Modular F.R.L. Units<br />

Series <strong>AC</strong>-B<br />

How to Order<br />

Air Combination: Filter Regulator + Lubricator<br />

Series <strong>AC</strong>10A-A<br />

1<br />

L<br />

Symbol<br />

2<br />

<strong>AC</strong>10A-A<br />

<strong>AC</strong>10A M5<br />

q<br />

w<br />

e<br />

A<br />

• Option/Semi-standard: Select one each for a to h.<br />

• Option/Semi-standard symbol: Wh<strong>en</strong> more than one specification is required,<br />

indicate in alphanumeric order.<br />

Example) <strong>AC</strong>10A-M5CG-T-12NR-A<br />

Symbol<br />

Description<br />

q<br />

Option<br />

a<br />

b<br />

Float type auto drain<br />

Pressure gauge<br />

— Without auto drain<br />

C 1)<br />

+<br />

N.C. (Normally closed) Drain port is closed wh<strong>en</strong> pressure is not applied.<br />

— Without pressure gauge<br />

G 2)<br />

+<br />

Round type pressure gauge (without limit indicator)<br />

— Without attachm<strong>en</strong>t<br />

w Attachm<strong>en</strong>t (T-spacer) 3) T Mounting position: AW+T+AL<br />

+<br />

e<br />

Semi-standard<br />

c Set pressure 4) — 0.05 to 0.7 MPa setting<br />

1 0.02 to 0.2 MPa setting<br />

+<br />

d Bowl 5) 2 Metal bowl<br />

— Polycarbonate bowl<br />

e<br />

f<br />

g<br />

h<br />

Lubricator lubricant<br />

exhaust port<br />

Exhaust mechanism<br />

Flow direction<br />

Pressure unit<br />

6 Nylon bowl<br />

+<br />

— Without drain cock<br />

3 Lubricator with drain cock<br />

+<br />

— Relieving type<br />

N<br />

+<br />

Non-relieving type<br />

— Flow direction: Left to right<br />

R<br />

+<br />

Flow direction: Right to left<br />

— Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa<br />

Z Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F<br />

Note 1) Wh<strong>en</strong> pressure is not applied, cond<strong>en</strong>sate which does not start the auto drain mechanism will be left in the bowl.<br />

Releasing the residual cond<strong>en</strong>sate before <strong>en</strong>ding operations for the day is recomm<strong>en</strong>ded.<br />

Note 2) A 1.0 MPa pressure gauge will be fitted. It is not assembled and supplied loose at the time of shipm<strong>en</strong>t.<br />

Note 3) The bracket position varies dep<strong>en</strong>ding on the T-spacer mounting.<br />

Note 4) Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.<br />