Material standard values<br />

Material<br />

TECADUR<br />

PBT GF30<br />

TECAMID<br />

6<br />

TECAM<br />

6 MO<br />

TECAMID<br />

6 GF25<br />

black<br />

TECAMID<br />

6 GF30<br />

black<br />

TECAMID<br />

6 ID<br />

blue<br />

TECAMID<br />

66<br />

TECAMID<br />

66 MH<br />

TECAMID<br />

66 GF30<br />

black<br />

TECAMID<br />

66/X GF50<br />

black<br />

Chemical Designation<br />

PBT PA 6 PA 6 PA 6 PA 6 PA 6 PA 66 PA 66 PA 66 PA 66<br />

Fillers<br />

glass fibres<br />

molybdenum<br />

disulfide<br />

glass fibres glass fibres detectable<br />

filler<br />

molybdenum<br />

disulfide<br />

glass fibres<br />

glass fibres<br />

Density<br />

(DIN EN ISO 1183)<br />

Mechanical properties<br />

Modulus of elasticity (tensile test)<br />

(DIN EN ISO 527-2)<br />

Tensile strength<br />

(DIN EN ISO 527-2)<br />

Tensile strength at yield<br />

(DIN EN ISO 527-2)<br />

Elongation at yield<br />

(DIN EN ISO 527-2)<br />

Elongation at break<br />

(DIN EN ISO 527-2)<br />

Modulus of elasticity (flexural test)<br />

(DIN EN ISO 178)<br />

Flexural strength<br />

(DIN EN ISO 178)<br />

Compression modulus<br />

(EN ISO 604)<br />

Compressive strength (1% / 2 %)<br />

(EN ISO 604)<br />

Impact strength (Charpy)<br />

(DIN EN ISO 179-1eU)<br />

Notched impact strength (Charpy)<br />

(DIN EN ISO 179-1eA)<br />

Ball intendation hardness<br />

(ISO 2039-1)<br />

Thermal properties<br />

Glass transition temperature<br />

(DIN 53765)<br />

Melting temperature<br />

(DIN 53765)<br />

Service temperature,<br />

short term<br />

Service temperature,<br />

long term<br />

Thermal expansion (CLTE),<br />

23 – 60 °C (DIN EN ISO 11359-1;2)<br />

Thermal expansion (CLTE),<br />

23 – 100 °C (DIN EN ISO 11359-1;2)<br />

Specific heat<br />

(ISO 22007-4:2008)<br />

Thermal conductivity<br />

(ISO 22007-4:2008)<br />

Electrical properties<br />

Specific surface resistance<br />

(DIN IEC 60093)<br />

Surface resistance<br />

(DIN IEC 60093)<br />

Miscellaneous data<br />

Water absorption 24 h / 96 h (23 °C)<br />

(DIN EN ISO 62)<br />

Resistance<br />

to hot water / bases<br />

Resistance to weathering<br />

Flammability (UL94)<br />

(DIN IEC 60695-11-10;)<br />

[ g / cm³ ]<br />

[ MPa ]<br />

[ MPa ]<br />

[ MPa ]<br />

[%]<br />

[%]<br />

[ MPa ]<br />

[ MPa ]<br />

[ MPa ]<br />

[ MPa ]<br />

[ kJ / m² ]<br />

[ kJ / m² ]<br />

[ MPa ]<br />

[ °C ]<br />

[ °C ]<br />

[ °C ]<br />

[ °C ]<br />

[ 10 -5 K -1 ]<br />

[ 10 -5 K -1 ]<br />

[ J / (g*K)]<br />

[ W /(m*K)]<br />

[ Ω ]<br />

[ Ω*cm ]<br />

[%]<br />

1.46 1.14 1.14 1.33 1.36 1.24 1.15 1.15 1.34 1.61<br />

3,400 3,300 3,300 5,100 5,700 3,600 3,500 3,200 5,500 8,700<br />

46 79 84 96 98 80 85 84 91 115<br />

46 78 82 96 98 80 84 83 91 115<br />

5 4 5 9 4 4 7 10 8 2<br />

6 130 37 11 5 21 70 40 14 2<br />

3,400 2,900 3,100 4,900 5,200 3,100 3,100 4,700 9,000<br />

78 100 110 143 140 110 114 135 200<br />

2,800 2,700 2,900 3,900 4,200 2,700 2,700 4,100 6,200<br />

20 / 38 24 / 41 17 / 32 21 / 42 21 / 42 20 / 35 20 / 38 25 / 46 28 / 56<br />

37.0 n. b. n. b. 78.0 60.0 n. b. n. b. n. b. 97.0<br />

7.0 5.0 4.0 5.0 5.0<br />

190 155 160 230 232 175 168 216<br />

45 51 49 49 45 47 52 48 78<br />

224 221 220 217 218 220 258 253 254 256<br />

200 160 160 180 180 160 170 170 170 200<br />

110 100 100 100 100 100 100 100 110 130<br />

8 12 8 7 6 11 10 5<br />

10 13 8 8 6 12 10 5<br />

1.2 1.6 1.6 1.4 1.3 1.5 1.5 1.2<br />

0.33 0.37 0.37 0.40 0.41 0.36 0.36 0.39<br />

10 14 10 14 10 14 10 14 10 14 10 13 10 14 10 14 10 14 10 14<br />

10 14 10 14 10 14 10 14 10 14 10 14 10 14 10 14<br />

0.02 / 0.04 0.3 / 0.6 0.3 / 0.6 0.2 / 0.3 0.2 / 0.3 0.3 / 0.6 0.2 / 0.4 0.2 / 0.4 0.1 / 0.2 0.1 / 0.2<br />

- (+) (+) (+) (+) (+) (+) (+) (+) -<br />

- - (+) (+) (+) - - (+) (+) (+)<br />

HB e HB e HB e HB e HB e HB e HB e HB e HB e HB<br />

Appendix<br />

Data generated directly after machining (standard<br />

climate Germany). For polyamides the values strongly<br />

depend on the humidity content.<br />

Test specimen to DIN EN ISO 527-2<br />

+ good resistance<br />

(+) limited resistance<br />

– poor resistance (depending on concen -<br />

tration, time and temperature)<br />

n.b. not broken<br />

n.a. not applicable<br />

(a) Glass transition temperature<br />

testing according to DIN EN ISO 11357<br />

(b) Thermal conductivity testing according to ISO 8302<br />

(c) Thermal conductivity testing according to ASTM E1530<br />

(d) Surface resistance testing according to ASTM D 257<br />

(e) No listing at UL (yellow card). The information might be<br />

taken from resin, stock shape or estimation. Individual<br />

testing regarding application conditions is mandatory.<br />

(f) Thermal expansion (CLTE), 50 – 200 °C<br />

98