13.07.2015 Views

REYQ168PAYD_Submittal Data Sheet_460V.pdf - HTS

REYQ168PAYD_Submittal Data Sheet_460V.pdf - HTS

REYQ168PAYD_Submittal Data Sheet_460V.pdf - HTS

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Submittal</strong> <strong>Data</strong> <strong>Sheet</strong>Project Name:Location:Engineer:Submitted to:Submitted by:Reference:Approval:Date:Construction:Unit #:Drawing #:PerformanceIndoor Unit Model No:Outdoor Unit Model No:Cooling Capacity (Btu/hr):Sensible Capacity (Btu/hr):Cooling Input Power (kW):Cooling EER (Btu/hr / kW):SEER:Heating Capacity (Btu/hr):Heating Input Power (kW):Heating COP (Btu/hr / Btu/hr):HSPF:Ducted<strong>REYQ168PAYD</strong>160000014.711.4N/A18000016.23.3N/AIndoor Unit Type:Condensing Unit Type:Cooling NominalConditionsHeating NominalConditionsNominal Piping LengthNominal Height DifferenceNominal Water Flow Rate14-Ton VRV-III Heat RecoveryIndoor: 80°FDB, 67°FWBOutdoor: 95°F DBWater Cooled: EWT: 85 °FIndoor: 70°F DBOutdoor: 47°F DB, 43°F WBWater Cooled: EWT: 70 °F25 ft0 ftIndoor Unit DetailsPower Supply (V/Hz/Ph:)Power Supply Connections:Min. Circuit Amps MCA (A):Max. Fusible Amps MFA (A):Dimensions (HxWxD):Panel (HxWxD):Net Weight (lbs):Weight with Panel (lbs):N/AN/AN/AAirflow Rate (CFM wet coil)Moisture Removal (pt/h):Gas Pipe Connection (inch):Liquid Pipe Connection (inch):Condensate Connection (inch):Sound Pressure Level (dBA):Sound Power Level (dBA):Nominal External Static Pressure (inH2O)Max Ext Static Pressure (inH2O)N/ACondensing Unit DetailsPower Supply (V/Hz/Ph):Power Supply Connections:Min. Circuit Amps MCA (A):Max. Fusible Amps MFA (A):Max. Starting Current MSC(A):Rated Load Amps RLA (A):Total Overcurrent Amps (A):Dimensions (HxWxD):Net Weight (lbs):Compressor Type:Capacity Control Range (%):Capacity Index Limit:460/60/3phL1, L2, L3 Ground20.3+16.725 + 25697.1+3.9+8.431.5 + 16.566-1/8x75-1/2x30-1/8573 + 463Inverter9 - 100100.8 - 218 (130%)Airflow Rate (CFM):Gas Pipe Connection (inch):Liquid Pipe Connection (inch):H/L Pressure Connection (inch):H/L Equalizing Connection (inch):Water Inlet Connection (inch FPT):Water Outlet Connection (inch FPT):Condensate Drain Outlet (inch FPS):Sound Pressure Level (dBA):Sound Power Level (dBA):Unit Heat Rejection (kW):Max. No. of Indoor Units:6,530+6,5301-1/85/87/83/46129System DetailsRefrigerant Type:Holding Refrigerant Charge (lbs):Additional Charge (oz/ft):Pre-charge Piping (Length ft):Max. Pipe Length (Horizontal ft):Max. Pipe Length (Vertical ft):R-410A19.8+18.1install data-540 ft164 ft (295 ft) / 295 ftCooling Operation Range (°F):Cooling Range w/Baffle (°F):Heating Operation Range (°F):Heating Range w/Baffle (°F):Cooling Inlet Water Temp (°F):Heating Inlet Water Temp (°F):Water Flow Range (GPM):(-4) 23 - 1100 - 77 / -4 - 60Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006Page 1 of 4Daikin AC TRL Generated <strong>Submittal</strong> <strong>Data</strong>www.daikinac.com(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)


<strong>Submittal</strong> <strong>Data</strong> <strong>Sheet</strong>Project Name:Location:Engineer:Submitted to:Submitted by:Reference:Approval:Date:Construction:Unit #:Drawing #:


<strong>Submittal</strong> <strong>Data</strong> <strong>Sheet</strong>Project Name:Location:Engineer:Submitted to:Submitted by:Reference:Approval:Date:Construction:Unit #:Drawing #:Dimensional Drawing - Condensing UnitDaikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006Page 3 of 4Daikin AC TRL Generated <strong>Submittal</strong> <strong>Data</strong>www.daikinac.com(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)


<strong>Submittal</strong> <strong>Data</strong> <strong>Sheet</strong>Project Name:Location:Engineer:Submitted to:Submitted by:Reference:Approval:Date:Construction:Unit #:Drawing #:NotesRequires Multi Connection Pipe Kit (BHFP26P90U),Std U.S. Warranty: 6yrs Compressor, 1yrs Parts, 1yr Limited LaborDaikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006Page 4 of 4Daikin AC TRL Generated <strong>Submittal</strong> <strong>Data</strong>www.daikinac.com(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!