20.08.2015 Views

EC axial fans for agricultural ventilation

EC axial fans for agricultural ventilation - ebm-papst

EC axial fans for agricultural ventilation - ebm-papst

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>EC</strong> <strong>axial</strong> <strong>fans</strong> “high pressure”Ø 500 - Ø Z50– Material: Carrying ring: Steel, galvanised, primed and coated in black plasticWall ring: Sheet steel, pre-galvanised, primed and coated in black plasticBlades (5): A Pressed-on round sheet steel plate; B C D E F G Insertion part made ofsheet aluminium; Both versions are coated and extrusion-coated in PP plasticsRotor: Primed and coated in blackElectronics enclosure: Die-cast aluminium, coated in black– Direction of rotation: A clockwise, B C D E F G counter-clockwise seen on rotor– Type of protection: IP 54 (acc. to EN 60529)– Insulation class: A "B" ("F" applying to the main components as per EN), B C D E F G "F"– Mounting position: Shaft horizontal or rotor on top– Condensate discharges: Stator-side– Mode of operation: Continuous operation (S1)– Bearings: Maintenance-free ball bearingsNominal dataBlade angleCurveNominalvoltage rangeFrequencySpeed/rpm (1)Max.Input power (1)Max.Current draw (1)Max. back pressurePerm. amb. temp.Mass withoutattachmentsTechnical features andelectr. connectionsTypeMotorVAC Hz rpm kW A Pa °C kg*3G 500 M3G 112-EA0° A1~ 200-277 50/60 1420 0,75 3,40 175 -25..+60 7,2 S. 27 / L3)*3G 630 M3G 150-IF 0° B 3~ 380-480 50/60 1510 3,20 5,00 290 -25..+65 24,4 S. 26 / L5)*3G 710 M3G 150-IF 0° C 3~ 380-480 50/60 1250 2,83 4,30 240 -25..+60 25,3 S. 26 / L5)*3G 800 M3G 150-GF 0° D 3~ 380-480 50/60 925 1,85 2,85 190 -25..+60 23,0 S. 26 / L5)*3G 910 M3G 150-NA 0° E 3~ 380-480 50/60 1000 2,88 4,40 190 -25..+65 30,9 S. 26 / L5)*3G 990 M3G 150-NA -5° F 3~ 380-480 50/60 960 2,58 4,00 180 -25..+70 31,2 S. 26 / L5)*3G Z50 M3G 200-LA 0° G 3~ 380-480 50/60 645 4,10 6,70 180 -25..+60 66,0 S. 26 / L5)subject to alterations(1) Nominal data in operating point with maximum load and 230 VAC or 400 VACCurvesnrpmP eWIAL W AdB(A)SFPW/(1000m 3 /h)p sf Pa300280260240220200180160140120100806040200,20,40,60,81,0in H 2 O0q V4B443 3 3 3AD4C442 2 2 221 1 1 115000 10000 15000 20000F310000 20000 30000 40000 50000E43G25000 3000021cfmm 3 /hAir per<strong>for</strong>mance measuredas per: ISO 5801,Installation category A,in ebm-papst full nozzlewithout protection againstaccidental contactSuction-side noise levels:L W A as per ISO 13347,L p A measured at 1 m distanceto fan axisThe acoustic values given areonly valid under the measurmentconditions listed andmay vary depending on theinstallation situation.With any deviation to the standardsetup, the specific valueshave to be checked and reviewedonce installed or fitted!For detailed in<strong>for</strong>mationsee page 30 ff.AAAABBBBCCCCDDDD12341234123412341420142014201420151015101510151012501250125012509259259259255496027057502484262528633200222623302621283012211370166118502,522,743,203,403,774,004,405,003,403,544,004,301,852,072,502,857977737481818185797979837272768060,672,1109,5126,6117,2129,7158,7234,489,899,8128,9173,250,763,2101,7140,216

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!