Accessories for Air Combination<br />

• Options/Attachm<strong>en</strong>ts<br />

Section<br />

Part no.<br />

Model<br />

For <strong>AC</strong>10-A For <strong>AC</strong>20-B For <strong>AC</strong>25-B For <strong>AC</strong>30-B For <strong>AC</strong>40-B For <strong>AC</strong>40-06-B For <strong>AC</strong>50-B For <strong>AC</strong>55-B For <strong>AC</strong>60-B<br />

For <strong>AC</strong>10A-A For <strong>AC</strong>20A-B — For <strong>AC</strong>30A-B For <strong>AC</strong>40A-B For <strong>AC</strong>40A-06-B For <strong>AC</strong>50A-B — For <strong>AC</strong>60A-B<br />

For <strong>AC</strong>10B-A For <strong>AC</strong>20B-B For <strong>AC</strong>25B-B For <strong>AC</strong>30B-B For <strong>AC</strong>40B-B For <strong>AC</strong>40B-06-B For <strong>AC</strong>50B-B For <strong>AC</strong>55B-B For <strong>AC</strong>60B-B<br />

Type<br />

— For <strong>AC</strong>20C-B For <strong>AC</strong>25C-B For <strong>AC</strong>30C-B For <strong>AC</strong>40C-B For <strong>AC</strong>40C-06-B — — —<br />

— For <strong>AC</strong>20D-B — For <strong>AC</strong>30D-B For <strong>AC</strong>40D-B For <strong>AC</strong>40D-06-B — — —<br />

Round Standard G27-10-R1 G36-10-01 G46-10-01<br />

type 0.02 to 0.2 MPa setting G27-10-R1 G36-4-01 G46-4-01<br />

Round type Standard — G36-10-01-L G46-10-01-L<br />

(with colour<br />

zone) 0.02 to 0.2 MPa setting — G36-4-01-L G46-4-01-L<br />

Square Standard — GC3-10AS [GC3P-010AS (Pressure gauge cover only)]<br />

embedded<br />

type 2) 0.02 to 0.2 MPa setting — GC3-4AS [GC3P-010AS (Pressure gauge cover only)]<br />

NPN output/Wiring bottom <strong>en</strong>try<br />

ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] 3)<br />

Digital<br />

NPN output/Wiring top <strong>en</strong>try ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)]<br />

pressure<br />

—<br />

switch<br />

Option<br />

Pressure gauge 1)<br />

Attachm<strong>en</strong>t<br />

PNP output/Wiring bottom <strong>en</strong>try ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] 3)<br />

PNP output/Wiring top <strong>en</strong>try ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] 3)<br />

Float type<br />

N.O. — — AD38-A AD48-A<br />

auto drain 4) N.C. AD17-A AD27-A AD37-A AD47-A<br />

Spacer Y100-A Y200-A Y300-A Y400-A Y500-A Y600-A<br />

Spacer with bracket Y100T-A Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A<br />

Check valve 5) 6) AKM2000-01-A AKM3000-(01)-A AKM4000-(02)-A<br />

—<br />

— — — —<br />

(02)-A<br />

02-A<br />

03-A<br />

Pressure switch 6) — IS10M-20-A IS10M-30-A IS10M-40-A IS10M-50-A IS10M-60-A<br />

Y210-01-A Y310-(01)-A Y410-(02)-A Y510-(02)-A Y610-03-A Y610-(03)-A<br />

T-spacer 5) 6)<br />

Y110-M5-A<br />

(02)-A<br />

02-A<br />

03-A 03-A (04)-A<br />

04-A<br />

02A<br />

Pressure relief<br />

VHS20-01A VHS30-02A<br />

3 port valve 6) —<br />

VHS40-03A VHS40-06A<br />

VHS50-06A — —<br />

02A<br />

03A<br />

10A<br />

04A<br />

Piping adapter 6)<br />

E100-M5-A<br />

Pressure switch with<br />

piping adapter 6) —<br />

Cross spacer 6)<br />

Y14-M5-A<br />

01-A<br />

E200-02-A<br />

03-A<br />

01-A<br />

IS10E-2002-A<br />

03-A<br />

Y24-01-A<br />

02-A<br />

02-A<br />

E300-03-A<br />

04-A<br />

02-A<br />

IS10E-3003-A<br />

04-A<br />

Y34-01-A<br />

02-A<br />

Note 1) in part numbers for a round pressure gauge indicates a pipe thread type.<br />

No indication is necessary for R; however, indicate N for NPT. Please contact<br />

SMC regarding the connection thread NPT and pressure gauge supply for psi<br />

unit specifications.<br />

Note 2) Including one O-ring and 2 mounting screws<br />

Note 3) Lead wire with connector (2 m), adapter, lock pin, O-ring (1 pc.), mounting<br />

screw (2 pcs.) are attached. [ ]: Switch body only.<br />

Regarding how to order the digital pressure switch, please consult with SMC.<br />

02-A<br />

E400-03-A<br />

04-A<br />

06-A<br />

02-A<br />

IS10E-4003-A<br />

04-A<br />

06-A<br />

Y44-02-A<br />

03-A<br />

E500-06-A<br />

E600-06<br />

10<br />

— — — —<br />

Y54-03-A<br />

04-A<br />

— — —<br />

Note 4) Minimum operating pressure: N.O. type–0.1 MPa; N.C. type–0.1 MPa (AD27-A)<br />

and 0.15 MPa (AD37-A/AD47-A). Please consult with SMC separately for psi<br />

and °F unit display specifications.<br />

Note 5) For F.R.L. units, port sizes without ( ) are standard specifications.<br />

Note 6) Separate spacers are required for modular unit.<br />

• Check Valve – Series AKM<br />

A check valve with intermediate air release port can be easily installed to prev<strong>en</strong>t a backflow of<br />

lubricant wh<strong>en</strong> redirecting the air flow and releasing the air on the outlet side of the regulator.<br />

Applicable series:<br />

• Air Filter + Regulator + Lubricator (Series <strong>AC</strong>20 to <strong>AC</strong>40-B)<br />

• Filter Regulator + Lubricator (Series <strong>AC</strong>20A to <strong>AC</strong>40A-B)<br />

Check valve<br />

AKM<br />

w<br />

Pipe thread<br />

type<br />

e By-pass<br />

port size<br />

30 00 01<br />

q<br />

w<br />

e<br />

q<br />

Symbol Description Body size<br />

20 30 40<br />

— Rc<br />

N NPT<br />

F G<br />

+<br />

01 1/8 —<br />

02 1/4<br />

03 3/8 — —<br />

A<br />

Symbol<br />

Specifications<br />

By-pass<br />

Model Effective area [mm 2 ]<br />

Model<br />

Applicable model<br />

port size<br />

AKM2000-A 28<br />

AKM2000-A 1/8, 1/4 <strong>AC</strong>20-B, <strong>AC</strong>20A-B<br />

AKM3000-A 55<br />

<strong>AC</strong>25-B<br />

AKM4000-A 111<br />

AKM3000-A 1/8, 1/4<br />

<strong>AC</strong>30-B, <strong>AC</strong>30A-B<br />

Be sure to use above check valves wh<strong>en</strong><br />

AKM4000-A 1/4, 3/8 <strong>AC</strong>40-B, <strong>AC</strong>40A-B 1) redirecting the air flow on the inlet side of<br />

the lubricator. Threads for IN and OUT<br />

Note 1) Cannot be mounted on the <strong>AC</strong>40-06-B.<br />

ports are not machined.<br />

For dim<strong>en</strong>sions and other details refer to g<strong>en</strong>eral catalogue series <strong>AC</strong>-B in our website http://www.smc.eu<br />

37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!