06.08.2015 Views

IBM Storwize V7000

Storwize V7000 - Common Romandie

Storwize V7000 - Common Romandie

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>IBM</strong> Systems Storage<strong>IBM</strong> <strong>Storwize</strong> ® <strong>V7000</strong>Vincent BoucherIT Storage Specialist– <strong>IBM</strong> MontpellierSONAS – <strong>Storwize</strong> <strong>V7000</strong> vincent.boucher@fr.ibm.com<strong>IBM</strong> PSSC - Customer Center Montpellier© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation<strong>IBM</strong> Disk Portfolio 4Q2010BlockOptimized for ‘open systems’Optimized for z/OS and <strong>IBM</strong> iFileEnterpriseDS8000Mainframe and DistributedData Protection / ContinuousAvailabilityDisaster RecoveryBest Response Time in OLTPOptimized for capacity >50 TBXIVContinuous performanceSelf-tuning, self-healingSimple capacity managementThin provisioningOptimized for capacity >50TBSONASExtreme 100s of TB massivescalability for large scale NAS.MidrangeDS5000 Good cost/performance,general-purpose storage Need to add capacity to existingconfiguration 10s of TB of capacity<strong>Storwize</strong> <strong>V7000</strong> 10s of TB of rack-mountedstorage with sophisticatedsoftware functions Breakthrough ease of use andmanagement Non-disruptive migration from,or virtualization of, existing diskN seriesNAS or File SharingConcurrent unified file and blocksupportApplication integration –Exchange, SQL, VMware, SAP,OracleData protection and recoveryGateway for IP connect tocompetitive FC diskEntryDS3000Distributed/Remote office, low end,modularStorage OptimizersSVC, ProtecTIER, Information Archive, <strong>Storwize</strong> Appliances Storage technologies that add function, performance, ease of use, or efficiency to new or existing storage


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> OverviewModular Hardware Building BlocksSoftware inherited from prior Offerings plus EnhancementsSoftware inherited from SVC and DS8000 RAIDNew and enhanced Software functions RAID 0, 1, 5, 6, 10 New GUI (Easy-to-use, web based, XIV like) Storage Virtualization (Internal and external disks) Easy Tier TM SSD exploitation Non-disruptive Data Migration RAID & enclosure RAS services and diagnostics Global & Metro Mirror (Multi-cluster) Additional scalability improvements FlashCopy (256 targets,cascaded,incremental,Space Eff.) Enhanced Host, Controller and ISV interoperability Thin Provisioning Integration with <strong>IBM</strong> Systems Director Enhancements to TPC, FCM and TSM support5


© 2010 <strong>IBM</strong> CorporationAgenda <strong>Storwize</strong> V7K HW overview <strong>Storwize</strong> V7K SW overview <strong>Storwize</strong> V7K Management <strong>Storwize</strong> V7K Performance <strong>Storwize</strong> V7K information


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> HW OverviewEnclosure Front View – 12 Drive Bays2076-112/212Enclosure Front View – 24 Drive Bays2076-124/2248


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> OverviewDisks available300GB SAS450GB SAS600GB SAS1TB NL-SAS2TB NL-SAS300GB SSD SAS2.5-inch (SFF)10K RPM10K RPM10K RPM3.5-inch (LFF)7,200 RPM


© 2010 <strong>IBM</strong> CorporationEasy Tier <strong>Storwize</strong> <strong>V7000</strong> ConfigurationRAID 10SAS 10KRPM 300GBDB LogRAID 5 3+1SSD 73GB2 x RAID 5 8+1SAS 10KRPM 300GBHybrid PoolDB Data


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> HardwareBottom node canister.Notice the unit isidentical to the topcanister but installedupside down.Control Enclosure Rear View2076-112/124The power cooling module or PCMfor the control enclosure includesbatteries to protect the cache in thenode canisters. Notice the units areidentical except the unit on theright is installed upside down.Top node canister.Bottom expansioncanister. Notice theunit is identical to thetop canister butinstalled upside down.Expansion Enclosure Rear View2076-212/224The power cooling module or PCMfor the expansion enclosure doesnot include batteries and thus arenot interchangeable with controlenclosure PCMs. Notice the unitsare identical except the unit on theright is installed upside down.Top expansioncanister.11


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> HardwareControl Enclosure Rear View2076-112/124Expansion Four Two gigE 6Gbps 8Gbps ports slot SASfibreandforpossible chains two channel USB for future expansionports enclosuregrowthareenclosure to available provide expansion attachmentper more arenodeFCare available ports canister.or per 10Gig per nodeEthernet canister.ports.Expansion Enclosure Rear View2076-212/224Two 6Gbps SAS portsare available perexpansion canister forconnection to otherenclosures.12


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Cabling (supported configuration at GA)Drives in Control Enclosure are part of SAS Chain 2SAS Chain 2SAS Chain 1Supported but now we would have 3 enclosureson SAS Chain 2 and only one on SAS Chain 1Since each SAS Chain currently has onlyone enclosure we could add this secondexpansion enclosure to either Chain13


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Cabling - maximum configuration (post GA)14


© 2010 <strong>IBM</strong> CorporationInherit from SVC Recognized by many as Industry Leading Storage VirtualizationProduct in the Marketplace <strong>IBM</strong> has the most experience in Storage Virtualization in theIndustry SVC is a Open Storage Agnostic Solution …. SAN Volume Controller is a proven offering that has beendelivering benefits to customers for 6 years SAN Volume Controller demonstrates scalability with the fastestStorage Performance Council benchmark results SAN Volume Controller has the broadest Interoperability SAN Volume Controller and <strong>IBM</strong> <strong>Storwize</strong> <strong>V7000</strong> shares samekernel


© 2010 <strong>IBM</strong> CorporationVirtualized Storage All <strong>IBM</strong> <strong>Storwize</strong> <strong>V7000</strong> storage is virtualized Enables rapid, flexible provisioning and simple configuration changes Enables non disruptive movement of data among tiers of storage, including Easy Tier Enables data placement optimization to improve performance <strong>Storwize</strong> <strong>V7000</strong> also virtualizes external fibre channel storage Capacity from existing storage systems becomes part of <strong>Storwize</strong> <strong>V7000</strong> system Single user interface to manage all storage, regardless of vendor: improvesproductivity by up to double Virtualized storage inherits all <strong>Storwize</strong> <strong>V7000</strong> rich function including FlashCopy,Easy Tier, and thin provisioning Helps improve existing storage utilization up to 30% Improve availability by practically eliminating storage-related causes ofapplication downtime Migrate data from external storage to <strong>Storwize</strong> <strong>V7000</strong> storage or keepexternal storage as part of <strong>Storwize</strong> <strong>V7000</strong> system long-term Extends life and enhances value of existing storage assets Supports storage systems from <strong>IBM</strong>, EMC, HP, Sun/Oracle, Hitachi,NetApp, Fujitsu, Bull, Compellent, NEC, Pillar, and moreExternalVirtualization


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> OverviewWhat we will have with <strong>Storwize</strong> <strong>V7000</strong>:Server Server Server ServerServer Server ServerTPCTPCSVC SW<strong>Storwize</strong><strong>V7000</strong>FCMFCM<strong>IBM</strong>MMorGMTPCTPCSVC SW<strong>Storwize</strong><strong>V7000</strong>FCMFCM<strong>IBM</strong>HPEMC<strong>IBM</strong>SunHDS19 <strong>V7000</strong> to <strong>V7000</strong> replication supported Cannot currently replicate between a <strong>V7000</strong> and a SVC cluster <strong>V7000</strong> cannot virtualize another <strong>V7000</strong> Can virtualize any storage system SVC supports and map volumes to any hosts SVC supports Future direction is peer-to-peer support <strong>V7000</strong> replication to SVC and vice versa Cluster up to four <strong>V7000</strong>s together


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Features: ScalabilityDynamically scale …… performanceSCALABILITY For performance sensitive applications,dynamically add more performance toyour existing capacity by adding SSDs. Cluster <strong>V7000</strong>s (Future Direction)… capacity For high capacity applications such asarchive, dynamically add capacity byadding internal expansion enclosures orexternal storage systems Cluster <strong>V7000</strong>s (Future Direction)… features20FlashCopySAN VisualizationPerformance managementMetro Mirror / Global MirrorAutomated Data RelocationPractice DR recoveryAutomated failover / fail-backThin ProvisioningPerformance optimizationVirtualization Many features are included. Software is preinstalled in the system andmanagement console for easy setup. Premium features are already installed


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Features: Migration and HighAvailabilityTransparent datamovementLocal MirrorLegacyNetworkApplicationserverMIGRATION Efficiently managetechnology upgrades andlease terminations bytransparently movingapplication data fromlegacy disk arrays to the<strong>Storwize</strong> <strong>V7000</strong>. For ultra-high availability applications,synchronously mirror application data betweentwo separate disk enclosures attached to thesame <strong>Storwize</strong> <strong>V7000</strong> system.21


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Features: EfficiencyThin provisioningEFFICIENCY22Without thin provisioning, pre-allocatedspace is reserved whether theapplication uses it or not.Performance optimizationHot-spots due to poor data layoutHot-spots due to poor data layoutDynamicgrowthWith thin provisioning, applications cangrow dynamically, but only consume spacethey are actually using.(Via TPC)TransparentreorganizationEasy Tier TM SSD sub-Volume ExploitationOptimized performance and throughputSSDs HDDs SSDs HDDsAutomaticRelocationOptimized performance and throughput More productive use ofavailable storage. Works across all supportedhost platforms and allsupported external storagesystems. Analyze system performanceand throughput. Transparently rearrange thedata to eliminate hot-spotsand balance utilization of allcomponents.(same as being delivered on DS8K – same code) Busiest data extents areidentified and automaticallyrelocated to highest performingSolid State Drives Remaining data extents cantake advantage of highercapacity, price optimized drives


© 2010 <strong>IBM</strong> CorporationEasy Tier Process<strong>Storwize</strong> <strong>V7000</strong> NodeVolumeEasy Tier CodeDPIOM DMP DMAA “hot spot” is formed on a magnetic diskwhen an application makes frequent use ofthe same area or extent of a volumeThe I/O Monitor captures access patterns andgenerates usage statistics sending them tothe Data Placement AdvisorThe Data Placement Advisor identifies hotspots and outputs potential data migrations tothe Data Migration PlannerThe Data Migration Planner performs analysisto deliver recommended data migration planto the Data Migrator based on the physicalstorage characteristicsData Migrator confirms and schedules datamigration activity based on the data migrationplan using SVC function to seamlesslyrelocate the data to higher performing storage(SSD) without any application interruptionMagnetic Disk23SSD


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Easy Tier Application Transaction ImprovementApplicationTransactions240% fromOriginalbrokeragetransactionPRELIMINARYEasy TierLearningEasy TierIn Action12 hours (Elapsed Time)


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> EasyTier Application Transaction ImprovementPRELIMINARYTransactionAverageResponseTimeEasy TierLearningEasy TierIn Action12 hours (Elapsed Time)


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Features: AvailabilityFlashCopyAVAILABILITYFlashCopy ManagerUp to 256Up to 256 Create instant application copiesfor backup or application testing. Make better use of space withincremental (only changed blocks)or space-efficient (thin provisioned)snapshots. Integrated, instant copy for criticalapplications Virtually eliminate backupwindows Rapidly create clones forapplication testing View inventory of applicationcopies and instantly restore26


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Features: Business ContinuanceMirror data off-siteBUSINESSCONTINUANCENetworkPractice recovery procedures(Via TPC-R) Synchronously over Metro distances. Asynchronously over Global distances. Application-level consistency groups. For critical application consistencygroups, freeze the Mirror and take aconsistent FlashCopy.NetworkRecoverypracticevolume Practice application recovery proceduresfrom the FlashCopy.Automate response to disasters(Via TPC-R)NetworkRecoveryvolume Automate failover to Recovery volume. Execute practiced application recoveryprocedures. Automate fail-back after repair.27


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Features: Manageability (provided by TPC)Visualize the SAN(Via TPC)MANAGEABILITYNetwork From virtual machines to the physical serverthey reside on, through the SAN, to thevirtual and physical disk systems … Physical topology and logical data path. Health/Status Monitoring. Event Management. Device Capacity Management. Policy-based Alerting.Analyze performance(Via TPC)Network Isolate application I/O performanceproblems. Report on performance history.28


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Advanced Functions Thin Provisioning – Included Allows for storage optimization by consuming real capacity only when data is written FlashCopy – Included Allows use of FlashCopy function with internal <strong>Storwize</strong> <strong>V7000</strong> volumes as well asexternal storage under <strong>Storwize</strong> <strong>V7000</strong> management Up sell opportunity: FlashCopy Manager Easy Tier – Included Allows for management of hotspots automatically by migrating extents fromspinning drives to solid state drives as needed for higher performance Up sell opportunity: TPC for Disk Midrange Edition Metro and/or Global Mirror – Optional Allows you to replicate data synchronously or asynchronously between <strong>Storwize</strong><strong>V7000</strong> systems Up sell opportunity: TPC for Replication External Virtualization – Optional Allows you to bring external fibre channel disk systems under <strong>Storwize</strong> <strong>V7000</strong>control providing access to all the functions of the <strong>V7000</strong> virtualization software


© 2010 <strong>IBM</strong> Corporation<strong>IBM</strong> <strong>Storwize</strong> V7K strength Easy to use GUI (from the XIV) Scalability, start small one controller enclosure and grow to 120 drives or 120 TB capacity atGA. All the SVC features: Virtualization, Thin Provisioning, FlashCopy, Remote Replication (MetroMirror & Global Mirror), Easy Tier, External Virtualization, Provisioning,Dynamic Migration, Local Mirror Providing reel solutions integration into <strong>IBM</strong> System Director, FlashCopy Manager, TSM,ProtecTIER, TPC 2.5” and/or 3.5” SAS-2, 6 Gb/s drives and technology Solid State Drive (SSD) support with improved utilization byEasy Tier Interoperability matrix as the SVC 6.1


© 2010 <strong>IBM</strong> CorporationAgenda <strong>Storwize</strong> V7K HW overview <strong>Storwize</strong> V7K SW overview <strong>Storwize</strong> V7K Management <strong>Storwize</strong> V7K Performance <strong>Storwize</strong> V7K Information


© 2010 <strong>IBM</strong> CorporationFresh New User Interface Based on XIV GUISystemrecommendationsVisual task flowguidanceIntegrated videoinstructionLink to moreinformation if neededSystem statusalways available32


© 2010 <strong>IBM</strong> CorporationFresh New User Interface Based on XIV GUICreate Storage PoolCreate Volumes


34© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation


Offline© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> CorporationOptions for Managing <strong>Storwize</strong> <strong>V7000</strong>1. Out of the box management – Browser based, included with storage– Applies to: <strong>Storwize</strong> <strong>V7000</strong> (other storage devices have their own GUI)– Usage: Midmarket client for simple and basic configuration and management– Value: Simple single device setup and managementAdmin2. Complex, Value-Add Storage Management – TPC– Applies to: <strong>IBM</strong> (and non-<strong>IBM</strong>) storage – TPC-MRE priced for midrange– Usage: Complex storage environments with dedicated storage administrators– Value: End-to-end storage management with advanced storage management valueStorage Admin3. Integrated <strong>IBM</strong> Server and Storage Management - Systems DirectorTPC<strong>IBM</strong> DS8000<strong>IBM</strong> SVC<strong>IBM</strong>DS3000DS4000DS5000<strong>IBM</strong>TS3500TS3310– Applies to: Internal and external <strong>IBM</strong> storage <strong>IBM</strong> Servers (Power, X, BladeCenter)– Usage: Clients with System administrators who cover both Server and Storage Mgmt– Value: Manage all the <strong>IBM</strong> servers and Storage devices from one pane glass“Systems” Server/Storage AdminSystems Director+TPC<strong>IBM</strong> DS8000<strong>IBM</strong> SVC<strong>IBM</strong>DS3000DS4000DS5000<strong>IBM</strong>TS3500TS3310


© 2010 <strong>IBM</strong> CorporationAgenda <strong>Storwize</strong> V7K HW overview <strong>Storwize</strong> V7K SW overview <strong>Storwize</strong> V7K Management <strong>Storwize</strong> V7K Performance <strong>Storwize</strong> V7K Information


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Performances Performance is becoming much less important to our target market, but…… <strong>Storwize</strong> <strong>V7000</strong> performance should be outstanding Roughly double performance capability of CX4-480TB R1.0 <strong>IBM</strong> DS5020 <strong>IBM</strong> DS5300EMC CX4-480HDSAMS1000HP EVA8100MS ESRP TBD 28,000 55,000 42,000 25,000 20,000Cache Reads (IOPS) 900,000 200,000 700,000 400,000 210,000Disk Reads(IOPS)Disk Writes(IOPS)Ext FC 400,000SSD 320,000HDD 70,000*Ext FC 145,000SSD 70,000HDD 24,000*50,000 98,000 43,950 >54,0009,500 25,000 24,200Cache Reads (MB/s) 6,000 6,400 3,000 1,600 1,600Disk Reads (MB/s) 6,000 1,600 6,000 1,420 1,500Disk Writes (MB/s) 4,000 1,100 4,000 1,600 870 1,00043•* Disk limited


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Performances With a full configuration of HDDs, <strong>Storwize</strong> <strong>V7000</strong> can deliver up to70,000 IOPS for disk reads with a throughput estimated at6,000MB/s and up to 24,000 IOPS for disk writes with a throughputestimated at 4,000MB/s. Configured with just 32 SSDs, these numbers skyrocket to 320,000IOPS for reads and 70,000 IOPS for writes.


Storage Performance Council – Benchmark #1© 2010 <strong>IBM</strong> Corporationhttp://www.storageperformance.org/results/benchmark_results_spc1/#spc1


© 2010 <strong>IBM</strong> CorporationStorage Performance Council – Benchmark #1SPC-1 IOPSTM (higher is better)700006000050000IOPS4000030000SPC-1 IOPSTM2000010000Price/performance16141210864200<strong>Storwize</strong> V7K DS5020 DS5300 (FDE)configurationPrice Performance (lower is better)<strong>Storwize</strong> V7K DS5020 DS5300 (FDE)Name<strong>Storwize</strong> <strong>V7000</strong> has the lower price performance ratioANDAll NO ADDITIONAL fee is require for:1. Flash Copy2. Thin Provisioning3. Easy TierPrice PerformanceThis price performance ratio DOES include theExternal License Virtualization fee


© 2010 <strong>IBM</strong> CorporationEnergy47


© 2010 <strong>IBM</strong> CorporationEnergy Configured with 12x 2TB drives, the 12-bay controlenclosure consumes only 665W, or 27.67 Watts/TB. Configured with 24x 600GB drives, the controlenclosure consumes just 680W, or 47.2 Watts/TB,delivering double the number of read/write heads in thesame energy envelope.


© 2010 <strong>IBM</strong> CorporationWarranty and Support49


© 2010 <strong>IBM</strong> Corporation50<strong>Storwize</strong> <strong>V7000</strong> HW Warranty is 3-year 9x5 Next Business Day (NBD) Warranty service upgrade options● 24x7 two-hour or four-hour onsite response● 9x5 four-hour onsite response. Maintenance extensions for additional years beyond 3 years Each MTM/serial number has unique maintenance price and assumes full drivecapacity Feature code-level maintenance price for solid-state drives SW PID includes first year of Subscription and Support Additional years available at annual renewal and pre-purchase at initial sale● Includes free upgrades, defect support and how-to help Customer Replaceable Unit (CRU) and spare parts strategy CRUs should be defined for:● Power/Cooling Modules (PCM)● Drives● Node canisters● Expansion canisters● Enclosure with backplane Customer consumable possibly● PCM Battery


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> What is support structure Who do you call HW versus SW support and how does that work● Call 800-<strong>IBM</strong>-SERV, option 1 for HW, option 2 for SW Who installs HW and does MESs Customer installable and maintainable Who installs SW and does code upgrades Customer installable and maintainable SW maintenance includes: Problem determination/resolution, how-to help, software upgrades Get customer to sign up for automatic notification ofFLASHes, upgrades etc. using “My Notifications” service Activate call home and inventory reporting51


© 2010 <strong>IBM</strong> CorporationAnalyst Reports52


© 2010 <strong>IBM</strong> CorporationAnalyst reports“ <strong>IBM</strong> has now introduced <strong>Storwize</strong> <strong>V7000</strong>, specifically designed to meet the growing scalabilityrequirements of the mid-sized datacenter, including functionality features usually only foundonly in the largest enterprises.<strong>IBM</strong>’s range of storage solutions just got even better! ““<strong>IBM</strong> <strong>Storwize</strong> <strong>V7000</strong> empowers the datacenter with enterprise-class software capabilities,integrated into the basic platform, many of which are included in the basic price of the platform.With a completely new GUI from XIV, replication and virtualization capabilities normally foundonly in higher-priced enterprise arrays, and management capabilities that simplify complextasks, <strong>IBM</strong> <strong>Storwize</strong> <strong>V7000</strong> provides the IT staff with enterprise features at a mid-range price.”“One thing is for sure, if you are managing a mid-sized datacenter with a rapidly expandingdata store, and a not-so-rapidly expanding budget and administrative staff, you need to look at<strong>IBM</strong>’s <strong>Storwize</strong> <strong>V7000</strong>, as one sure way to put a stop to a rising TCO.”Full document link


© 2010 <strong>IBM</strong> CorporationAnalyst reports“Solid state drives (SSDs) are a hot topic of interest in IT organizations because of theirpotential to turbocharge storage performance.One inhibitor to adoption has been the high cost of SSDs relative to hard disk drives (HDDs)and a second has been the problem of when and how to use SSDs efficiently and effectively.<strong>IBM</strong> <strong>Storwize</strong> <strong>V7000</strong> users now have the tools in Easy Tier and its associated software toolStorage Tier Advisor to evaluate the benefits of, plan for, deploy, and manage on an ongoingbasis SSDs in combination with existing HDDs. It’s not for nothing that <strong>IBM</strong> calls its productEasy Tier.”Full document link


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Summary55


© 2010 <strong>IBM</strong> Corporation<strong>IBM</strong> <strong>Storwize</strong> <strong>V7000</strong> Values Very compact packaging: controllers and disk in just 2U Half to one-third rack space required by EMC CLARiiON CX4-240 Completely new GUI based on well-received XIV GUI Provision a volume in as few as six clicks; setup system in as few as ten clicks Proven to be very easy even for novice users in UCD tests Enterprise-class capability Sophisticated local and remote mirroring Integrated server and storage management High performance in a midrange disk system Up to almost 1M IOPS (cache read) Up to 82,000 IOPS for “database-like” 70/30 R/W workload Integrated Non-disruptive migration function Speeds time-to-value from weeks or months to just days Minimizes downtime for migration Eliminates cost of add-on migration tools Integrated no-charge Easy Tier function Application throughput improved up to 240%, up to 30% improved response time Integrated no-charge Thin provisioning function Reduce disk capacity required by 20% or more; reduce disk capacity for copies by 75% ormore Similar benefits to SVC when virtualizing external storage


© 2010 <strong>IBM</strong> Corporation<strong>Storwize</strong> <strong>V7000</strong> Web site57


<strong>Storwize</strong> <strong>V7000</strong> Web site© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> Corporation


© 2010 <strong>IBM</strong> CorporationFutures61


© 2010 <strong>IBM</strong> CorporationPlanned EnhancementsEnhancements planned for 2011 deliveryClustering up to 4 <strong>Storwize</strong> <strong>V7000</strong> controllers togetherLow bandwidth replication enhancementsFactory rack and stackFC direct attach to Host Servers10 Gb iSCSI and FCoEDynamically grow array and change RAID typeReplication over native IP linksReplication between <strong>Storwize</strong> <strong>V7000</strong> and SVCReplication on volumes >2TBExploit VMware VAAI and ISV unique APIs


© 2010 <strong>IBM</strong> CorporationQ&A Time63


Notice, Disclaimer, and Trademark InformationCopyright © 2010 by International Business Machines Corporation.© 2010 <strong>IBM</strong> CorporationNo part of this document may be reproduced or transmitted in any form without written permission from <strong>IBM</strong> Corporation.Product data has been reviewed for accuracy as of the date of initial publication. Product data is subject to change without notice. This informationcould include technical inaccuracies or typographical errors. <strong>IBM</strong> may make improvements and/or changes in the product(s) and/or programs(s) atany time without notice. Any statements regarding <strong>IBM</strong>'s future direction and intent are subject to change or withdrawal without notice, andrepresent goals and objectives only.References in this document to <strong>IBM</strong> products, programs, or services does not imply that <strong>IBM</strong> intends to make such such products, programs orservices available in all countries in which <strong>IBM</strong> operates or does business. Any reference to an <strong>IBM</strong> Program Product in this document is notintended to state or imply that only that program product may be used. Any functionally equivalent program, that does not infringe <strong>IBM</strong>'sintellectually property rights, may be used instead. It is the user's responsibility to evaluate and verify the operation of any on-<strong>IBM</strong> product, programor service.THE INFORMATION PROVIDED IN THIS DOCUMENT IS DISTRIBUTED "AS IS" WITHOUT ANY WARRANTY, EITHER EXPRESS OR IMPLIED.<strong>IBM</strong> EXPRESSLY DISCLAIMS ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE ORNONINFRINGEMENT. <strong>IBM</strong> shall have no responsibility to update this information. <strong>IBM</strong> products are warranted according to the terms andconditions of the agreements (e.g., <strong>IBM</strong> Customer Agreement, Statement of Limited Warranty, International Program License Agreement, etc.)under which they are provided. <strong>IBM</strong> is not responsible for the performance or interoperability of any non-<strong>IBM</strong> products discussed herein.The provision of the information contained herein is not intended to, and does not, grant any right or license under any <strong>IBM</strong> patents or copyrights.Inquiries regarding patent or copyright licenses should be made, in writing, to:<strong>IBM</strong> Director of Licensing<strong>IBM</strong> CorporationNorth Castle DriveArmonk, NY 10504-1785U.S.A.TrademarksThe following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both. Other company,product, and service names may be trademarks or service marks of others:<strong>IBM</strong>, the <strong>IBM</strong> logo, ON (logo) DEMAND BUSINESS, DB2, Enterprise Storage Server, FlashCopy, POWER5, Tivoli, TotalStorage, TotalStorageProven, System Storage, System p, System i, System x, System z, AIX, eServer, xSeries, pSeries, iSeries, zSeries, and BladeCenter64

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!