KROHNE 03/2008 <strong>KPM</strong><br />

<strong>PADDLE</strong> <strong>FLOWMETER</strong><br />

<strong>KPM</strong><br />

Paddle flowmeters<br />

Variable area flowmeters<br />

Flow controllers<br />

Electromagnetic flowmeters<br />

Level measuring instruments<br />

Communications technology<br />

Engineering system & solutionns<br />

Temp meters<br />

Pressure meters


Measuring principle<br />

If a medium flows with sufficient velocity through the horizontally<br />

or vertically arranged measuring chamber. If the <strong>KPM</strong> fitting, the<br />

paddle will swivel around the axie until the force of the medium<br />

and the opposing force of the paddle surface plus the spring<br />

tension establish equilibrium. The angular position or the position<br />

of equilibrium of the paddle in the measuring chamber is the<br />

measure for the flow. The encapsulated ring-type permanent<br />

magnet at the end of the paddle axis then transmits this position<br />

to the scale and the optional electronic evaluators through the<br />

magnet tracking indicator system.This happens safely and without<br />

packing glands. The flow rates shown on the scale only apply to<br />

the calibrated medium or to a medium with the same physical<br />

characteristics.<br />

Introduction<br />

<strong>KPM</strong> flowmeter is suitable for measurement of liquid in pipes.<br />

The special advantage is that it can be used for all directions<br />

2. Paddle 3. Paddle axis with torsion spring<br />

4. Pointer<br />

of flow. It can show the current flow rate in volume or mass per<br />

unit in time.<br />

Applications: flow measurement, dosing, monitoring, adjusting<br />

and control of liquid products. The meter’s design makes it<br />

ideal for processes under difficult and adverse operating<br />

conditions.<br />

1. Fitting<br />

The devices are available with additional electrical equipment<br />

for process monitoring and control.<br />

6. Scale panel<br />

Approvals:<br />

• ISO9001<br />

• ERP Pass Financial Certificates<br />

• Membership of the Sinopec Resource Market<br />

• Membership of the first order supplying the network of the<br />

PetroChina<br />

• CMC:JIZHI 08000115


Features:<br />

• Tube Size:DN50-DN300;Pressure Rating :PN10-PN40;Temp:< 200℃<br />

• Measurement of the liquid<br />

• Liquid waste<br />

• All directions of flow<br />

• Reliable Capability, Steady Measure<br />

• Output:Current Signal、Local Display 、HART,PROFIBUS<br />

• Corrosive Fields and Volatile Fields<br />

• Ex“ia”<br />

Main technical Parameters<br />

Type<br />

<strong>KPM</strong><br />

Messuring ranage(100%) 水 :20℃ 2-600m 3 /h<br />

Accuracy 2.5<br />

Scale<br />

Meter Size<br />

Actually flow<br />

DN50-DN300<br />

PN40(DN50-DN80)<br />

Pressure class<br />

PN16(DN100-DN200)<br />

PN10(DN250-DN300)<br />

Connect flange size<br />

DN50-DN300<br />

Fluid Temp - 20℃ ~+200 ℃<br />

Ambient Temp<br />

With switches<br />

With signal output<br />

- 20℃ ~+80℃<br />

Power : 8V DC<br />

Ambient Temp: -20℃~+60℃<br />

Analog Signals : 4-20mA(2-wires)<br />

Power: 24VDC±10~20%<br />

Ambient Temp: -20℃~+60℃


Model instructions<br />

<strong>KPM</strong> Series :<br />

∕□ ∕□ ∕□ ∕□ ∕□ ∕□ ∕□ ∕□<br />

1 2 3 4 5 6 7 8<br />

1 05S DN50 SANDWICH 05F DN50 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

08S DN80 SANDWICH 08F DN80 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

10S DN100 SANDWICH 10F DN100 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

12S DN125 SANDWICH 12F DN125 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

15S DN150 SANDWICH 15F DN150 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

20S DN200 SANDWICH 20F DN200 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

25S DN250 SANDWICH 25F DN250 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

30S DN300 SANDWICH 30F DN300 FLANGE F-STNDARD: DIN2501,HG,GB,ANSI. ETC<br />

2 U Vertically top to bottom<br />

D Vertically bottom to top<br />

R Horizontally right to left<br />

L Horizontally left to right<br />

3 RR1 304 , 1Cr18Ni9Ti<br />

RR0 316Ti , 0Cr17Ni12MoTi<br />

RRL 316l , 00Cr17Ni14Mo2<br />

4 M81 M81 Aluminum indicator with local flow value<br />

M9 M9 Aluminum indicator with local flow value<br />

5 00 No Switches (Default)<br />

K1 With one 2-wires Switch<br />

K2 With two 2-wires Switch<br />

KD1 With one 3-wires Switch<br />

KD2 With two 3-wires Switch<br />

6 00 No Signal Putput (Default)<br />

ESK 4-20mA (M9)<br />

ESKZ 4-20mA Totalizer (M9)<br />

Es 4-20mA (M81)<br />

7 00 Non Ex (Default)<br />

Exi ExiaIICT3-T6<br />

Exd ExdIIbT3-T6<br />

8 HT For medium temp>100 ℃


Measuring range table<br />

Nominal<br />

size(DN)<br />

50<br />

80<br />

100<br />

125<br />

150<br />

200<br />

250<br />

300<br />

Measuring<br />

range code<br />

Measuring range----- Water 1000Kg/m 3<br />

5.1 2-10 m 3 /h<br />

5.2 5-30 m 3 /h<br />

8.1 4-25 m 3 /h<br />

8.2 6-50 m 3 /h<br />

8.3 8-70 m 3 /h<br />

10.1 6-45 m 3 /h<br />

10.2 10-80 m 3 /h<br />

10.3 15-100 m 3 /h<br />

12.1 15-100 m 3 /h<br />

12.2 20-125 m 3 /h<br />

15.1 20-150 m 3 /h<br />

15.2 25-200 m 3 /h<br />

20.1 25-200 m 3 /h<br />

20.2 40-300 m 3 /h<br />

20.3 60-450 m 3 /h<br />

25.1 40-300 m 3 /h<br />

25.2 70-400 m 3 /h<br />

25.3 80-500 m 3 /h<br />

30.1 80-400 m 3 /h<br />

30.2 120-600 m 3 /h<br />

Installation<br />

Installation conditions<br />

The <strong>KPM</strong> can be installed vertically or horizontally (according to the direction of flow indicated in the order). The nominal size of<br />

the product line to be connected must correspond to the nominal size of the <strong>KPM</strong>. The best installation position is between loose<br />

flanges。When installing the device between weld-on flanges, the flange hole pattern has to be turned so that the indicator unit is in a<br />

horizontal position if the pipe arrangement is horizontal. The nominal size of the product line to be connected must correspond to the<br />

nominal size of the <strong>KPM</strong>. Avoid fittings converging on one side directly in front of the device.<br />

The adequate distance to ferromagnetic parts must be observed. During installation, the standard inlet section must be 5 x D<br />

and the standard outlet section 3 x D.<br />

We recommend that the lateral distance between two adjacently mounted devices be 300 mm. The devices can be mounted close<br />

together if vertically offset by one device length. The minimum lateral distance for interfering steel parts should be 200 mm. In case of<br />

doubt, check the interference by moving the device back and forth in the selected distance by about 200 mm and testing whether the<br />

pointer position changes.<br />

Select the mounting location so as to enable a reliable reading of the scale values. Please take note as well of the space<br />

requirement for a possible disassembly of the device.


Installation draft:<br />

Horizontal; from the left to the right Model:<strong>KPM</strong>/L Horizontal; from the right to the left Model:<strong>KPM</strong>/R<br />

Vertical: from the top to the bottom Model:<strong>KPM</strong>/U<br />

Vertical: from the bottom to the top Model :<strong>KPM</strong>/D


Installation size<br />

Sandwich connection<br />

Flange connection<br />

The others same as sandwich


CRK<br />

Chengde Rehe-KROHNE Meters CO., LTD.<br />

Add: Chengde High-Tech Development<br />

Zone Postcode: 067000<br />

Tel: 0314-2120930 2120940 2120875<br />

Fax: 0314-2120920 2120077<br />

E-mail: llh@rehe-krohne.com<br />

Beijing Branch Office<br />

Add: Room 704-707,Fang Heng International Mansion Building B Wang Jing District Beijing<br />

Postcode: 100102<br />

Tel: 010-5875576<br />

Fax: 010-58785476<br />

E-mail: beijing@rehe-krohne.com<br />

Shanghai Office<br />

Add: No.125 Chang Ning Road, Jun Zi Lan Flat 15A, Shanghai<br />

Postcode: 200042<br />

Tel: 021-62408911<br />

Fax: 021-62516350<br />

E-mail: shanghai@rehe-krohne.com<br />

Xinjiang Office<br />

Add: Hongshiyue garden, str. 213 yangtse, Urumqi (wulumiqi)<br />

Tel: 0991-4523018<br />

Fax: 0991-4523018<br />

E-mail: yzh@rehe-krohne.com<br />

Copyright:Chengde Rehe-KROHNE Meters CO.,LTD.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!