EC axial fans for agricultural ventilation

EC axial fans for agricultural ventilation - ebm-papst

EC axial fans for agricultural ventilation - ebm-papst

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Electrical connections <strong>EC</strong>L9)Technical features:• PFC (active) • RS485 MODBUS• Integrated PID controller • alarm relay• Control input 0-10 VDC / PWM • Line undervoltage / phase failure detection• Input <strong>for</strong> sensor 0-10 V or 4-20 mA • Motor current limitation• Slave output 0-10 V max. 5 mA • Electronics / motor overtemperature protection• Output 20 VDC (±25 % / -10 %) max. 50 mA • Locked-rotor protection• Output 10 VDC (+3 %) max. 10 mA • soft startKL3 KL2 KL18 9 10 11 12 13 14RS ARS BGNDAin1 U+10 VAin1 IDin1NOCOMNCPEL1NDin2Din3GNDAin2 U+20 VAin2 IAout1 2 3 4 5 6 7 1 2 3 1 2Connector Pin Connection Assignment / functionKL1 1 L1 Mains supply connection, supply voltage 1~200-277 VAC; 50/60 Hz; phaseNPE PE Earth connection, PE connectionKL2KL32123123/1045678911121314NOCOMNCRSARSBGNDAin1 UMains supply connection, supply voltage 1~200-277 VAC; 50/60 Hz; neutralStatus relay, floating status contact; option 1: close with error; option 2: close with run monitor error messageStatus relay; floating status contact; changeover contact; common connection; contact rating 250 VAC / 2 A (AC1)Status relay, floating status contact; option 1: break with error; option 2: break with error <strong>for</strong> run monitor error messageBus connection RS485; RSA; MODBUS RTUBus connection RS485; RSB; MODBUS RTUSignal ground <strong>for</strong> control interface KL3; SELVAnalogue input 1 (set value); 0-10 V; Ri= 100 kΩ; parametrisable curves; only usable as alternative to input Ain1 I+10 V Fixed voltage output 10 VDC; + 10 V ±3 %; max. 10 mA; short circuit proof; power supply <strong>for</strong> ext. devices (e.g. potentiometer)Ain1 I Analogue input 1 (set value); 4-20 mA; Ri= 100 Ω; parametrisable curves; only usable as alternative to input Ain1 UDin1 Digital input 1: enabling of electronics; enabling: open pin or applied voltage 5 to 50 VDC; disabling: bridge to GND or appliedvoltage < 0,8 VDC; reset function: triggers software reset after a level change to < 0,8 VDin2 Digital input 2: parameter set switch 1/2; according to EEPROM setting, the valid/used parameter set is selectable per BUS or per digital inputDIN2. Parameter set 1: open pin or applied voltage 5 to 50 VDC; parameter set 2: bridge to GND or applied voltage < 0,8 VDCDin3 Digital input 3: Control characteristic of the integrated controller; according to EEPROM setting, the control characteristic of the integrated controlleris normally/inversely selectable per BUS or per digital input; normal: open pin or applied voltage 5 to 50 VDC (control deviation = actualsensor value - set value) inverse: bridge to GND or applied voltage < 0,8 VDC (control deviation = set value - actual sensor value)Ain2 U Analogue input 2 (actual sensor value); 0-10 V; Ri= 100 kΩ; parametrisable curve; only usable as alternative to input Ain2 I+20 V Fixed voltage output 20 VDC; + 20 V +25/-10 %; max. 50 mA; short circuit proof; power supply <strong>for</strong> ext. devices (e.g. sensors)Ain2 I Analogue input 2 (actual sensor value); 4-20 mA; Ri= 100 Ω; parametrisable curve; only usable as alternative to input Ain2 UAout Analogue output 0-10 V; max. 5 mA; output of the actual motor control factor (output voltage of electronics)/of the actual motor speed; functionselectable per bus; parametrisable curve.28

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!