X-VULCAN<br />

CHARACTERISTICS STANDARD SHADOW<br />

SUPPLY VOLTAGE:<br />

CURRENT CONSUMPTION QUIESCENT:<br />

CURRENT CONSUMPTION ALARM:<br />

ADDRESS RANGE:<br />

TONES:<br />

PROTECTION RATING:<br />

ADDRESSABLE SOUNDERS<br />

1 2 3 4 5 6 7 8<br />

ON<br />

OFF<br />

SWITCHES 1-5: REGULAR ADDRESSES FROM 094 TO 125 IN BINARY<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

Pr.Id.:32533<br />

PROGRAMMING DATA FOR ADDRESSABLE BASE SOUNDER<br />

17-40 V DC<br />

0.8 mA<br />

3.5 mA<br />

94 - 125 (32/Loop)<br />

SWITCH 6: OFF: IAS LOOP SOUNDER<br />

ON: APOLLO SOUNDER CIRCUIT CONTROLLER<br />

SWITCH 7 & 8: OFF: SWEEP SOUND (800 - 1000 Hz)<br />

SWITCH 7 ON & 8 OFF: ALTERNATE SOUND (2800 - 3500 Hz)<br />

SWITCH 7 OFF & 8 ON: ALTERNATE SOUND (800 - 1000 Hz)<br />

SWITCH 7 & 8: ON: CONTINUOUS (800 Hz)<br />

VULCAN ADDRESSABLE BASE SOUNDER Accepts APOLLO XP95 Detector Base.<br />

+<br />

17-40 V DC<br />

0.8 mA<br />

3.5 mA<br />

SHADOW (64/Loop)<br />

4 TONES SELECTED BY JUMPERS<br />

IP44<br />

1 2 3 4 5 6 7 8<br />

WEIGHT:<br />

75 grams<br />

DIMENSIONS:<br />

DIAM.: 112 - HEIGHT: 37 (mm)<br />

SOUND OUTPUT- CONTINUOUS 85 dB @ 1 METRE<br />

SOUND OUTPUT- SWEEP: 85 dB @ 1 METRE<br />

SOUND OUTPUT- ALTERNATING:<br />

SOUND OUTPUT- HIGH PITCH:<br />

85 dB @ 1 METRE<br />

92 dB @ 1 METRE<br />

This sounder is an ultra low power base sounder, intended to be used both as a stand-alone low profile<br />

sounder, or as a combined detector plus sounder assembly. When configured as a SHADOW sounder, by<br />

cutting the appropriate link, these sounders become invi<strong>si</strong>ble to the <strong>fire</strong> alarm control panel. This<br />

characteristic means that although the panel can control the activation of the sounders - in up to 32 groups per<br />

loop - each of these groups can have more than one and up to 64 sounders because the devices are not<br />

reporting back to the panel. This also means that device addresses 94 to 125, hereto reserved for<br />

addressable sounders, can be concurrently used by other device types, i.e. detectors and call points,<br />

meaning that at this stage the total numbers of sounders per loop is raised to 64 together with up to 125 other<br />

devices, detectors etc... This implies that the sounders are NOT monitored individually, but solely as part of<br />

the <strong>detection</strong> loop.<br />

13<br />

_<br />

_<br />

++ ++ _<br />

_<br />

X-VULCAN - A