26.09.2015 Views

Technical data/accesories Rotary Microtome HM 325 Standard in microtomy

Technical data/accesories Rotary Microtome HM 325 Standard in ...

Technical data/accesories Rotary Microtome HM 325 Standard in ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Technical</strong> <strong>data</strong>/<strong>accesories</strong> <strong>Rotary</strong> <strong>Microtome</strong> <strong>HM</strong> <strong>325</strong><br />

<strong>Technical</strong> features <strong>HM</strong> <strong>325</strong><br />

– Ergonomic design<br />

– Compact dimensions<br />

– Mechanical precision feed mechanism<br />

– Especially smooth runn<strong>in</strong>g handwheel<br />

– One-hand quick clamp change<br />

– Easy exchange of specimens<br />

– Specimen orientation universal 8°,<br />

rotatable 360°<br />

– Specimen retraction dur<strong>in</strong>g return travel, can<br />

be turned off two mechanical trim stages<br />

(10 µm/30 µm)<br />

– Electronic section counter, resettable<br />

– Precision micrometer mechanism with enclosed<br />

hous<strong>in</strong>g<br />

– Section thickness range: 0,5 µm up to 60 µm<br />

from 0 … 2 µm <strong>in</strong> 0,5 µm- <strong>in</strong>crements<br />

from 2 …10 µm <strong>in</strong> 1 µm- <strong>in</strong>crements<br />

from 10…20 µm <strong>in</strong> 2 µm- <strong>in</strong>crements<br />

from 20…60 µm <strong>in</strong> 5 µm- <strong>in</strong>crements<br />

– Section thickness <strong>in</strong>dication <strong>in</strong> <strong>in</strong>dex w<strong>in</strong>dow<br />

– Manual coarse feed via coarse wheel<br />

– Horizontal overall specimen feed 28 mm<br />

– Vertical specimen stroke 64 mm<br />

– F<strong>in</strong>e orientation with one-hand operation and<br />

zero-position<strong>in</strong>g<br />

– Spacious section waste tray, cover<strong>in</strong>g the entire<br />

work<strong>in</strong>g area<br />

– Ergonomically optimized operat<strong>in</strong>g elements<br />

for non-tir<strong>in</strong>g usage<br />

– Design with highest demands to<br />

Operational safety and ergonomics<br />

– Integrated removable storage plate<br />

A wide range of special<br />

accessories adaptable<br />

– STS (Section Transfer System)<br />

– Cool Cut<br />

– Microscope<br />

– Large field magnifier<br />

– Clamp<strong>in</strong>g devices<br />

Dimensions:<br />

Wide: 420 mm Depth: 490 mm Height: 280 mm<br />

Weight: 23 kg<br />

Certificates: CE<br />

Knife carrier systems<br />

Disposable blade carrier E<br />

Clamp<strong>in</strong>g plate that can be moved aside for<br />

easy position<strong>in</strong>g of the blade. For high and low<br />

profile blades.<br />

Disposable blade carrier ER<br />

The blade can be moved aside without open<strong>in</strong>g<br />

the blade clamp<strong>in</strong>g. For high and low profile<br />

blades.<br />

<strong>Standard</strong> knife carrier N<br />

For conventional knives, tungsten carbide knives<br />

and disposable blade holders with knife height<br />

adjustment.<br />

<strong>Standard</strong> knife carrier C<br />

With central clamp<strong>in</strong>g plate for highest stability.<br />

Disposable blades SEC 35<br />

Of high-quality steel and coated with a newly<br />

developed, unique layer allow<strong>in</strong>g best cutt<strong>in</strong>g<br />

results with longevity of the knife.<br />

MICROM International GmbH<br />

Robert-Bosch-Strasse 49<br />

D-69190 Walldorf<br />

Phone: +49-6227-836 0<br />

Fax: +49-6227-836 111<br />

e-mail: <strong>in</strong>fo@microm.de<br />

Internet: www.microm.de<br />

Rev. 01 06<br />

<strong>Standard</strong><br />

<strong>in</strong> <strong>microtomy</strong>.


MICROM <strong>HM</strong> <strong>325</strong> – Multi-purpose microtome for rout<strong>in</strong>e and research<br />

Innovation <strong>in</strong> tradition<br />

MICROM is an <strong>in</strong>novative technology<br />

company and world's lead<strong>in</strong>g microtome<br />

manufacturer.<br />

The experience MICROM specialists ga<strong>in</strong>ed<br />

over decades <strong>in</strong> close relationship with<br />

scientists throughout the world comb<strong>in</strong>ed<br />

with our cont<strong>in</strong>uous effort to achieve better<br />

eng<strong>in</strong>eer<strong>in</strong>g solutions result <strong>in</strong> the<br />

development of products of utmost<br />

reliability, user benefit and outstand<strong>in</strong>g<br />

operator comfort. For decades Microm has<br />

def<strong>in</strong>ed the standard <strong>in</strong> operational safety<br />

and ergonomics <strong>in</strong> <strong>microtomy</strong> and cryo<br />

<strong>microtomy</strong>.<br />

MICROM stands for:<br />

• Highest operator safety<br />

• Ergonomic design<br />

• Trend sett<strong>in</strong>g <strong>in</strong>novative technology<br />

• High quality standards<br />

• Excellent price/performance ratio<br />

• User-oriented design with an optimum<br />

of operator comfort<br />

Precision micrometer<br />

mechanism<br />

The unique section thickness sett<strong>in</strong>g<br />

allows operation with both the left and<br />

the right hand. The removable sett<strong>in</strong>g<br />

knobs can be operated on the right<br />

and left side of the <strong>in</strong>strument<br />

result<strong>in</strong>g <strong>in</strong> an <strong>in</strong>dividual operation<br />

without surpass<strong>in</strong>g, even while<br />

section<strong>in</strong>g. The section thickness range<br />

can be selected between 0,5 µm and<br />

60 µm and is constantly monitored on<br />

the <strong>in</strong>dex w<strong>in</strong>dow on the front side of<br />

the <strong>in</strong>strument.<br />

Zero-backlash vertical<br />

specimen movement<br />

The use of highest precision for the vertical<br />

specimen movement comb<strong>in</strong>es unmatched<br />

smooth runn<strong>in</strong>g with highest stability for<br />

outstand<strong>in</strong>g section quality, even with high<br />

cutt<strong>in</strong>g forces.<br />

Specimen retraction dur<strong>in</strong>g<br />

return travel<br />

The feature specimen retraction <strong>in</strong> this<br />

class provided the basis for the lead<strong>in</strong>g<br />

position of this microtome.<br />

The advantages are an <strong>in</strong>creased section<br />

quality, trouble-free ribbonn<strong>in</strong>g of sections<br />

and an extended lifetime of the section<strong>in</strong>g<br />

tools.<br />

Coarse feed device and<br />

trim function<br />

zone two trim stages are applicable<br />

(10 µm und 30 µm) <strong>in</strong>dependent from the<br />

preset f<strong>in</strong>e section thickness.<br />

Specimen f<strong>in</strong>e orientation<br />

with quick change function<br />

- The specimen f<strong>in</strong>e orientation allows a<br />

precise alignment of the specimen <strong>in</strong><br />

horizontal (X-) and vertical (Y-) direction<br />

with Zero-position<strong>in</strong>g.<br />

- Equipped with a snap-<strong>in</strong> function, the<br />

parallel alignment towards the cutt<strong>in</strong>g<br />

surface is easy and fast.<br />

- The operat<strong>in</strong>g knobs on the left side allow<br />

an ergonomic one-hand operation<br />

result<strong>in</strong>g <strong>in</strong> an easy accessibility,<br />

even when us<strong>in</strong>g large clamps or<br />

a Cool-Cut.<br />

- All clamp<strong>in</strong>g devices can be easily<br />

and fast replaced by loosen<strong>in</strong>g one<br />

lever only.<br />

- The especially flat design guarantees<br />

favourable leverages to avoid artifacts,<br />

especially when high cutt<strong>in</strong>g forces are<br />

applied.<br />

Electronic section counter<br />

The electronic section counter, which can<br />

be reset, allows count<strong>in</strong>g of work processes<br />

and supports your lab operation.<br />

Handwheel brake<br />

The handwheel can be locked <strong>in</strong> any<br />

position and guarantees a safe specimen<br />

exchange.<br />

The reduced number of levers cannot be<br />

mixed up dur<strong>in</strong>g operation and is usable<br />

without any tools. The levers be<strong>in</strong>g partly<br />

adjustable and usable from right and left<br />

side simplify appliance with <strong>in</strong>creased<br />

operator safety. The knife carrier system<br />

offers an <strong>in</strong>dividual configuration for each<br />

application. With the horizontal precision<br />

guidance standard knives, tungsten carbide<br />

knives, and disposable blades (low and<br />

high profile) can be used. All knife holders<br />

are equipped with a f<strong>in</strong>ger guard.<br />

Ergonomic design with<br />

unique section waste tray<br />

The outstand<strong>in</strong>g ergonomics <strong>in</strong> the<br />

daily rout<strong>in</strong>e is shown <strong>in</strong> the patented wellshaped<br />

knife carrier <strong>in</strong>sertion. The entire<br />

work<strong>in</strong>g area both beh<strong>in</strong>d as well as below<br />

the knife carrier is covered by a large<br />

removable section waste tray, which is very<br />

easy and fast to clean. The front area of<br />

the section waste tray is designed as an<br />

arm rest. This practice-oriented design is<br />

an exclusive feature of MICROM<br />

<strong>Rotary</strong> <strong>Microtome</strong> <strong>HM</strong> <strong>325</strong><br />

The <strong>Rotary</strong> <strong>Microtome</strong> <strong>HM</strong> <strong>325</strong> sets new<br />

standards <strong>in</strong> the rout<strong>in</strong>e microtome class.<br />

A high section stability and precision<br />

make this <strong>in</strong>strument a universal multipurpose<br />

microtome for highest demands<br />

both for paraff<strong>in</strong> section<strong>in</strong>g technique as<br />

well as for manual hard section<strong>in</strong>g<br />

technique <strong>in</strong> biology, medic<strong>in</strong>e and<br />

<strong>in</strong>dustry.<br />

The sense of rotation for activat<strong>in</strong>g<br />

the coarse feed is identical<br />

with the sense of the cutt<strong>in</strong>g<br />

movement. This ensures an<br />

precise approach of the specimen<br />

towards the knife. For<br />

approach towards the cutt<strong>in</strong>g<br />

Knife carrier system<br />

The knife carrier system comb<strong>in</strong>es outstand<strong>in</strong>g<br />

stability with unsurpassed ergonomics.<br />

*Accessories not <strong>in</strong>cluded.