Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Modular F.R.L. Units<br />
Series <strong>AC</strong>-B<br />
How to Order<br />
Air Combination: Filter Regulator + Lubricator<br />
Series <strong>AC</strong>10A-A<br />
1<br />
L<br />
Symbol<br />
2<br />
<strong>AC</strong>10A-A<br />
<strong>AC</strong>10A M5<br />
q<br />
w<br />
e<br />
A<br />
• Option/Semi-standard: Select one each for a to h.<br />
• Option/Semi-standard symbol: Wh<strong>en</strong> more than one specification is required,<br />
indicate in alphanumeric order.<br />
Example) <strong>AC</strong>10A-M5CG-T-12NR-A<br />
Symbol<br />
Description<br />
q<br />
Option<br />
a<br />
b<br />
Float type auto drain<br />
Pressure gauge<br />
— Without auto drain<br />
C 1)<br />
+<br />
N.C. (Normally closed) Drain port is closed wh<strong>en</strong> pressure is not applied.<br />
— Without pressure gauge<br />
G 2)<br />
+<br />
Round type pressure gauge (without limit indicator)<br />
— Without attachm<strong>en</strong>t<br />
w Attachm<strong>en</strong>t (T-spacer) 3) T Mounting position: AW+T+AL<br />
+<br />
e<br />
Semi-standard<br />
c Set pressure 4) — 0.05 to 0.7 MPa setting<br />
1 0.02 to 0.2 MPa setting<br />
+<br />
d Bowl 5) 2 Metal bowl<br />
— Polycarbonate bowl<br />
e<br />
f<br />
g<br />
h<br />
Lubricator lubricant<br />
exhaust port<br />
Exhaust mechanism<br />
Flow direction<br />
Pressure unit<br />
6 Nylon bowl<br />
+<br />
— Without drain cock<br />
3 Lubricator with drain cock<br />
+<br />
— Relieving type<br />
N<br />
+<br />
Non-relieving type<br />
— Flow direction: Left to right<br />
R<br />
+<br />
Flow direction: Right to left<br />
— Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa<br />
Z Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F<br />
Note 1) Wh<strong>en</strong> pressure is not applied, cond<strong>en</strong>sate which does not start the auto drain mechanism will be left in the bowl.<br />
Releasing the residual cond<strong>en</strong>sate before <strong>en</strong>ding operations for the day is recomm<strong>en</strong>ded.<br />
Note 2) A 1.0 MPa pressure gauge will be fitted. It is not assembled and supplied loose at the time of shipm<strong>en</strong>t.<br />
Note 3) The bracket position varies dep<strong>en</strong>ding on the T-spacer mounting.<br />
Note 4) Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.<br />
Note 5) Please refer to the g<strong>en</strong>eral catalogue of <strong>AC</strong>-B series on our website http://www.smc.eu for information about Chemical data for chemical resistance of the bowl.<br />
10<br />
For dim<strong>en</strong>sions and other details refer to g<strong>en</strong>eral catalogue series <strong>AC</strong>-B in our website http://www.smc.eu