<strong>IMRT</strong> <strong>QA</strong> <strong>Solutions</strong> Faster, easier, electronic <strong>IMRT</strong> <strong>QA</strong>


<strong>IMRT</strong> <strong>QA</strong>. Do it faster.Reduce the time spent on both machine<strong>QA</strong> and patient plan verification withVarian's <strong>IMRT</strong> <strong>QA</strong> <strong>Solutions</strong>. This set oftools streamlines the <strong>IMRT</strong> <strong>QA</strong> processand helps you establish and documentyour own best practices.


Make it easier.Varian’s expertise in <strong>IMRT</strong> now includes <strong>IMRT</strong><strong>QA</strong> <strong>Solutions</strong>. Through customizable processautomation and reduced dependence on film,these tools make <strong>IMRT</strong> <strong>QA</strong> faster and easier.Do it your way.Establish a <strong>QA</strong> program tailored toyour requirements. You choose thetests, the tolerances, and the frequency.Automate your processes.Automation with <strong>IMRT</strong> <strong>QA</strong> <strong>Solutions</strong>can cut your testing and verificationtime by as much as 80%. Createautomated testing protocols that guideyou through the day’s tasks. Reducemanual data entry and eliminatemanual calculation with automateddata recording.Easily organize, analyze, and presentyour results.Get a full, automated record of all <strong>QA</strong>data, organized the way you need it.Use trend analysis to identify potentialproblems before they cause downtime.Meet reporting requirements moreeasily with a wide variety of reports.Speed up and improve yourpre-treatment <strong>QA</strong>.Satisfy regulatory requirements andvalidate the quality of your <strong>IMRT</strong>treatment plans with faster data.Perform relative dosimetry testswithout film in significantly less time,and capture a denser array of datapoints compared with specializedmeasurement devices.3


<strong>IMRT</strong> <strong>QA</strong> <strong>Solutions</strong> Faster, easier, electronic <strong>IMRT</strong> <strong>QA</strong>Argus LINAC has over 40 tests. One of them, the DailyMonitor Test, makes morning warm-up more efficientwith easy data acquisition and immediate feedback.<strong>IMRT</strong> <strong>QA</strong> <strong>Solutions</strong> is a set of threeproducts: Argus LINAC, Argus <strong>IMRT</strong>,and Portal Dosimetry. Together, theyhelp you answer the three importantquestions in <strong>IMRT</strong> <strong>QA</strong>.Is the linear accelerator operating to specification?Identify trends in flatness andsymmetry with Argus LINAC. Trendgraphs can also be created for otherquantities, such as central axisoutput and energy data.Ensure consistent, smooth execution of linear acceleratortests with Argus LINAC. This module contains the fullset of linear accelerator tests used in current standards ofpractice. Customizable test templates, reminders, alerts,and a rules engine put you in control of data management.Status reports, electronic interfaces to testequipment, and auto-calculation of test results speed updata collection. An Operator mode guides therapistsquickly through daily testing routines, while a Physicsmode provides the physicist with complete oversightand analysis capabilities.4


All Varian MLCs generateDynaLog files during thecourse of each dynamicor segmental treatment.DynaLog files record theactual and expectedposition of each leaf inthe MLC, as well asthe cumulative dosefraction delivered every50 milliseconds. 1DynaLog Analysis provides a wide range of toolsfor in-depth analysis of collimator operation.View historical results and create trend graphs bothduring and after testing. Argus LINAC analyzes dataaccording to your parameters and displays it accordingto your needs.Argus LINAC’s extensive reporting capabilities help youcomply more efficiently with AAPM Task Group, NCRP,JCAHO, ACR, and IAEA recommendations and regulations.Data organized electronically with Argus LINACis easily harnessed for fast report generation. You specifythe date range and the data subset for each report, thenchoose from a virtually unlimited variety of formats.Is the MLC operating to specification?Argus <strong>IMRT</strong> also introduces a new technology,DynaLog Analysis. This tool analyzes the DynaLog filescreated for any dynamic or segmental field or plan. UseDynaLog Analysis to:• compare the actual and expected leaf motions usingtolerances you define• perform statistical analysis using histograms, RMScalculations, and trending to help detect weakeningmotors before they fail• see leaf motion simulations and in-depth graphicalanalysis of any individual leaf or gap.1 This description of the DynaLog file pertains to sliding windowand step-and-shoot fields. For conformal arc fields, the DynaLog filerecords the actual and expected position of each leaf along withthe gantry angle.Maintain optimum MLC performance with Argus<strong>IMRT</strong>’s broad range of MLC tests and sophisticatedDMLC analysis tools. The MLC tests help you validatecollimator operation, document safety checks, andorganize data into a comprehensive record. As withArgus LINAC, Argus <strong>IMRT</strong> lets you easily find andformat data for your reporting needs.5


Can I verify my treatment plans?With Varian’s Portal Dosimetry, quickly verify that the doseyou plan is the dose you deliver. These automated, electronictools help you compare, analyze, and document resultswithout having to expose, process, and calibrate film.Use Portal Dosimetry to compare an electronic relativedose image from Varian’s PortalVision portal imager to apredicted portal dose image calculated by Varian’sEclipse treatment planning system. Then get instant,quantitative comparisons of the two images, including dosedifference, gamma analysis, 2 point dose measurements,and line profiles.Another advantage of Portal Dosimetry for pre-treatment<strong>IMRT</strong> <strong>QA</strong> is a higher density of data points. Direct-todigitaldata capture provides significantly more dosemeasurement points than is possible with special-purposemeasurement devices. Higher density data makes it easierto evaluate <strong>IMRT</strong> fields with high dose gradients.The predicted image (upper right) appears quitesimilar to the acquired image (lower right). Thegamma analysis (left) reveals some mismatch(yellow and yellow-green areas signify a gammaindex >1), prompting closer scrutiny of the field.2 Gamma analysis is a method for comparing two-dimensional dosedistributions, incorporating both distance-to-agreement and dosedifference criteria. (See Low DA, et al.; A technique for thequantitative evaluation of dose distributions; Med Phys 1998 May;25(5):656-61.)Process Time of Varian’s Portal Dosimetryvs. Film-Based DosimetryData Density Acquisition of Varian’sPortal Dosimetry vs. Other Devices5MoreHours4321.510.5Density ofPractitionersSample Size Per FieldLessFilm-BasedDosimetryVarian’s PortalDosimetryOtherDevicesVarian’s PortalDosimetryFilm-based dosimetry takes 2 to 4 hours for amajority of users. Varian’s Portal Dosimetry takesabout 0.5 to 1.5 hours—a significant savings in time.6


Increase your confidence in your<strong>IMRT</strong> program. Call today fora demonstration of Varian’s<strong>IMRT</strong> <strong>QA</strong> <strong>Solutions</strong>.


Oncology Systems3100 Hansen WayPalo Alto, CA 94304-1038tel 650.424.5700tel 800.544.4636www.varian.comUSA HeadquartersCaliforniaVarian Medical SystemsPalo Alto, CATel: 650.424.5700800.544.4636Fax: 650.493.5637USA Regional OfficesCaliforniaVarian Medical SystemsCorona, CATel: 909.280.4401Fax: 909.280.4300GeorgiaVarian Medical SystemsMarietta, GATel: 770.955.1367Fax: 678.255.3850IllinoisVarian Medical SystemsDes Plaines, ILTel: 847.296.5533Fax: 847.296.0043New JerseyVarian Medical SystemsClark, NJTel: 732.340.9346Fax: 732.381.1060European HeadquartersSwitzerlandVarian Medical SystemsInternational AGZug, SwitzerlandTel: 41.41.749.8844Fax: 41.41.740.3340AustriaVarian Medical SystemsGesellschaft m.b.H.Voesendorf, AustriaTel: 43.1.698.56.56Fax: 43.1.698.56.59BelgiumVarian Medical SystemsBelgium N.V.Sint-Katelijne, BelgiumTel: 0800.903.23Fax: 31.30.636.2466FinlandVarian Medical SystemsFinland OyHelsinki, FinlandTel: 358.9.430.771Fax: 358.9.455.4585FranceVarian Medical Systems FranceParis, FranceTel: 33.1.53.60.82.00Fax: 33.1.44.24.07.59IndiaVarian Medical SystemsIndia Pvt Ltd.Mumbai, IndiaTel: 91.22.26162301/04Fax: 91.22.26162277ItalyVarian Medical SystemsItalia, S.p.A.Cernusco s/N (MI), ItalyTel: 39.02.921.351Fax: 39.02.921.35240NetherlandsVarian Medical SystemsNetherlands B.V.Houten, NetherlandsTel: 31.30.634.0506Fax: 31.30.636.2466ScandinaviaVarian Medical SystemsScandinavia ASHerlev, DenmarkTel: 45.44.500.100Fax: 45.44.500.190Spain/PortugalVarian Medical SystemsIbérica, S.L.Madrid, SpainTel: 34.91.799.4530Fax: 34.91.799.4541Asian HeadquartersHong KongVarian Medical SystemsPacific, Inc.Kowloon, Hong KongTel: 85.22.724.2836Fax: 85.22.369.4280ChinaVarian Medical SystemsChina Ltd.Beijing, P.R. ChinaTel: 8610.6512.7169Fax: 8610.6523.2039JapanVarian Medical Systems K.K.Chuo-ku, Tokyo, JapanTel: 81.3.3639.9700Fax: 81.3.3639.9623Latin American HeadquartersFloridaVarian Medical SystemsMiami, FL USATel: 305.929.1970Fax: 305.929.1971BrazilVarian Medical Systemsdo Brasil Ltda.São Paulo, BrazilTel: 55.11.3047.2655Fax: 55.11.3168.9748GermanyVarian Medical SystemsDeutschland GmbHDarmstadt, GermanyTel: 49.61.51.73130Fax: 49.61.51.731313UK/IrelandVarian Medical SystemsUK Ltd.Crawley, West Sussex, UKTel: 44.1293.531.244Fax: 44.1293.510.260Australian HeadquartersAustraliaVarian Medical Systems(Australasia) Pty Ltd.Frenchs ForestNSW 2086Sydney, AustraliaTel: 612.9975.8800Fax: 612.9452.5737Varian and Varian Medical Systems are registered trademarks of Varian Medical Systems, Inc. The names of other companies and products mentioned herein are usedfor identification purposes only and may be trademarks or registered trademarks of their respective owners.RAD 9004 © 2003 Varian Medical Systems, Inc. Printed in USA. 7/03 (20k)