogen 'H' or 'H-MD'H2 as carrier gas(displacing Helium)PEM + Desiccant or PEM + MicrodryerUHP up to 200 ml/min Hydrogen, 'H-MD' PEM + Micro DryerZero Air as flame support gas Zero Grade 300-500 ml/min Zero Air UHP-ZA-S Catalytic ModuleN2 for packed carrier gas Zero Grade 20-50 ml/min Zero Nitrogen, G5 N2 PSA + Catalytic ModuleN2 as detector make-up gas Zero Grade 30-50 ml/min Zero Nitrogen, G5 N2 PSA + Catalytic ModuleGC -Flame Photometric Detector (FPD)GC -Nitrogen Phosphorous Detector (NPD)GC -Electron Capture Detector (ECD)GC -Thermal Conductivity Detector (TCD)GC -Automatic Thermal Desorption (ATD)GC -Atomic Emission Detector (AED)GC - Electrolytic Conductivity Detector(ELCD & Hall ELCD)Hydrogen as fuel gas UHP 60-90 ml/min Hydrogen 'H' or 'H-MD'PEM + Desiccant or PEM + MicrodryerZero Air as flame support gas Zero Grade 90-120 ml/min Zero Air UHP-ZA-S Catalytic ModuleHydrogen as carrier gas(displacing Helium)UHP up to 50 ml/min Hydrogen, 'H-MD' PEM + Micro DryerNitrogen as detector make-up gas Zero Grade up to 30 ml/min Zero Nitrogen, G5 N2 PSA + Catalytic ModuleNitrogen as carrier gas Zero Grade up to 60 ml/min Zero Nitrogen, G5 N2 PSA + Catalytic ModuleNitrogen as detector make-up gas Zero Grade up to 100 ml/min Zero Nitrogen, G5 N2 PSA + Catalytic ModuleHydrogen as carrier gas UHP up to 50 ml/min Hydrogen ‘H’ or ‘H-MD’Nitrogen as purge gas UHP up to 150 ml/min UHP Nitrogen, G1 or G2 N2 PSAPEM + Desiccant or PEM + MicrodryerNitrogen as carrier gas Zero Grade up to 1 ml/min Zero Nitrogen, G5 N2 PSA + Catalytic ModuleHydrogen as reaction gas UHP 70 to 200 ml/min Hydrogen ‘H’ or ‘H-MD’PEM + Desiccant or PEM + MicrodryerGC/MS - Carrier Gas Hydrogen as carrier gas (displacing Helium) UHP up to 50 ml/min Hydrogen, ‘H-MD’ PEM + Micro DryerProducts for LC/MS InstrumentsLC/MS -Nebulisation GasNitrogen used to nebulise liquid into aerosolHPup to 32 L/min Nitrogen, LCMS-15 to 50 N2 PSA34 - 228 L/min Nitrogen, Midi Gas Lab N2 PSAup to 567 L/min Nitrogen, Maxi Gas Lab N2 PSALC/MS -Source GasLC/MS -Exhaust GasLC/MS -Sheath GasLC/MS -Collision Cell GasLC/MS -Matrix Assisted Laser Desorption IonisationLC/MS -Multiple Instrument SupplyFT/MS -Fourier Transform Mass SpectrometryNitrogen used as a source gas HP up to 17 L/min TriGas, LCMS-5000 series N2 MembraneZero Air as source gas to removehydrocarbonsZero Grade up to 17 L/min TriGas, LCMS-5000 series Catalytic ModuleZero Grade up to 17 L/min Zero Air HP-ZA Catalytic ModuleNitrogen for exhaust gas purge HP up to 8 L/min TriGas, LCMS-5000 series N2 MembraneClean Dry Air for exhaust gas purge CDA up to 8 L/min TriGas, LCMS-5000 series CDA MembraneNitrogen used as inerting/blanket gasHPup to 32 L/min Nitrogen, LCMS-15 to 50 N2 PSA34 - 228 L/min Nitrogen, Midi Gas Lab N2 PSAup to 567 L/min Nitrogen, Maxi Gas Lab N2 PSANitrogen used as collision gas UHP up to 25 ml/min Nitrogen, G5 N2 PSANitrogen as laser purge guide UHP up to 5 L/min Nitrogen, G4 N2 PSANitrogen as nebulisation/sheath/exhaustgasHPVariousNitrogen as laser flush/purge gas HP up to 100 L/minNitrogen, Midi Gas LabMaxi Gas LabNitrogen, Midi Gas LabMaxi Gas LabN2 PSAN2 PSAN2 PSAN2 PSA


Instrument Gas Requirement Purity Flow rate Generator TechnologyProducts for SpectroscopyFourier-Transform Infra Red Spectrometer (FT-IR)Nuclear Magnetic Resonance (NMR)Inductively Coupled Plasma - Mass Spectrometry(ICP-MS)Inductively Coupled PlasmaOptical Emission Spectrometers (ICP-OES)C02 free air for sample compartment,optics air bearing and microscope purge gasAir for lifting, spinning & ejecting, 400MHzC02 freeairCDAHPup to 28 L/min C02 free air generators PSA - Desiccant60-100 L/minCDA, MidaMidi Gas LabMaxi Gas LabCDA PSA - DesiccantN2 PSAN2 PSAHydrogen as collision cell reaction gas UHP up to 250 ml/min Hydrogen, ‘H-MD’ PEM + Micro DryerNitrogen as purge gas for plasma torch UHP up to 9 L/min Nitrogen, G4 N2 PSAAtomic Emission Spectrometers (AA - Flame) Air for flame support gas CDA 28-200 L/min CDA, Midas PSA - DesiccantParticle Sizing Instruments Air to purge and drying gas CDA up to 100 L/min CDA, Midas PSA - DesiccantProducts for AnalysersTotal Organic Carbon Analyser (TOC)C02 free & Zero Grade air for carrier gasC02 freeair100-500 ml/minC02 Free AirPSA - DesiccantZero Grade Zero Air, UHP-ZA-S Catalytic ModuleNitrogen for carrier gas UHP 50-700 ml/min Nitrogen, G2 N2 PSATotal Hydrocarbon Analyser (THA)Hydrogen as fuel gas UHP 5-50 ml/min Hydrogen 'H' or 'H-MD'PEM + Desiccant or PEM + MicrodryerZero Air as flame support gas Zero Grade 50-500 ml/min Zero Air, UHP-ZA-S Catalytic ModuleDifferential Scanning Calorimetry (DSC) Nitrogen as shield/sheath gas UHP 100 ml/min Nitrogen, G1 N2 PSAThermal Gravimetric Analyser (TGA) Nitrogen as inerting/blanket furnace gas UHP 300 ml/min Nitrogen, G1 N2 PSAC02 AnalyserC02 free air as calibration gasC02 freeair550-1000 ml/min C02 free air PSA - DesiccantChemisorption/PhysisorptionHydrogen as measurement gas UHP up to 250 ml/min Hydrogen, 'H-MD' PEM + Micro DryerNitrogen as measurement gas UHP up to 250 ml/min Nitrogen, G1 N2 PSAOther Laboratory ApplicationsSample Preparation/Solvent Evaporators(TurboVap)Nitrogen as inert evaporation gas HP 6-50 L/min Nitrogen, G4 or LCMS-50 N2 PSACircular Dichroism (CD) Nitrogen as source and optics purge UHP up to 10 L/min Nitrogen, CD-10 N2 PSAEvaporative Light Scattering Detector (ELSD) Nitrogen as nebulisation gas HP up to 8 L/min Nitrogen, G4 N2 PSACorona Charged Aerosol Detector (CAD) Nitrogen as nebulisation gas HP up to 8 L/min Nitrogen, G4 N2 PSACondensation Nucleation Light Scattering Detector(CNLSD)C02 Incubators (IVF, Stem Cell & RegenerativeMedicine)Chemical Vapour Deposition Instrumentation (CVD)Nitrogen as nebulisation gas HP up to 8 L/min Nitrogen, G4 N2 PSANitrogen to create oxygen deficientatmosphereHP up to 12 L/min Nitrogen, G4 N2 PSAHydrogen to aid deposition process UHP up to 1L/min Hydrogen, 'H-MD' PEM + Micro DryerNitrogen to aid deposition process UHP up to 1L/min Nitrogen, G1 & G2 N2 PSAPlasma Cleaning Instrumentation (UCP) Hydrogen as a high efficiency process gas UHP up to 1000 ml/min Hydrogen, ‘H-MD’ PEM + Micro DryerDigital Radiography(Edge, General Electric, Varian Medical)Nitrogen to inert/purge diode array UHP up to 550 ml/min Nitrogen, G1 N2 PSAHydrogenation (Organic Chemistry) Hydrogen as reaction gas UHP up to 250 ml/min Hydrogen, ‘H’ range PEM + Desiccant


Notes


Parker WorldwideEurope, Middle East, AfricaAE – United Arab Emirates,DubaiTel: +971 4 8127100parker.me@parker.comAT – Austria, Wiener NeustadtTel: +43 (0)2622 23501-0parker.austria@parker.comAT – Eastern Europe, WienerNeustadtTel: +43 (0)2622 23501 900parker.easteurope@parker.comAZ – Azerbaijan, BakuTel: +994 50 2233 458parker.azerbaijan@parker.comBE/LU – Belgium, NivellesTel: +32 (0)67 280 900parker.belgium@parker.comBY – Belarus, MinskTel: +375 17 209 9399parker.belarus@parker.comCH – Switzerland, EtoyTel: +41 (0)21 821 87 00parker.switzerland@parker.comCZ – Czech Republic, KlecanyTel: +420 284 083 111parker.czechrepublic@parker.comDE – Germany, KaarstTel: +49 (0)2131 4016 0parker.germany@parker.comDK – Denmark, BallerupTel: +45 43 56 04 00parker.denmark@parker.comES – Spain, MadridTel: +34 902 330 001parker.spain@parker.comFI – Finland, VantaaTel: +358 (0)20 753 2500parker.finland@parker.comFR – France, Contamine s/ArveTel: +33 (0)4 50 25 80 25parker.france@parker.comGR – Greece, AthensTel: +30 210 933 6450parker.greece@parker.comHU – Hungary, BudapestTel: +36 1 220 4155parker.hungary@parker.comIE – Ireland, DublinTel: +353 (0)1 466 6370parker.ireland@parker.comIT – Italy, Corsico (MI)Tel: +39 02 45 19 21parker.italy@parker.comKZ – Kazakhstan, AlmatyTel: +7 7272 505 800parker.easteurope@parker.comNL – The Netherlands, OldenzaalTel: +31 (0)541 585 000parker.nl@parker.comNO – Norway, AskerTel: +47 66 75 34 00parker.norway@parker.comPL – Poland, WarsawTel: +48 (0)22 573 24 00parker.poland@parker.comPT – Portugal, Leca da PalmeiraTel: +351 22 999 7360parker.portugal@parker.comRO – Romania, BucharestTel: +40 21 252 1382parker.romania@parker.comRU – Russia, MoscowTel: +7 495 645-2156parker.russia@parker.comSE – Sweden, SpångaTel: +46 (0)8 59 79 50 00parker.sweden@parker.comSK – Slovakia, Banská BystricaTel: +421 484 162 252parker.slovakia@parker.comSL – Slovenia, Novo MestoTel: +386 7 337 6650parker.slovenia@parker.comTR – Turkey, IstanbulTel: +90 216 4997081parker.turkey@parker.comUA – Ukraine, KievTel +380 44 494 2731parker.ukraine@parker.comUK – United Kingdom, WarwickTel: +44 (0)1926 317 878parker.uk@parker.comZA – South Africa, Kempton ParkTel: +27 (0)11 961 0700parker.southafrica@parker.comNorth AmericaCA – Canada, Milton, OntarioTel: +1 905 693 3000US – USA, ClevelandTel: +1 216 896 3000Asia PacificAU – Australia, Castle HillTel: +61 (0)2-9634 7777CN – China, ShanghaiTel: +86 21 2899 5000HK – Hong KongTel: +852 2428 8008IN – India, MumbaiTel: +91 22 6513 7081-85JP – Japan, TokyoTel: +81 (0)3 6408 3901KR – South Korea, SeoulTel: +82 2 559 0400MY – Malaysia, Shah AlamTel: +60 3 7849 0800NZ – New Zealand, Mt WellingtonTel: +64 9 574 1744SG – SingaporeTel: +65 6887 6300TH – Thailand, BangkokTel: +662 186 7000-99TW – Taiwan, TaipeiTel: +886 2 2298 8987South AmericaAR – Argentina, Buenos AiresTel: +54 3327 44 4129BR – Brazil, Sao Jose dos CamposTel: +55 800 727 5374CL – Chile, SantiagoTel: +56 2 623 1216MX – Mexico, ApodacaTel: +52 81 8156 6000European Product Information CentreFree phone: 00 800 27 27 5374(from AT, BE, CH, CZ, DE, DK, EE, ES, FI,FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU,SE, SK, UK, ZA)©2011 Parker Hannifin Corporation. All rights reserved. Catalogue: 174004739_02_EN 09/11 Parker Hannifin Manufacturing Limiteddomnick hunter Filtration and Separation DivisionDukesway, Team Valley Trading EstateGateshead, Tyne and WearEngland NE11 0PZTel: +44 (0)191 402 9000Fax: +44 (0)191 482 6296www.parker.com/dhfns