TFT TRANSMISSIVE <strong>LCD</strong> MODULES<br />

YTS 800SLAA-01-100T<br />

8’’, 800 X 600 DOTS, 1/600 DUTY<br />

TIMING CHARACTERISTICS: HORIZONTAL<br />

PARAMETER SYMBOL MIN. TYP. MAX. UNIT<br />

Horizontal Display Area T HD 800 CLK<br />

CLK Frequency F CLK 40 50 MHz<br />

One Horizontal Line T H 862 1056 1200 CLK<br />

HS Pulse Width T HPW 1 40 CLK<br />

HS Back Porch T HB 46 CLK<br />

HS Front Porch T HFP 16 210 354 CLK<br />

TIMING CHARACTERISTICS: VERTICAL<br />

PARAMETER SYMBOL MIN. TYP. MAX. UNIT<br />

Vertical Display Area T VD 600 th<br />

VS Period Time T V 624 635 700 th<br />

VS Pulse Width T VPW 1 20 th<br />

VS Back Porch T VB 23 th<br />

VS Front Porch T VFP 1 12 77 th<br />

Horizontal Input Timing<br />

Vertical Input Timing<br />

AC CHARACTERISTICS<br />

PARAMETER MIN. TYP. MAX. UNIT<br />

T 1 1 2 ms<br />

T 2 0 60 ms<br />

T 3 200 ms<br />

T 4 200 ms<br />

T 5 1 ms<br />

T 6 1000 ms<br />

Power ON / OFF Sequence<br />

AC CHARACTERISTICS<br />

PARAMETER SYMBOL MIN. TYP. MAX. UNIT<br />

CLKIN Cycle Time T CPH 20 ns<br />

CLKIN Pulse Duty T CWH 40 50 60 %<br />

VSD Setup Time T VST 8 ns<br />

VSD Hold Time T VHD 8 ns<br />

HSD Setup Time T HST 8 ns<br />

HSD Hold Time T HHD 8 ns<br />

Data Setup Time (1) T DSU 8 ns<br />

Data Hold Time (1) T DHD 8 ns<br />

DEN Setup Time T ESU 8 ns<br />

DEN Hold Time T EHD 8 ns<br />

Note (1): D0 [7;0], D1 [7;0], D2 [7;0] to CLKIN.<br />

AC Electrical Characteristics<br />

digital electronic gmbh Tel. +49 (0) 8221/708-0 Fax. +49 (0) 8221/708-80<br />