fasis - Wieland

fasis - Wieland

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>selos</strong> BIT<br />

Busbar<br />

Accumulating and isolating the neutral potential<br />

• Combining the neutral conductors of the individual circuits<br />

through the neutral busbar up to a current load of 140 A.<br />

• Connection of the busbar’s neutral potential to the<br />

ground-fault circuit interrupter or supply for the distribution<br />

unit with connector clamp WAK in 16 or 35 mm 2 .<br />

• Safe and stable 3D positioning of the<br />

neutral busbar through busbar support with end clamping<br />

function.<br />

Cross connectors<br />

Jumpering the terminal blocks<br />

• Choice between insulated and uninsulated cross connectors.<br />

• Touch-proof insulated cross connectors according to IP 20<br />

without additional actions.<br />

• Uninsulated cross connectors require covers to make them<br />

touch-proof.<br />

• Jumper bars as additional jumpering option are inserted into<br />

the clamping body together with the conductor.<br />

Cover<br />

Partition plates<br />

Marking live potentials<br />

• Marking of live components for greater safety.<br />

• For terminal blocks that remain live when the main switch is<br />

disconnected (DIN VDE 0113).<br />

• The snap-on cover can only be removed with a tool.<br />

Potential isolation<br />

• Rated voltage can be applied to adjacent uninsulated cross<br />

connectors.<br />

• Can be mounted later on without loss due to separation<br />

• The snap-on partition plate can only be removed with a tool.<br />

Marking system<br />

Clearly mark all clamping points<br />

• Marking tags easily readable even with the wires connected.<br />

• Clear assignment of wire to termination point on wiring.<br />

• Simplified troubleshooting for maintenance.<br />

• Individual marking with the wiemarc and wieplot<br />

marking system.<br />

Material<br />

Selection of high-quality materials<br />

• Special alloys en able low contact resistance and provide<br />

a gas-tight contact area:<br />

– Clamping spring: steel, zinc-plated and dichromated<br />

– Busbar: tin-plated copper<br />

• Polyamide has excellent electrical, chemical and<br />

mechanical characteristics:<br />

– Temperature resistance: up to 120 °C<br />

– Creepage resistance: CTI 600<br />

– Flammability class: self-extinguishing, UL94-V0<br />