CIMON-<strong>XPanel</strong> HMIHMI-CM-XT-04CDHMI-CM-XT-07CDHMI-CM-XT-08CDHMI-CM-XT-10CDDIMENSIONSHMI-CM-XT-12CDHMI-CM-XT-15CD<strong>L011051</strong>*All units are in mm910 East Orangefair Ln. <strong>Anaheim</strong>, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com


CIMON-<strong>XPanel</strong> HMIHMI-CM-XT-04CDHMI-CM-XT-07CDPANEL CUTOUT DIMENSIONSHMI-CM-XT-08CDHMI-CM-XT-10CDHMI-CM-XT-12CDHMI-CM-XT-15CD<strong>L011051</strong>*All units are in mm910 East Orangefair Ln. <strong>Anaheim</strong>, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com


CIMON-<strong>XPanel</strong> HMIRS-232CConnector Pin # Name Description1 DCD Data Carrier Detect2 RD Receive Data3 TD Transmit Data4 DTR Data Terminal Ready5 SG Signal Ground6 DSR Data Set Ready7 RTS Request To Send8 CTS Clear To Send9 RI Ring IndicatorThis interface is used to connect the Xpanel to the host (PLC) via an RS-232C cable. Whenyou use COM1 RS-232C port, you must not use COM1 RS-422/485HOOK UP DIAGRAMSRS-422/485Connector Pin # Name Description1 RDB Receive Data B2 RDA Receive Data A3 GND Ground4 SDB Send Data B5 SDA Send Data AThis interface is used to connect the Xpanel to the host (PLC) via an RS-422/485 cable. Whenyou use COM1 RS-422/485 port, you must not use COM1 RS-232CIf you connect the Xpanel to the host via an RS-485 cable (2wire), you must connect SDA andSDB lines. The RS-485 of the <strong>XPanel</strong> runs uner auto toggle mode To reduce the risk ofdamaging the RS-422 circuit.<strong>L011051</strong>910 East Orangefair Ln. <strong>Anaheim</strong>, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com


CIMON-<strong>XPanel</strong> HMIRJ45RJ45 Front ViewRJ45 Side ViewDirect Cable: Host HubHOOK UP DIAGRAMSHost Cable Pin # Color Color Pin # Hub Cable1 Orange/W Orange/W 12 Orange Orange 23 Green/W Green/W 34 Blue Blue 45 Blue/W Blue/W 56 Green Green 67 Brown/W Brown/W 78 Brown Brown 8Direct Cable: Host HostHost Cable Pin # Color Color Pin # Host Cable1 Orange/W Green/W 12 Orange Green 23 Green/W Orange/W 34 Blue Blue 45 Blue/W Blue/W 56 Green Orange 67 Brown/W Brown/W 78 Brown Brown 8<strong>L011051</strong>910 East Orangefair Ln. <strong>Anaheim</strong>, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com


CIMON-<strong>XPanel</strong> HMIWarnings• To avoid an electric shock, when connecting the Xpanel power cord to the power terminal block,confirm that the Xpanel power supply is completely turned OFF via a breaker or similar unit.• Since there is no power switch on the Xpanel unit, be sure to attach a breaker-type switch to its powercord.• To avoid a short caused by loose ring terminals, be sure to use ring terminals with an insulatingsleeve.• When the FG terminal is connected, be sure the wire is grounded. Not grounding the Xpanel unit willresult in excess noise and vibrationConnecting the Xpanel Power CordWhen connecting the power cord, be sure to follow the procedures given below:• Confirm that the power cord is unplugged from the power supply.• Unscrew the screws from the middle three terminals, align the ring terminals and re-attach the screws.• Confrim that the ring terminal wires are connected correctly.• The torqe required to tighten these screws is 0.5 to 0.6 NMWIRINGPower Supply CautionPay special attention to the following instructions when connecting the power cord terminals to the Xpanelunit:• If the power supply voltage exceeds the Xpanel’s specified range, connect a voltage transformer.• Betwen the line and the ground, be sure to use a low noise power supply. If there is still an excessiveamount of noise, connect a noise reducing transformer.• The power supply cord should not be bundled with or kept close to the main circuit lines orinput/output signal lines.• Connect a surge abosorber to handle power surges.• To reduce noise, make the power cord as short as possible.Grounding Caution• When grounding to the rear face field ground terminal, be sure to create an exlusive ground.• Inside the Xpanel unit, the signal ground and field ground terminals are connected to eachother.• When connecting to an external device to the Xpanel with the signal ground terminal, ensurethat no short-circuit loop is created when you set up the system.<strong>L011051</strong>910 East Orangefair Ln. <strong>Anaheim</strong>, CA 92801 Tel. (714) 992-6990 Fax. (714) 992-0471 www.anaheimautomation.com