Marley Leafslide Series 3
Installation Guide - Marley New Zealand
Installation Guide - Marley New Zealand
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Marley</strong> <strong>Leafslide</strong> <strong>Series</strong> 3<br />
- Enhanced performance & improved aesthetic design<br />
Fine stainless<br />
steel mesh<br />
Easy to install • Low maintenance • Allows for clean water collection<br />
• Retains over 95% of water • Mosquito proof • Fits all <strong>Marley</strong> downpipes.<br />
Rainwater Solutions
The <strong>Marley</strong> <strong>Leafslide</strong> series 3 works as a debris diverter and water filter for new or existing<br />
downpipes. It helps to stop leaves, animal droppings, mosquitoes and other debris from<br />
entering into your tank or stormwater. The <strong>Leafslide</strong> is manufactured from UV stabilised<br />
PVC with a fine stainless steel mesh screen ensuring over 95% of water is captured.<br />
<strong>Leafslide</strong>s are easy to install and require minimal maintenance. Code: RWLS<br />
Positioning – The Leaflside is designed to be used with <strong>Marley</strong> 80mm & 65mm Round Downpipe,<br />
Eclipse Half-Round Downpipe and Rectangular (65mm x 50mm and 100mm x 50mm) Downpipe. When<br />
installing a <strong>Leafslide</strong> in a wet system ensure it is installed above the maximum level of the water tank.<br />
• If the <strong>Leafslide</strong> is being connected to a tank, the tank must be at least 300mm lower<br />
than the spouting (fig 1) and the <strong>Leafslide</strong> must be above the inlet to the tank.<br />
• Less splashing is observed when a vertical drop of the downpipe running into the<br />
<strong>Leafslide</strong> is 1.5 metres or less.<br />
• The downpipe should be mounted flush with the back wall of the <strong>Leafslide</strong> body.<br />
• Consideration should always be given as to where debris is discharged, eg. pathways<br />
and decks.<br />
Installation<br />
To install the <strong>Leafslide</strong>, you will need<br />
– Screwdriver and screws<br />
– Downpipe adaptors (RA65.80, HR80.BA, MC19.80 and MC141.80)<br />
– <strong>Marley</strong> MCS solvent cement<br />
– Hacksaw<br />
– Ladder<br />
1. Position the downpipe into the top of the <strong>Leafslide</strong> body, so there is at least<br />
10-15mm of downpipe inside the <strong>Leafslide</strong> inlet. The further into the <strong>Leafslide</strong> the<br />
downpipe sits the better, making sure not to wedge the downpipe against the<br />
screen making it difficult to take out and clean.<br />
2. Screw the <strong>Leafslide</strong> to the wall or fascia using the screw holes at the back of the<br />
<strong>Leafslide</strong> body. The <strong>Leafslide</strong> may need spacers between the wall and the <strong>Leafslide</strong><br />
depending on the type of wall and downpipe brackets.<br />
RWLS. SCREEN<br />
3. The outlet of the <strong>Leafslide</strong> can be connected to 80mm downpipe using <strong>Marley</strong><br />
Solvent Cement (MCS), follow the <strong>Marley</strong> Solvent Cement Instructions in the<br />
Rainwater Installation Guide available at www.marley.co.nz. Use an adapter to<br />
connect to other size downpipes.<br />
Maintenance – Routinely wash the filter screen, by lifting it out of the body and cleaning it.<br />
For an optimum performance of your leafslide, check regularly that there is no debris on the screen<br />
blocking the flow.<br />
Product Guarantee - Screen: 5 years when adequately maintained. Body: 15 years.<br />
Additional screens are available separately.<br />
DISCLAIMER<br />
This technical catalogue has been compiled by <strong>Marley</strong> New Zealand Limited (“The Company”) to promote better understanding<br />
of the technical aspects of the Company’s products to assist users in obtaining from them the best possible performance.<br />
The technical catalogue is supplied subject to acknowledgment of the following conditions:<br />
The technical catalogue is protected by Copyright and may not be copied or reproduced in any form or by any means in whole<br />
or in part without prior consent in writing by the Company.<br />
Product specifications, usage data and advisory information may change from time to time with advances in research and field<br />
experience.<br />
The Company reserves the right to make such changes at any time without notice.<br />
Correct usage of the Company’s products involve engineering judgements which cannot be properly made without full knowledge<br />
of all the conditions pertaining to each specific installation. The Company expressly disclaims all and any liability to any person<br />
whether supplied with this publication or not in respect of anything and of the consequences of anything done or omitted to be<br />
done by any such person in reliance whether whole or partial upon the whole or any part of the contents of this publication.<br />
No offer to trade, nor any conditions of trading, are expressed or implied by the issue or content of this manual.<br />
Nothing herein shall override the Company’s Conditions of Sale, which may be obtained from the Registered Office or any Sales<br />
Office of the Company.<br />
This technical catalogue is and shall remain the property of the Company, and shall be surrendered on demand to the Company.<br />
AUCKLAND - Mahia Road, Manurewa,<br />
Private Bag 802, Manurewa.<br />
Sales Department Tel: 09 279 2777<br />
Direct Fax: 09 279 2778<br />
Freefax: 0800 652 621<br />
Head Office Tel: 09 279 2799<br />
Fax: 09 279 2798<br />
CONTACT CENTRE: 0800 222 922<br />
CHRISTCHURCH<br />
Shands Road, Hornby,<br />
PO Box 16233 Christchurch.<br />
CONTACT CENTRE: 0800 222 922<br />
Energi 200402<br />
For more information: 0800 MARLEY (0800 627 539)<br />
Rainwater Solutions