Condensing boiler technology

Condensing boiler technology [PDF] 9.1 MB - ebm-papst

Condensing boiler technology [PDF] 9.1 MB - ebm-papst

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

E01Size GB055D01Size GB057––Housing: Aluminium––Electrical connection: Connector shell with 4.20 mm grid(Stocko: STO-FIT; Wuerth: WR-MPC4 series)––Inlet (gas connection): External thread G3/4 or G1/2 (DIN EN ISO 228)or 4 x M4 mounting holes (optional)––Outlet: ebm-papst specific quick-connector––Safety valves: Coaxial design: valve class B/C in accordance with EN161––Housing: Aluminium––Electrical connection: Connector shell with 5.08 mm grid(e.g. Molex KK ® system: Art.10-01-1054)––Inlet (gas connection): 4 x M5 mounting holes (36 mm hole spacing)––Outlet: 4 x M5 mounting holes (36 mm hole spacing)––Safety valves: Valve class B/B in accordance with EN161Nominal dataRated voltageMax. input powerNominal diameterMaximum inletpressureFlow rate(at Δp = 5 mbar)Automaticshutoff valves(EN161)Minimumsignal pressureOpening andclosing timeNominal dataRated voltageMax. input powerNominal diameterMaximum inletpressureFlow rate(at Δp = 5 mbar)Automaticshutoff valves(EN161)Minimumsignal pressureOpening andclosing timeUnit V VA mbar m³/h Pa sGB-ND 055 E01 230 RAC 9.8 DN15 65 3.4 Class B/C -30 < 1120 RAC 9.8 DN15 65 3.4 Class B/C -30 < 124 RAC 8.1 DN15 65 3.4 Class B/C -30 < 1Unit V VA mbar m³/h Pa sGB-ND 057 D01 230 RAC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 1120 RAC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 124 RAC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 124 DC 2 x 12.5 DN20 65 5.3 Class B/B -30 < 1Capacity curve - GB055Capacity curve - GB05710080100806050403060recommended work work range range 50recommended work range4030∆p [mbar]201086543∆p [mbar]∆2010865432Conditions: + 15° C / 59 °F, p , = 1013 mbar2Conditions: + 15° C/59 °F, p = 1013 mbar10,1 0,2 0,3 0,4 0,5 0,6 0,8Vn ° [m 3 /h] Luft / Air (dv = 1,00)1 2 3 4 5 6 7 8 910 20servoregulatorsolenoid coilelectricalconnection10,1 0,2 0,3 0,4 0,5 0,6 0,8V ° n [m 3 /h] Luft / Air (dv = 1,00)12 3 4 5 6 7 8 9 1020servo regulatorpressure regulatoroffset adjustmentelectrical connection0,2 0,3 0,4 0,5 0,6 0,8 1 2 3 4 5 6 7 8 910 20 30Vn ° [m 3 /h] Erdgas / Natural gas (dv = 0,65)0,2 0,3 0,4 0,5 0,6 0,81 2 3 4 5 6 7 8 910V ° n [m 3 /h] Erdgas / Natural gas (dv = 0,65)20 30pressure testnipple P 1pressure testnipple P 2main flow throttlepressure testnipple P 1pressuretest nipple P 2main flow throttlesolenoid coil36 37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!