21.07.2015 Views

GGT10 Brochure.pdf - Scintrex

GGT10 Brochure.pdf - Scintrex

GGT10 Brochure.pdf - Scintrex

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SPECIFICATIONS FOR THE GGT-10 TRANSMITTERGeneralDescription: Broadband, constant-current, time andfrequency domain, medium power geophysical transmitterEnclosure: Welded, hardened aluminum frame inserted ina high impact fiberglass caseSize: 53 x 51 x 37 cm (21 x 20 x 14.5 in)Weight: 51 kg (113 lb)Operating temperature: - 40°to +55°C ( - 40° to +130°F)Operating humidity: 0 to 90%, non-condensingElectrical CharacteristicsDrives a loop or grounded dipoleTurnoff time: Under 10 µsec for a resistive load; 125 µsecfor a 300 x 300 m loop (16 ohms resistance, full current)Maximum input: 10KVA @ 30°COutput voltage range: 50 to 1000 VOutput current range: 0.2 to 20A (Optional 30A)Current stability: ±0.2%Frequency range: DC to 8 kHzSwitching ControlSwitching controlled by external deviceRecommended transmitter controller: Zonge XMT-32Waveform type: Capable of virtually any type of pulsewaveform, limited by external controller deviceControlsPower ON/OFFTransmit/reset switchCurrent adjust pot, continuously adjustable, lockingVoltage range switch (50-250 V, 200-500 V, 450-750 V, 700-1000 V)Loop/dipole select switchDisplaysAnalog input voltage meter, 0-150 VAnalog output voltage meter, 0-1000 VPower on/off lamp, transmit lamp, output lampLCD:Output current (±0.01A)Input power (0-30KW)Transformer temperatureLoop turnoff time (microseconds)Indicator lamps: control power on, transmit on, transmitpolarityFault indicator lamps: output and input overcurrent, outputand input overvoltage, end of regulation, alternatorovervoltage, open circuitOutput JacksCurrent calibrate terminals (50 mV/A)Output current terminalsGrounding jackPowerThree-phase, 120 VAC, 400 HzRecommended motor generator set: Zonge ZMG-7.5Power connector: four-pin military screw-type withlocking ringOptionsSpare parts kit (standard and extended kits available)LCD heater for temperatures below - 15°C (+5°F)Current monitor isoamp moduleResistor load bankSwitch box for rapid switching of dipole pairsInternal timing board for specified IP-range frequencies30 amp outputSpecifications subject to change without notice© Copyright 1998, Zonge Engineering & Research Organization, Inc.Zonge Engineering and Research Organization, Inc.Offices:Arizona, Alaska, Nevada, Australia and ChileHeadquarters:3322 E. Ft. Lowell Road, Tucson, AZ 85716, USA (800) 523-9913Tel: (520) 327-5501 Fax: (520) 325-1588 Email: zonge@zonge.com,www.zonge.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!