12.09.2015 Views

technical

56 & 66 Series Industrial Switchgear International Technical Data ...

56 & 66 Series Industrial Switchgear International Technical Data ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Catalogue Switching I the<br />

U i<br />

/ U e<br />

I e<br />

(A) Utilisation Category M Battery Running Minimum Conductor Term. IP O/A* Dims.<br />

Number (A) (V) Rating Reserve Switch Time size in mm 2 Rating (H) x (W) x (D)<br />

AC21A AC22A AC23A (Hrs) Min. Max.<br />

56TCDB 1 C/O 10A 250 10 10 8 100 **150 hours 1min 2.5 6 66 107x101x100<br />

I the<br />

- Conventional Enclosed Thermal<br />

Current<br />

U I<br />

- Insulated Voltage<br />

U e<br />

- Operational Voltage<br />

I e<br />

- Operational Current<br />

** Nicad rechargeable battery takes 70<br />

hours to fully charge.<br />

* Refer rear of Catalogue for further<br />

details.<br />

56SWT216 Two Hour<br />

Process Timer<br />

Clipsal’s 56 Series Two Hour<br />

Process Timer is a surface mounting<br />

model that features a mechanical timer<br />

operated by a rotary switch.<br />

The timer is fully variable with the<br />

range of zero to two hours in ten minute<br />

increments which can be reset or<br />

overridden at any stage.<br />

A single gang module, the unit is<br />

double pole 250V 16A a.c. and is supplied<br />

as standard with a power on neon.<br />

The 16A mechanism has pressure<br />

plate type terminals. The 56SWT216<br />

is ideally suited to run pumping or filtering<br />

operations or for use with hot water<br />

service boosters. Also suitable for<br />

fluorescent loads.<br />

Earth and neutral connectors<br />

accommodating 3 x 6mm 2 cables are<br />

supplied.<br />

Option available<br />

•<br />

Less enclosure - add LE to<br />

Catalogue Number e.g. 56SWT216<br />

becomes 56SWT216LE.<br />

56SWT216<br />

Catalogue Switching I the<br />

U i<br />

/ U e<br />

I e<br />

(A) Utilisation Category M Switching Conductor Term. IP O/A* Dims.<br />

Number (A) (V) Rating Time size in mm 2 Rating (H) x (W) X (D)<br />

AC21A AC22A AC23A Min. Max.<br />

26<br />

56SWT216 2 Pole 16 250 16 10 10 120 10 mins. 2.5 4 56 107x101x100<br />

Minimum<br />

120 mins.<br />

Maximum<br />

I the<br />

- Conventional Enclosed Thermal Current<br />

U I<br />

- Insulated Voltage<br />

U e<br />

- Operational Voltage<br />

I e<br />

- Operational Current<br />

Note: AC utilisation categories to AS 3947.3.<br />

Refer to rear of catalogue for further details.<br />

*

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!