09.08.2015 Views

Trailing Cables

Trailing Cables - Hi-Tech Controls

Trailing Cables - Hi-Tech Controls

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

~HI-TECH~ CONTROLS, INC.(800) 677·8942 I (303) 680·5159Click or Call for a Quotelwww. h itech controls .com<strong>Trailing</strong> <strong>Cables</strong><strong>Trailing</strong> cables are used for high mechanical stress,especially for applications with frequent windingand unwinding with simultaneous tensile andtorsional stress.<strong>Trailing</strong> cables are frequently used in buildingmachinery, conveyors and lifting systems, andcranes.C HELUKABEL


~HI-TECH~ CONTROLS, INC.TROMM·PUR·H(800) 677·8942 I (303) 680·5159Click or Call for a Quoteltrailing, halogen-freewww. h itech controls .comHELUKABEL • TROMM-PUR-H ((IRoHSITechnical data• <strong>Trailing</strong> cable ace. to Ul AWM Style 20235CSA/AWM• Temperature rangeflexing -40 oc to +80 ocfixed installation -50 oc to +80 oc• Nominal voltageace. to VDE 600/1000 vace. to Ul1000 V• A.c. test voltage, 50 Hzcore/core 4000 v• Insulation resistancemin. 20 MOhm x km• Tensile strength s. table• Speed of motionup to 250 m/min• Minimum bending radiusapprox. 6x cable 0ApplicationCable structure• Bare copper, extra fine wire conductor toVDE 0295 cl. 6 and IEC 60228 cl. 6• TPE core insulation• core colours up to5 cores ace. to DIN VDE 0293.6 or more cores black with white numbers+ gnye• cores stranded around support element• Polyester f leece wrapping• High-tensile PUR double sheath withintegrated support braiding• Sheath colour yellowProperties• PUR outer sheath, low adhesion. abrasionresistant. halogen-free, resistant to UV, oil,hydrolysis and microbial attack• PUR sheath: self-extinguishing and f lameretardant according to VDE 0482-332-1-2.DIN EN 60332-1-2/ IEC 60332-1 <strong>Trailing</strong> cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneoustensile and torsional stress, for building machinery, conveyors and lifting systems, and cranes. They are used as robust and all-weatherresistant cables in the harshest operating environments in mining and in flexible handling equipment and railway motors. The cables aresuitable for installation in dry, damp and wet environments, as well as outdoors.Notes• During installation and operation the tensile stress on the cable must not exceed 15 N/mm 2• Acceleration must not exceed 0.4 m/sec 2• 1 to 2 turns should remain on the drum during operationC € =The product is conformed with the EC Low-Voltage Directive 2006/95/EG.Part no. No.coresx Outer B Cop. Weight Part no. No.coresx Outer B Cop. Weightcross-sec. approx. mm weight approx. approx. mm weight approx.mm• kg/km kg/ km kg/km kg/ km77144 4 G 1.5 10.2 58.0 157.0 154.0 270.077145 5 G 1.5 10.8 72.0 176,0 192.0 362,077146 7 G1.5 12.9 101.0 245,0 230.0 409.077147 12 G 1.5 18.4 173.0 337.0 288,0 511,077148 18 G 1.5 18.6 259.0 526.0 384.0 633.077149 24 G 1.5 21,3 345.6 662.0 480.0 766.0771 50 30 G 1.5 24.6 432.0 901.0 614,0 936.077151 42 G 1.5 26.5 604.8 1056.0 768,0 1170.0771 52 4 G 2.5 11.7 96.0 208.0 960,0 1485,077153 5 G 2.5 12.7 120.0 263.0 1344.0 2115.077154 7 G 2.5 14.8 168.0 327.0 1920.0 2600.077155 12 G 2,5 20.4 288,0 533,0 2688,0 3700,0771 56 18 G 2.5 21.1 432.0 725,0 3648.0 4800:077157 24 G 2,5 24,8 576,0 988.0 4608.0 5900,0771 58 30 G 2.5 27.6 720.0 1242.05760.0 7100,077159 40 G 2.5 30.0 960.0 1500.077160 50 G 2.5 34.3 1200.0 1800.0Dimensions and specifications m ay be changed without prior notice.C HELUKABEL


~HI-TECH~ CONTROLS, INC.(800) 677-8942 1 (303) 680·5159 www.hitechcontrols.comClick or Call for a QuotelTROMM-PUR PUR trailing and control cable, halogen-freeIELUKABEL TROMM-PUR 12G1 QMM /218038 3CIMJOO Y 001042788 ( €RoHSTechnical data• Special PUR insulation and jacket• Adapted to DIN VDE 0250• Strain bearing support strand• Temperature range-40 oc to +80 oc(up to +100 oc for short periods>• Nominal voltageup to 1 mm 2 Uo/U 300/500 Vas of 1 ,5 mm 2 Uo/U 450/750 V• Test voltageup to 1 mm 2 = 2000 vas of 1,5 mm 2 = 2500 v• Breakdown voltageup to 1 mm 2 = 4000 vas of 1.5 mm 2 = 5000 v• Insulation resistancemin. 20 MOhm x km• Minimum bending radiusapprox. 10x cable 0• Radiation resistanceup to 100x10 6 cJ/kg (up to 100 MradlApplicationCable structure• Bare copper, fine wire conductors. bunchstranded to DIN VDE 0295 cl. 6. col. 4,BS 6360 cl. 6 and IEC 60228 cl. 6• Special core insulation, PUR• Support core• Core coding to DIN VDE 0293 (flexiblecables>• Cores stranded in layers with optimallay-length• Core wrapping with f leece• Support braiding of synthetic fibres• Halogen-free outer jacket PUR• colour orangeProperties• High flexibility at low temperatures• usable for foodstuffs• Abrasion and tear resistant• Loadable under torsional stressResistant to• Oils and fats• Non-alcoholic fuels and kerosene• Atmospheric influences• UV-radiation• Oxygen and ozone• Microbes and rotting• Sea and waste water• VibrationsNote• G = with green-yellow earth core.• AWG sizes are approximate equivalentvalues. The actual cross-section is in mm 2 .TROMM-PUR has taken the development of the neoprene type cables one step further. It is a robust. all-weather cable. halogen-free, tearand abrasion resistant and suitable for use in drag-chains. in ship docks. on building sites. for conveyor systems, in mining, for tunnels androadbuilding.For the connecting the ski lift terminal positions to the control unit. surveillance of the joining rods in ski lift cables, as feeder cables forvery high currents as for example in pump engineering, mining, locomotive and rail-carriage construction, for oil rig platforms, emergencypower generators etc.C E =The product is conformed with the EC Low-Voltage Directive 2006/95/EG.Part no. No.coresx outer" Weight Breaking straincross-sec. approx. mm approx. kg / km ca. kpAWC·NO.mm•2603S 14 G 0,75 16.5 25026036 12 G 1 17,5 50026037 18 G 1 23,0 50026038 3 G 1,5 9,5 20026039 5 G 1.5 12,5 20026040 7 G 1,5 15.5 25026041 12 G 1,5 21,0 75026042 18 G 1.5 27,0 75026043 24 G 1.5 30,0 75026044 30 G 1.5 34,0 75026045 42 c 1,5 40,0 75026046 4G2,5 14,0 20026047 5 C2,5 15,0 25026048 7G2,5 18,0 30026049 12 c 2,5 25.0 75026050 24G 2,5 36.0 75026051 30C 2.5 40.0 75026052 36C 2.5 44.0 75026053 7C4 22.0 50026054 4 G 10 22.0 50026055 4 c 16 27,0 50026059 5 c 16 34.0 75026056 4C25 30.0 50026057 4 c 35 36,0 100026058 4 C50 42.0 1000Dimensions and specifications may be changed without prior notice. !RC01lC HELUKABEL


~HI-TECH~ CONTROLS, INC.(800) 677·8942 I (303) 680·5159Click or Call for a Quotelwww. h itech controls .comNSHTOU drum cable. VDE approvedTechnical data• Special-crane-drum cable to DIN VDE 0250part 814• Temperature rangeflexing -35 oc to +70 ocfixed installation -40 octo +70 oc• Max. conductor temperatureunder load +60 occircuit conditions +200 oc• Nominal voltage Uo/U 0,6/1 kV• Max. permissiblenominal voltagesfor t hree phase and one phase a.c.current installation Uo/U 0,7/1,2 kVfor direct current Uo/U 0,9/1,8 kV• Test voltage 2500 V• Insulation resistancem in. 10 MOhm x km• Minimum bending radius7,5x cable 0• Radiation resistanceup to 20x106 cJ/kg (up to 20 MradlCable structure• Tinned copper fine wire conductors. bunchstranded to DIN VDE 0295 cl. 5, BS 6360 cl.5 and IEC 60228 cl. 5• Rubber core insulation Gl1 to DIN VDE 0207part 20• Core identification to DIN VDE 0293, 6 coresand above with numbering• Cores stranded (without elongated centralcorel with max. lay-length of 8x0 over thestranding lavers• Textile tape• Textile braiding as protection againsttorsion. embedded in inner filling sheath• Neoprene outer jacket. type 5GM2 to DINVDE 0207 part 21• Jacket colour blackProperties• Designed and developed for horizontaldrum-operation• Permissible running speed up to120m/min max.• Polychloroprene-rubber (neoprenel-jacket.extremely cold resistant• Behaviour in fireTest according to 0482-332-1-2. DIN EN60332-1-2/ IEC 60332-1 (equivalentDIN VDE 0472 part 804 test method Bl• Oil resistantTest according to VDE 0472 part 803, testmethod A• Due to the neoprene outer jacket, t hecables is resistant against ozone andradiation, oils. acids, fats, gazoline. solventsand chemicals• During the installation and operation thetensile stress on conductor may notincrease 15 N/mm2• Accelaration not more than 0.4 m/sec 2• During operation, 1-2 convolutions shouldremain on the operating drum• In case of high mechanical stress. especiallyof high dynamic tensile stress result highaccelaration, the permissible stress mustbe defined in each caseApplicationNote• G =with green-yellow earth core.• AWG sizes are approximate equivalentvalues. The actual cross-section is in mm 2 •<strong>Trailing</strong> cables are used for high mechanical stress. especially for applications with frequent winding and unwinding with simultaneous tensileand torsional stress. for building machinery, conveyors. shifts and cranes.They are used as robust and all weather resistant cables of roughest operations in mining and in flexible handling equipment and railwaymotors. The cables are suitable for outdoor installation in drv. damp and wet places as well in open air.For applications which go beyond standard solutions we recommend that vou fill out our especially developed questionnaire for reelingcables. Please read the installation instructions.C E= The product is conformed with the EC Low-Voltage Directive 2006/95/EG.Part no. No.cores x Outer B Cop. Weight AWG·NO. Part no. No.cores x Outer B Weight AWG·NO.cross-sec. approx. mm w eight approx. approx. mm approx.mm• kg / km kg / km kg 1 km26001 3 G 1,5 13.6 47,0 236.0 16 26019 510,026029 4 G 1,5 14,0 58,0 274,0 16 26030 635,026002 5 G 1,5 14,5 81,0 316.0 16 26020 650.026003 7 G 1,5 18,8 115.0 440.0 16 26031 800.026004 12 G 1.5 21 ,0 196,0 606.0 16 26021 1010,026005 16 G 1,5 24,5 259,0 696,0 16 26022 1200,026006 18 G 1.5 25.5 271,0 750.0 16 26023 1300.026007 24 G 1,5 27,5 390,0 1150,0 16 26032 1700,026008 30 G 1,5 29.5 432,0 1325.0 16 26024 2000.026009 3 G 2,5 15,3 74,0 305.0 14 26025 2610.026010 4 G 2,5 16,5 98,0 350,0 14 26026 3500.026011 5G2,5 17,5 124,0 465,0 14 26027 4600,026012 7 G 2,5 20,0 168,0 576,0 14 26028 6100,026013 12 G 2.5 23,5 308,0 850.0 1426014 18 G 2.5 28.0 451.0 1181.0 1426015 24 G 2,5 32,5 615.0 1550.0 1426016 30 G 2,5 34,0 770,0 1810.0 1426017 40 G 2.5 42,5 1080,0 3110.0 1426018 50 G 2,5 46,5 1200.0 3200,0 14Dimensions and specifications may be changed without prior notice. (RG01CHELUKABEL


~HI-TECH~ CONTROLS, INC.lN)SHTOU-V<strong>Trailing</strong>-Cable(800) 677·8942 I (303) 680·5159Click or Call for a Quotelwww. h itech controls .com-(N)SHTOU -V ((Technical data• Special trailing cable according to DIN VDE0250, Part 814• Temperature rangeFlexing -25 oc to +80 oc• Max. temperature at the conductorduring operation +90 ocon short-circuit +250 oc• Nominal voltageUo/U 0,6/1 kV• Maximum permitted operating voltagesin three-phase and one-phase alternatingcurrent installationsUo/U 0,7/1,2 kVDirect current installationsUo/U 0,9/1,8 kV• Test voltage 4 kV• Insulation resistancemin. 10 MOhm x km• Minimum bending radius7,5x cable 0ApplicationCable structure• Tinned copper conductor, fine wirestranded according to DIN VDE 0295 cl. 5,BS 6360 cl. 5 or IEC 60228 cl. 5• Insulating sleeve from special rubbercompound 3GI3 in accordance with DINVDE 207 Part 20• Core identification in accordance with DINVDE 0293 Part 308 • Depending on dimension/structure withKevlar fillers• Inner sheath: Special rubber,compound-type SGMS• Torsion protection between inner andouter sheath• Outer sheath from special rubbercompound, compound type 5GM5according to DIN VDE 0207 Part 21• Sheath colour - yellowProperties• Permitted running speed up 180m/min• Fire behaviourTest in accordance w ith 0482-332-1-2. DINEN 60332-1-2/ IEC 60332-1 Part no. No.cores x Outer l1i AWC·NO. Part no. No.cores x Outer" Cop. Weight Tensile AWC·NO.cross·sec. min. · max. w eight approx. stra inmm• mm kg / km kg /km max. N31078 49 G 1 31.0. 34.5 470.0 1420.0 345031079 7 G 1.5 14.6 · 16,9 115,0 320.0 231831080 12 G 1.5 20.6. 23.4 196.0 620.0 254031081 18 c 1.5 20,3. 22,9 271.0 650.0 281031082 24 G 1.5 24.2. 27,4 390.0 930.0 308031083 30G 1.5 27,7 . 31,1 432,0 1190.0 335031084 36 1.5 27.9. 31.3 518.0 1240.0 362031085 44 c 1,5 31,2. 34,8 634.0 1530.0 398031086 48 G 1.5 31.8 . 35.4 691.0 1610.0 416031087 56 c 1,5 35.9-39,7 807.0 2020.0 452031088 7G2,5 17.5. 19,8 168.0 480.0 252031089 12 2.5 23.8. 26,7 308.0 915.0 290031090 18 c 2.5 23.4. 26.2 451.0 945,0 335031091 24 G 2.5 28,2. 31.1 615.0 1330.0 380031092 30G 2.5 31,1 . 34.4 770.0 1615,0 425031093 36 c 2,5 31.3. 34,7 866,0 1710.0 468031094 44 G 2 .5 36.2 . 40.2 1057,0 2240.0 525031095 48 G 2.5 37.2-41.0 1153,0 2410.0 555031096 56 c 2.5 41.6. 46.0 1344.0 2930.0 6150Dimensions and specifications may be changed without prior notice.


~HI-TECH~ CONTROLS, INC.(800) 677·8942 I (303) 680·5159Click or Call for a Quotelwww. h itech controls .comHELUSPREADER YSL TO·J spreader cable for vertical basket enterpriseIRoHSI·.• ~ HELUSPREADER YSL TO-J C E-·Technical data• Special cable line to DIN VDE 0250• Temperature rangef lexing -20 octo +60 ocf ixed installation -20 octo +60 oc• Max. operating temperatureat the conductor +90 oc• max. Short circuit temperatureat the conductor +150 oc• Nominal voltageUo/U 300/500 V• max. Tensile load 2000 N• Minimum bending radius15x cable 0• current carrying capacityto DIN VDE 0298 part 4ApplicationCable structure• Bare copper, fine or extra fine wireconductor to DIN VDE 0295 cl. 5 and 6, BS6360 cl. 5 and 6, IEC 60228 cl. 5 and 6• Special EPR-core insulation• Black cores with continuous whitenumbering to DIN VDE 0293• Green yellow earth-core• Cores laid-up in lay of length, strandingwith optimal length of twists around aKevlar element• Special polychloropren outer jacket• Jacket colour black (RAL 9005)Properties• weather resistant• uv-resistant• high abrasion resistanceNote• G = with green-yellow earth core.Delivery on request:• also as -K model, temperature range-40 oc to +80 oc• further dimensions and special designsAs Spreader cable with high mechanical stresses in vertical basket operation in dry, moist, wet environment and in open air. Please note thatat the installation the cable must be placed counterwise and free of twist into the basket.C €:: The product is conformed with the EC Low-Voltage Directive 2006/95/EG.Part no. No.cores x Outer 0 Cop. Weight Tensile AWC·NO. Part no. No.cores x outer 0 Cop. Weight Tensile AWC·NO.cross-sec. min. - max. w eight approx. strain cross-sec. min.- max. weight approx. strainmm 2 mm kg / km kg 1 km max. N mm• mm kg /km kg / km max. N40160 36 G 2.5 38.1 • 41 .0 864,0 2500.0 2000 14 40164 36 G 3.3 42.4 . 45.5 1140.0 3200.0 2000 1240161 42 G 2.5 40.8 . 43.8 1008.0 3000.0 2000 14 40165 42 G 3.3 46,6 · 49.6 1330.0 3750.0 2000 1640162 48 G 2.5 45.7 . 48.7 1152.0 3650,0 2000 14 40166 48 G 3.3 52.0 . 55.0 1521.0 4450.0 2000 1640163 54 G 2,5 47,0 · 51.0 1296,0 4100,0 2000 14 40167 54 G 3.3 56.6 . 60,0 1711,0 5000.0 2000 16Dimensions and specifications mav be changed without prior notice. C HELUKABEL


~HI-TECH~ CONTROLS, INC.(800) 677·8942 I (303) 680·5159Click or Call for a Quotelwww. h itech controls .com( N )TSCCEWOU extremely torsionally stiffi ~---:.: - - -. - - - -- - ----------------[RoHSITechnical data• Medium voltage power cable according toVDE 0250 part 813• Temperature rangeflexing -20 octo +60 ocfixed installation -20 oc to +80 oc• Nominal voltagesUo/U 3,6/6kV, 6/10 kV, 8,7/15kV, 12/20 kV• Operating voltages, max3,6/6 kV = 4,2/7,2 kV6/10 kV = 6,9/12 kV8,7/15 kV = 10.4/18 kV12/20 kV = 13,9/24 kV• Test voltages3,616 kV = 11 kV6/10 kV = 17 kV8,7/15 kV = 24 kV12/20 kV = 29 kV• Minimum bending radius15x outer diameterApplication~ - . ~~ (N)TSCGEWOU- ---- . .-.- -----· ..- . -- . -- - -- - - -Cable structure• Tinned copper conductor. fine wirestranded according to DIN VDE 0295 cl. 5,BS 6360 cl. 5 andIEC 60228 cl. 5• Inner semi-conducting layer• HEPR-insulation• Outer semi-conducting layer• Ground conductor with semi-conductivelayer• Cores concentrically stranded• Inner j acket. jacket colour red• Antitorsional protection• Outer sheath: chloroprene rubber,compound 5GM3• Jacket colour, redProperties• maximum permissible speed 200m/min isallowed when operating drums in onedirection• extremly torsion resistant• resistant against oils and fats. athmospericexposure and uv-radiationNote• Further dimensions and special designs onrequestReeling medium voltage supply train for use in high mechanical stresses, such as in in container cranes or large mobile equipment as wellas excavators in the m ining industry for days, in dry, damp, wet areas and outdoors.3,6/ GkVPart no. No.cores xcross-sec.mm>~~3;..,_x ;-,25 +-'53-..;;x~1c-;


HI· TECHCONTROLS' INC.Cable Accessories_(800) 677-8942 I (303) 680-5159Click or Call for a Quote!www.hitechcontrols.comThe expansion of our cable program roundsour wide product range outPhoto: Helukabel"'As a significant addition to the extensive catalogue of cables andconnectors, HELUKABEL® has set up a Cable Accessories Programaccording to the latest guidelines and standards.This applies to the f ollowing themes:• Cable f ixing• Cable protective sleeving• Drag and guidance chains• Isolation and Heatshrink sleeving• Termination & Connecting sleeves• Bundling, binding and fixing• Identification and Marking• Terminals & cable lugs• Tools• Circular ConnectorsC HELUKABEL

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!