<strong>Scania</strong> Bodywork Control Message 2<br />
Identifierare: 0C FF F9 XX<br />
Sändningsintervall: 100 ms<br />
Detaljerad beskrivning av CAN-meddelanden<br />
Byte Bit Length Explanation State Resolution Limits Note<br />
1 1 8 Message configuration version 02h 0 to 250 A<br />
2 1 2 Increased idle speed switch 1 (ISSW1) B<br />
ISSW1 not demanded 00<br />
ISSW1 demanded <strong>01</strong><br />
Error indicator 10<br />
Not available or not installed <strong>11</strong><br />
3 2 Increased idle speed switch 2 (ISSW2) C<br />
ISSW2 not demanded 00<br />
ISSW2 demanded <strong>01</strong><br />
Error indicator 10<br />
Not available or not installed <strong>11</strong><br />
5..8 Not defined<br />
3 1 2 Second vehicle speed limiter<br />
Speed limit not requested 00<br />
Speed limit requested <strong>01</strong><br />
Error indicator 10<br />
Not available or not installed <strong>11</strong><br />
3..4 Not defined<br />
5 2 Torque limit 1<br />
Torque limit 1 not requested 00<br />
Torque limit 1 requested <strong>01</strong><br />
Error indicator 10<br />
Not available or not installed <strong>11</strong><br />
7 2 Torque limit 2<br />
Torque limit 2 not requested 00<br />
Torque limit 2 requested <strong>01</strong><br />
Error indicator 10<br />
Not available or not installed <strong>11</strong><br />
4 1 2 Engine start<br />
Engine start not requested 00<br />
Engine start requested <strong>01</strong><br />
Error indicator 10<br />
Not available or not installed <strong>11</strong><br />
3..4 Not defined<br />
5 2 Monitored engine stop<br />
Monitored engine stop not requested 00<br />
<strong>11</strong>:<strong>90</strong>-<strong>01</strong> © <strong>Scania</strong> CV AB 2008, Sweden 14