<strong>SERIES</strong> <strong>4000</strong><strong>EXPOSED</strong> <strong>THERMOSTATIC</strong> <strong>SHOWER</strong><strong>MIXING</strong> <strong>VALVE</strong>COMPLETE APPLICATION FLEXIBILITY(Type T) senses outlet temperature and compensates for fluctuation inincoming hot and cold water temperatures and/or pressure to stabilizeoutlet temperature.Lawler Manufacturing Co. Inc., www.lawlervalve.com


Lawler Series <strong>4000</strong>Thermostatic Shower Mixing ValveThe SolutionThe LAWLER <strong>SERIES</strong> <strong>4000</strong> Mixing Valveautomatically responds to temperature andpressure variations in hot and cold water lines.The stainless steel piston and liner preciselyproportions water flow to maintain a constantoutlet temperature.The Series <strong>4000</strong> controls shower and bath watertemperature to guard against unexpectedhot or cold water spikes. Lawler ThermostaticShower Valves are a natural choice for homes,motels, hotels, institutions, hospitals, clubs,and anywhere safe, comfortable showeringis required.Anti-Scald and Anti-Chill ProtectionLawler’s Series <strong>4000</strong> Valve guards against thepossibility of injury due to scalding. Should thecold water supply fail, the valve shuts downflow through the hot water inlet port. Chillingby cold water is also prevented since flowthrough the cold water inlet port is reducedif the hot water supply should fail. Only athermostatically operated valve can providescald-free/chill-free protection.Complete Application FlexibilityThe Lawler Series <strong>4000</strong> is available in manystyles and combinations to meet your fieldrequirements in the temperature control ofwater. Bronze, brass, copper, and stainlesssteel construction assures years of dependable service.The valve body is designed with a flat wallmounting flange so that the valve can beeasily mounted onto a shower wall, spa tub,or cabinet assembly.PRESSURE DROP, POUNDS PER SQUARE INCHFLOW CAPACITIES FLOW CAPACITIES SINGLE STAGE SINGLE - <strong>SERIES</strong> STAGE 3000 - <strong>SERIES</strong> 3500 3800 <strong>4000</strong>& <strong>4000</strong>7060504540353025201510981/2″ LOW7651 2 3 4 5 6 7 8 9 10 15 20 30 35FLOW OF WATER, GALLONS PER MINUTE* Standard valve is 1 / 2″ medium flowCAPACITIES – GPM <strong>SERIES</strong> <strong>4000</strong>Pressure Drop PSI 5 10 20 30 45Valve Size1/2″ MED1/2″ HIGH3/4″ HIGHCapacity-GPM1/ 2″ 1.5 2.0 3.0 4.5 5.53/ 4″ 5.0 8.0 10.5 15 20CAPACITIES – LPM <strong>SERIES</strong> <strong>4000</strong>Pressure Drop PSI 5 10 20 30 45Valve SizeCapacity-LPM1/ 2″ 5.7 7.5 11.4 17.0 20.8Making shower valves for over 60 years.3/ 4″ 18.9 30.3 39.7 56.7 75.7


Model 82306Model 85002Model 85020Model 85005DIMENSIONS:A B CN.P.T. N.P.T. INLETS1/ 2″ 1/ 2″ 8 1 / 2″Lawler Series <strong>4000</strong>Thermostatic Shower Mixing ValvesBenefits• Senses and compensates for thetemperature/pressure fluctuations (up toa 20% drop in inlet supply pressure).• Maintains temperature to +– 3°F.• Protects against scalding and chilling.• Offers choice of temperature settingsfrom full cold through 110°F.• Easy maintenance and repair.• Backed by Lawler’s One Year Warranty.Features• Liquid-filled thermostat.• Color-coded temperature dial.• Bronze and stainless steel construction.• Temperature range of 85°F to 135°F.• Factory tested and set at 110°F.• Flow rates of 5, 10 & 20 GPM at 45 psi.• Inlet piping size of 1/2″ or 3/4″.• Bronze or polished chrome finish.• ADA approved lever handle.• Optional stop and checks.• Vandal-resistant handles available.• Variety of accessories available.Thermostatic ActuatorSenses Slight Temperature VariationsThe Lawler thermostat consists of a hydraulicallyformed bellows of the liquid filled type.This thermostat is linear in its expansion andexerts the highest possible operating force directlyto the valve piston. Hot and cold waterinlets must have a minimum 15°F differentialfrom outlet set temperature.Piston AssemblyOnly Moving PartThe piston, liner, and springs are all constructedof stainless steel. Sliding parts arepolished or mirror finished for friction freedurability. The piston is the only moving partof the valve. All assembly units, including thepiston and liner, are easily removed for cleaningand inspection.Every Lawler valve is tested in the factorybefore being shipped to the customer.3/ 4″ 3/ 4″ 9 1 / 2″


5330 East 25th StreetIndianapolis, Indiana 46218Phone (317) 261-1212Fax (317) 261-1208EventHot Water Cold Water Cold WaterPressure Drops Pressure Drops Pressureby Half by Half Completely LostCold Inlet 60°FHot Inlet 120°FSet Temp 100°FHot Inlet Increasesto 160°FStandard Two Temperature Temperature Full Hot Water TemperatureHandle Valve Drops Greatly Increases Greatly Flows Increase to 127°FPressure Temperature is Temperature is Small Flow of TemperatureBalanced Valve Maintained ± 2°F Maintained ± 2°F Hot Water Increase to 127°FThermostatic Temperature May Temperature May All Flow Temperature WillValve Drop 1-2°F Drop 1-2°F Shuts Off Drift Up 1-3°FCombinationPressure Balanceand ThermostaticValveTemperature Temperature All Flow Temperatureis Maintained is Maintained Shuts Off Will Drift Up 1-3°F