6 TroubleshootingSymptomLamp does not light, power switchdoes not light, and fans do not start.Lamp does not light, powerswitch lights, fans are running.UV Output is low,(Radiometer Reading)Poor or Slow Cure ResultsCorrective Action/Possible Cause1. Make sure the system is plugged in.2. Check the fuse in the power cord receptacle.1. Make sure that the lamp is plugged in.2. Lamp is at end of its life.3. Check that the connector cord is properly installedat both ends.1. Reflector needs to be cleaned.2. Lamp is at end of its life.3. Lamp needs to be cleaned.4. Check radiometer accuracy, calibration.1. UV output is low, (see above).2. Product is not compatible with the lamp type.3. Position lamp closer to the part.5