<strong>Water</strong>-<strong>Ingress</strong>-<strong>Detection</strong>-<strong>System</strong>WIDS<strong>Weser</strong> <strong>Flow</strong> <strong>Control</strong> WIDS-Distribution BoxesThe distribution boxes are designed as sheet metal boxes for wall mounting outside the hazards areas.The doors are detachable hinged and equipped with a door looking system. The inlet for cables is viacable glands from the bottom.Basically equipped with components as listed below.• Suitable amount of cable glands for in and out going sensor cable.• Suitable amount of zener barriers.• Suitable amount of transducers or intrinsically safe circuits.<strong>Control</strong> Cabinet with local operator / control panelThe main control cabinet is equipped with all necessary control and monitoring devices. The localoperator panel is installed in the front door and is designed as an anodised alloy mimic panel, equippedwith all necessary indication and operating devices.The control cabinet is basically equipped with components as listed below.• Two incoming main feeder ~1AC,N,PE assembly basically consisting of main switch, fuses, networkmonitor (LED) and terminals.• Automatic change over power supply (main feeder 1 to feeder 2 und reverse)• Sub feeder assembly 24VDC with a suitable control voltage transformer240V /24V DC, fuses, Isolation monitor (only by IT-net work) and terminals.• PLC controller for I/O unit.• Suitable amount of analogue inputs 4-20mA on I/O unit for water ingress sensors• Suitable amount of digital inputs 24VDC on I/O unit for water ingress sensors• Set of digital In- and Outputs for general controls on I/O unit.• Alarm flash light and horn for water ingress alarms.• Alarm signal for power failure to alarm system• Signal interface to wheelhouse panel via terminals.• Signal interface to the main power cabinet via terminals.Remote Operator / <strong>Control</strong> panelThe operator panel in the wheelhouse is designed as mimic panel or as TFT Touch Screen panel both forflush mounting into an existing control console.The Mimic panel is basically equipped with components as listed below.• Specific mimic panel for operating the <strong>Water</strong> <strong>Ingress</strong> <strong>System</strong>, designed as a anodized alloy plateapprox. 500 x 500mm, basically equipped with:- LED’s yellow 10mm, for indicating water ingress alarms alarm stage 1- LED’s red 10mm, for indicating water ingress alarms alarm stage 2- Lamp test push button- <strong>System</strong> test push button- Rest push button (horn) with automatic reactivation.• Alarm flash light and horn for water ingress alarms.• Signal interface to the main control console via terminals.• The TFT Touch Screen panel uses an Ethernet interface.<strong>Weser</strong> <strong>Flow</strong> <strong>Control</strong> GmbH - Konsul-Smidt-Str. 8U, 28217 Bremen - Amtsgericht Bremen HRB 27110 HB ⋅ Geschäftsführer: Michael Borchers+49 (0) 421 877 54 40 +49 (0) 421 877 53 95 homepage: http://www.weser-flow-control.com e-mail: info@weser-flow-control.comBremer Landesbank (BLZ 290 500 00) 10 52 37 50 02 S.W.I.F.T.-Code BRLADE22 IBAN-Nr. DE84 2905 0000 1052 3750 02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!