13.07.2015 Views

SSM/SSV Series Alarm Bells

SSM/SSV Series Alarm Bells

SSM/SSV Series Alarm Bells

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

S P R I N K L E R S Y S T E M S M O N I T O R I N G<strong>SSM</strong>/<strong>SSV</strong> <strong>Series</strong><strong>Alarm</strong> <strong>Bells</strong>Models AvailableUL/FM Models<strong>SSM</strong>24-6<strong>SSM</strong>24-8<strong>SSM</strong>24-10<strong>SSV</strong>120-6<strong>SSV</strong>120-8<strong>SSV</strong>120-10<strong>SSV</strong>120-6ULC/Canadian Models<strong>SSM</strong>24-6A<strong>SSM</strong>24-8A<strong>SSM</strong>24-10A<strong>SSV</strong>120-6A<strong>SSV</strong>120-8A<strong>SSV</strong>120-10AWeatherproof Back BoxWBBProduct OverviewApproved for indoor and outdoor useLow current drawHigh dB outputThree sizes available 6″, 8″, 10″AC and DC modelsDC models are polarized for use withsupervision circuitryMount directly to standard 4″ squareelectrical boxSystem Sensor’s <strong>SSM</strong> and <strong>SSV</strong> series bells are low current, high decibel notificationappliances for use in fire and burglary systems or other signaling applications.Reliable Performance. The <strong>SSM</strong> and <strong>SSV</strong> series provide loud resonant tones.The <strong>SSM</strong> series operate on 24VDC and are motor driven, while the <strong>SSV</strong>series operate on 120VAC utilizing a vibrating mechanism.Simplified Installation. For indoor use, the <strong>SSM</strong> and <strong>SSV</strong> series mount to astandard 4 inch square electrical box. For outdoor applications, weatherproofback box, model number WBB, is used.The <strong>SSM</strong> and <strong>SSV</strong> series come pre-wired, to reduce installation time. The <strong>SSM</strong>series incorporate a polarized electrical design for use with supervision circuitry.Engineering SpecificationsModel shall be a <strong>SSM</strong> or <strong>SSV</strong> <strong>Series</strong> alarm bell. <strong>Bells</strong> shall have underdomestrikers and operating mechanisms. Gongs on said bells shall be no smallerthan nominal 6″/8″/10″ (specify size) with an operating voltage of 24VDC or120VAC (specify by part number). <strong>Bells</strong> shall be suitable for surface or semiflushmounting. Outdoor surface mounted installations shall be weatherproof(using optional WBB weatherproof electrical box). Otherwise bellsshall mount to a standard 4″ square electrical box having a maximum projectionof 2 1 ⁄2″. <strong>Bells</strong> shall be located as shown on the drawings or as determinedby the Authority Having Jurisdiction. <strong>Bells</strong> shall be listed forindoor/outdoor use by Underwriters Laboratories and the California StateFire Marshal, and approved by Factory Mutual and MEA.


Standard SpecificationsOperating Temperature Range–31°F to 140°FOperating Voltage<strong>SSM</strong> series 24VDC<strong>SSV</strong> series 120VACTerminationProvided with 2 sets of leads forin/out wiring.Service UseFire <strong>Alarm</strong>General SignalingBurglar <strong>Alarm</strong>Warranty3 yearsGong Diameter Operating Maximum CurrentModel (inches) Nominal Voltage Voltage Range (at Rated Voltage) Sound Output (dB)<strong>SSM</strong>24-6 6 85<strong>SSM</strong>24-8 8 24VDC 19.2 to 26.4VDC 0.024A 85<strong>SSM</strong>24-10 10 86<strong>SSV</strong>120-6 6 83<strong>SSV</strong>120-8 8 120VAC 96 to 132VAC 0.032A + 10% 78<strong>SSV</strong>120-10 10 85* Sound output measured at Underwriter Laboratories, as specified in UL464Ordering InformationUL/FM Model Numbers ULC/Canadian Models Description<strong>SSM</strong>24-6 <strong>SSM</strong>24-6A Bell, 6″, 24VDC, Polarized, 85dba<strong>SSM</strong>24-8 <strong>SSM</strong>24-8A Bell, 8″, 24VDC, Polarized, 85dba<strong>SSM</strong>24-10 <strong>SSM</strong>24-10A Bell, 10″, 24VDC, Polarized, 86dba<strong>SSV</strong>120-6 <strong>SSV</strong>120-6A Bell, 6″, 120VAC, 83dba<strong>SSV</strong>120-8 <strong>SSV</strong>120-8A Bell, 8″, 120VAC, 78dba<strong>SSV</strong>120-10 <strong>SSV</strong>120-10A Bell, 10″, 120VAC, 85dbaWBBWeatherproof Back Box for <strong>SSM</strong> and <strong>SSV</strong> series, when installed outdoorsSystem Sensor Sales and ServiceSystem Sensor Headquarters3825 Ohio AvenueSt. Charles, IL 60174Ph: 800/SENSOR2Fx: 630/377-6495Documents-on-Demand800/736-7672 x3www.systemsensor.comSystem Sensor CanadaPh: 905.812.0767Fx: 905.812.0771System Sensor EuropePh: 44.1403.276500Fx: 44.1403.276501System Sensor in ChinaPh: 86.29.524.6253Fx: 86.29.524.6259System Sensor in SingaporePh: 65.6273.2230Fx: 65.6273.2610System Sensor – Far EastPh: 85.22.191.9003Fx: 85.22.736.6580System Sensor – AustraliaPh: 613.54.281.142Fx: 613.54.281.172System Sensor – IndiaPh: 91.124.637.1770 x.2700Fx: 91.124.637.3118© 2003 System Sensor. The company reserves the right to change product specifications without notice. A05-0260-005•01/03•#1038

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!