38<br />

Single layer<br />

mechnically fixed<br />

Vapour Control Layer<br />

Roll Size: 1.08m x 50m<br />

Apply Micoral NB Heat Activated Self Adhesive VCL bonded to<br />

primed substrate with 75mm side laps <strong>and</strong> 100mm end laps<br />

sealed. The VCL must be dressed at all details to a minimum of<br />

100mm above finished insulation level to allow encapsulation of<br />

insulation.<br />

Insulation<br />

Board Size: 2400mm x 1200mm<br />

Apply Thermazone Foilboard to VCL in half board pattern,<br />

mechanically fixed.<br />

Insulation Boards Laid Half Board Pattern.<br />

<strong>Icopal</strong> <strong>Universal</strong> ®<br />

mechanically fixed<br />

Thermazone Foil<br />

board Insulation<br />

mechanically fixed<br />

Micoral NB Vapour<br />

Control Layer bonded<br />

to primed deck<br />

Metal deck primed<br />

with Xtra-Seal SF<br />

Bitumen Primer