图 例<br />

legend<br />

TV<br />

普 通 二 、 三 插 座<br />

General socket<br />

with 2 and 3 pins(H:0.3m)<br />

电 视 点 接 口<br />

TV node interface(H:1.6m)<br />

数 量 图 例<br />

Quantitylegend<br />

2<br />

10<br />

0<br />

H<br />

D<br />

电 话 插 座<br />

Telephone table<br />

单 孔 网 络 插 座<br />

Single hole<br />

network socket<br />

分 配 电 箱<br />

Panelboard<br />

数 量<br />

Quantity<br />

5<br />

7<br />

0<br />

重 要 提 示 /Important Notes<br />

1.All the installation should be finished by qualified<br />

electrical personnel;<br />

2.All the specifications and models of electrical materials and appliances<br />

should be consistent with the relevant provisions of current national<br />

electrical product stardards;<br />

3.The protection pipes for plastic wires and junction boxes must be flame<br />

retardant andthe appearance should be free of damage and deformation;<br />

4.The appearance of metal wire protection pipes and junction boxes should not<br />

be folded and cracked, with burr-free pipe interior and smooth orifice;<br />

5.Terminal boxes ,junction boxes ,switches and sockets for distribution<br />

system all used in communication systems, should be the same series products.<br />

施 工 要 点 /Key points of <strong>construction</strong><br />

1.When installing the power socket, the left<br />

facing it should be connected to null wire (N),<br />

the right to live wire(L), the middle above to<br />

protective earth wire (PE);<br />

2.The socket panel of power and telephone,etc.<br />

in the same room should be at the same level ,<br />

with a height difference less than 5mm;<br />

3. The bottoms of power socket,TV socket with<br />

eight holes and switch board should<br />

respectively be about 300 mm ,1500 mm - 1700<br />

mm and 1350 mm above the ground .<br />

广 东 欧 珀 移 动 通 讯 有 限 公 司<br />

本 分 - 诚 信 - 创 新 - 团 队<br />

品 质 - 消 费 者 导 向 - 结 果 导 向<br />

D<br />

2500 1000 1000 500<br />

D<br />

D<br />

900 875<br />

Without our company's written<br />

permission,<br />

anycopy of it is forbidden.Never<br />

measure<br />

the drawing in this scale. Always<br />

keeping<br />

in the light of data in the drawing.<br />

Construction company should check the<br />

date in the drawing at building site.<br />

If find<br />

any mistake, please inform the<br />

engineer responsible for the drawing<br />

immediately.<br />

The copyright of the drawing is<br />

reserved<br />

by our company.<br />

插 座 定 位 图<br />

Position drawing of<br />

plug base<br />

项 目 名 称<br />

Item name<br />

1900<br />

<strong>OPPO</strong>- 客 户 服 务 中 心 施 工 图<br />

Construction Drawing of<br />

Customer Service Center<br />

Serial number<br />

编 号<br />

1-140902X-3XH<br />

D<br />

D<br />

日 期<br />

Date<br />

2015.07.09<br />

Company name<br />

910 3075 1230 3075<br />

D D<br />

插 座 定 位 图<br />

1520<br />

公 司 名 称<br />

项 目 负 责 人<br />

Item director<br />

联 系 电 话<br />

Telephone<br />

比 例<br />

Scale<br />

店 形<br />

Shop shape<br />

设 计 师<br />

Designer<br />

联 系 电 话<br />

Telephone<br />

审 核 人<br />

Checker<br />

1:60A4<br />

客 户 服 务 中 心<br />

Customer Service Center<br />

陈 浩<br />

ChenHao<br />

18249504913<br />

注 : 维 修 桌 表 面 为 金 属 结 构 , 务 必 与 地 线 连 接<br />

Note: The metal surface of maintenance table must be connected to protective earth wire (PE).<br />

The 2.0th generation shop design<br />

施 工 监 理 : 区 域 经 理<br />

Construction Supervision: Regional Manager<br />