The <strong>Evacuator</strong> Series presents manyadvantages over current offerings.HIGH EFFICIENCY PORTABLE UTILITY PUMPSRule your dewatering! Backed by the Rulebrand of DC pumps, a brand enjoying over 45years of operational excellence, the <strong>Evacuator</strong>series is a new line of high efficiency portableutility pumps.Providing a robust 2000 GPH, a capable 4000 GPH, ora sizeable 8000 GPH, the <strong>Evacuator</strong> series provides aperfect collaboration between size and functionality.The series offers smaller and lighter form factors thancomparable pumps. The innovative power connection,which allows for direct operation from your vehicle’s 12volt battery via two heavy duty battery clips, providesflexibility for use in work environments requiring fast,efficient removal of water.Perfect for dewatering and drainage applications:• Construction sites dewatering• Foundation trenches dewatering• General “off grid” dewatering situations• Basement drainage• Pool drainage• Bunker drainage on golf courses• Emergency boat drainage• Sewer system flood water removal<strong>Evacuator</strong> Series Features and Benefits• Harsh environment DC motor technology, proven in over 15 million operational units• Direct operation from a 12 volt vehicle battery, providing flexibility in location and use• Extended dry run time capability, preventing pump damage due to inconsistent water flow• Thermal overload, ensuring motor protection in the event of a locked rotor• Integrated on/off switch in supplied cabling, providing operational convenience


<strong>Evacuator</strong> Series HIGH EFFICIENCY PORTABLE UTILITY PUMPS<strong>Spec</strong>ifications EV2000 EV4000 EV8000Voltage 12 Vdc 12 Vdc 12 VdcFlow 2000 GPH (7570 LPH) 4000 GPH (113250 LPH) 8000 GPH (30283 LPH)Flow with includedhose adaptor1700 GPH (6435 LPH) N/A N/AAmp. Draw 12 amps (approx.) 20 amps (approx.) 30 amps (approx.)Protection Thermal Cut Off (TCO) Thermal Cut Off (TCO) Thermal Cut Off (TCO) foreach motorPort Configuration1.125 inch outlet (35 mm)(includes adaptor for 3/4”garden hose thread)2 inch outlet (51 mm) 3 inch outlet (76 mm)Height 8” (203 mm) 10.5” (267 mm) 8.5” (215 mm)Width 6” (152 mm) 5.5” (140 mm) 12” (305 mm)Length 6.5” (165 mm) 7” (178 mm) 13.5” (343 mm)Pump Weight 3 lbs (1.4 kg) 5.5 lbs (2.5 kg) 11 lbs (5 kg)Cable Weight 3 lbs (1.4 kg) 3 lbs (1.4 kg) 4.5 lbs (2 kg)Packaged Weight 7 lbs (3.2 kg) 9.5 lbs (4.3 kg) 18 lbs (8.2 kg)Packaged Dimensions15.5”L x 12.5”W x 10.5”H(394mm x 317mm x 267mm)15.5”L x 12.5”W x 10.5”H(394mm x 317mm x 267mm)Master Pack Qty. 1 1 1Exploded View15.5”L x 12”W x 13.5”H(394mm x 305mm x 343mm)Model No. EV20000 42237 11214 9Model No. EV40001 42237 11212 2Model No. EV80000 42237 11164 7Ev8000––– 1Ev4000––– 527 (8.23)24 (7.32)21 (6.4)––– 2––– 3Ev2000––– 5––– 4PressureOf Water ft (m)18 (5.49)15 (4.57)12 (3.66)9 (2.74)8000 GPH (30283 LHP)<strong>Evacuator</strong> SEriESPortablE utility PumPS4000 GPH (13250) LPHUSAXylemCape Ann Industrial ParkGloucester, MA 01930Tel: +1.978.281.0440Fax: +1.978.283.2619Warranty: All products of the company are sold and all services of the company are offered subject to the company’s warranty and terms and conditionsof sale, copies of which will be furnished upon request. The information provided herein is for guidance only, it does not constitute a guaranteeof the performance or specification of any individual product or component.www.xylemflowcontrol.comUKXylemBingley Road, HoddesdonHertfordshire EN11 OBUTel: +44 (0) 1992 450145Fax: +44 (0) 1992 4671326 (1.83)––– 4Installation, Operation,Maintenance––– 6www.rule-industies.com3 (.91)Installation, fonctionnement,UNITED STATESFrentretienEast Coast0Tel: +1 978 281 0440 Fax: +1 978 283 26192000 GPH (7570 LPH)Einbau, Betrieb,West Coast0 1000 2000 3000 4000DE––– 7, 8, 9Tel: +1 714 557 4700 Fax: +1 714 628 8478Wartung 5000 6000 7000 8000(3,785) (7,570) (11,356) (15,141) (18,927) (22,712) (26,497) (30,283)UNITED KINGDOMInstallazione, funzionamento,Tel: +44 (0) 1992 450 145 Fax: +44 (0) 1992 467 132Flow GPH itService Parts(LPH) manutenzioneGERMANYThe following Key is a list of replacement 1 parts available for 2 3 4 5 6 Tel: +49 (0) 40 53 53 73 0 Fax: +49 (0) 40 53 53 73 11Installatie, gebruik,Nl7 8this product – if the part required is listed as part of anonderhoud9assembly, it may only be purchased in the assembly.Description EV8000 Handle Motor Module DischargeITALYEV8000/4000 EV4000/2000 EV2000EV8000 Wire EV4000 Wire EV2000 WireTel: +39 039 6852323 Fax: +39 039 666307Installation, drift,& Strainer Clip [1]Housing Strainer [1] HandleStrainer SE Harness underhåll Harness HarnessKey Description Replacement PartJAPANPart No. R-3001Tel: +81 (0) 45 475 8906 Fax: +81 (0) 45 477 1162NumberR-3002 R-3003 R-3004 R-3007 R-3008 R-3005 Instalación, funcionamiento R-3006 yR-3001ES mantenimientoR-30091 Handle and StrainerClip2 Motor Module [1] R-30023 Discharge Housing R-30034 EV8000/4000 Strainer[1]R-30045 EV4000/2000 Handle R-30076 EV2000 Strainer R-30087 EV8000 Wire Harness R-30058 EV4000 Wire Harness R-30069 EV2000 Wire Harness R-3009review all SaFEty information in FroNt of this Databooklet prior to replacing parts or servicing the<strong>Evacuator</strong> 8000 utility PumpCHINATel: (86)21 2208 2888 Fax: (86)21 2208 2999GERMANYXylemOststrasse 2822844 NorderstedtTel: +49.40.53.53.73.0Fax: +49.40.53.53.73.11THE PRODUCT DESCRIBED HEREIN IS SUBJECT TO THE RULE ONE YEAR LIMITEDWARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST.JAPANNHK Jabsco Company Ltd.3-21-10, Shin-YokohamaKohoku-Ku, Yokohama, 222-0033Tel: +81.045.475.8906Fax: +81.045.477.1162ITALYXylemVia Tommaseo, 620059 Vimercate, MilanoTel: +39.039.685.2323Fax: +39.039.666.307© 2011 Xylem Inc. All rights reserved. Printed in the U.S.A. No. 950-0802© Copyright 2011 ITT Corporation 950-0746 Rev A. 4/11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!