LÜ-LCD-Dispalys_14
LCD-Displays
LCD-Displays
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TFT TRANSMISSIVE <strong>LCD</strong> MODULES<br />
YTS 800SLAA-01-100T<br />
8’’, 800 X 600 DOTS, 1/600 DUTY<br />
TIMING CHARACTERISTICS: HORIZONTAL<br />
PARAMETER SYMBOL MIN. TYP. MAX. UNIT<br />
Horizontal Display Area T HD 800 CLK<br />
CLK Frequency F CLK 40 50 MHz<br />
One Horizontal Line T H 862 1056 1200 CLK<br />
HS Pulse Width T HPW 1 40 CLK<br />
HS Back Porch T HB 46 CLK<br />
HS Front Porch T HFP 16 210 354 CLK<br />
TIMING CHARACTERISTICS: VERTICAL<br />
PARAMETER SYMBOL MIN. TYP. MAX. UNIT<br />
Vertical Display Area T VD 600 th<br />
VS Period Time T V 624 635 700 th<br />
VS Pulse Width T VPW 1 20 th<br />
VS Back Porch T VB 23 th<br />
VS Front Porch T VFP 1 12 77 th<br />
Horizontal Input Timing<br />
Vertical Input Timing<br />
AC CHARACTERISTICS<br />
PARAMETER MIN. TYP. MAX. UNIT<br />
T 1 1 2 ms<br />
T 2 0 60 ms<br />
T 3 200 ms<br />
T 4 200 ms<br />
T 5 1 ms<br />
T 6 1000 ms<br />
Power ON / OFF Sequence<br />
AC CHARACTERISTICS<br />
PARAMETER SYMBOL MIN. TYP. MAX. UNIT<br />
CLKIN Cycle Time T CPH 20 ns<br />
CLKIN Pulse Duty T CWH 40 50 60 %<br />
VSD Setup Time T VST 8 ns<br />
VSD Hold Time T VHD 8 ns<br />
HSD Setup Time T HST 8 ns<br />
HSD Hold Time T HHD 8 ns<br />
Data Setup Time (1) T DSU 8 ns<br />
Data Hold Time (1) T DHD 8 ns<br />
DEN Setup Time T ESU 8 ns<br />
DEN Hold Time T EHD 8 ns<br />
Note (1): D0 [7;0], D1 [7;0], D2 [7;0] to CLKIN.<br />
AC Electrical Characteristics<br />
digital electronic gmbh Tel. +49 (0) 8221/708-0 Fax. +49 (0) 8221/708-80<br />
All specifications subject to change without notice.<br />
111