10<br />
MAPAL actuating tools<br />
Function principle 3<br />
Coolant pressure<br />
Membrane<br />
Oil<br />
Actuating with coolant pressure<br />
Pressure valve<br />
- Slide actuation is achieved by applying<br />
the existing coolant pressure.<br />
Normally coolant at 50 bar is<br />
required.<br />
- Actuating tools can be <strong>us</strong>ed on<br />
machining centers with the appropriate<br />
level <strong>of</strong> coolant pressure.<br />
Slide<br />
Draw bar<br />
Slide<br />
- Tool feed can be set manually by<br />
means <strong>of</strong> a throttle valve.<br />
- Coolant controlled tools are subject<br />
to very low maintenance as<br />
the coolant pressure is not applied<br />
directly on the moving parts but<br />
via a membrane onto an oil pad<br />
which then lubricates the moving<br />
parts.<br />
- Advantage:<br />
A standard machine can be <strong>us</strong>ed<br />
without special adj<strong>us</strong>tment.