Indoor Unit: Outdoor Unit: AER612SH<br />

Insulation of Refrigerant Tubing<br />

IMPORTANT<br />

Indoor unit Outdoor unit<br />

Heat exchanger<br />

Because capillary tubing is used in the outdoor unit, both the<br />

wide and narrow tubes of this <strong>air</strong> <strong>conditioner</strong> become cold. To<br />

prevent heat loss and wet floors due to dripping of<br />

condensation, both tubes must be well insulated with a<br />

proper insulation material. The thickness of the insulation<br />

should be a min. 8 mm.<br />

CAUTION<br />

Wide tube<br />

O.D.<br />

ø12.7 mm<br />

(1/2 ")<br />

Narrow tube<br />

O.D.<br />

ø6.35 mm<br />

(1/4")<br />

Wide tube<br />

<strong>service</strong><br />

valve<br />

Narrow<br />

tube<br />

<strong>service</strong><br />

valve<br />

Muffler<br />

After a tube has been insulated,<br />

never try to bend it into a narrow<br />

curve because it can cause the tube<br />

to break or crack.<br />

14<br />

Accumulator<br />

Strainer<br />

Accumulator<br />

4-way<br />

valve<br />

Capillary<br />

tube<br />

Check<br />

valve<br />

Capillary<br />

Thickness:<br />

Min. 8 mm<br />

Wide tube<br />

Strainer<br />

Compressor<br />

Heat exchanger<br />

Insulation<br />

Cooling cycle<br />

Heating cycle<br />

Narrow tube<br />

Thickness:<br />

Min. 8 mm