1.22.1.3 The facility maintains a record of temperature monitoring activities.<br />

Minor Requirements<br />

1.22.2.1 Continuous recording thermometers are placed in all rooms or areas where perishable foods are stored and<br />

handled.<br />

1.22.2.2 Freezers and coolers are provided with vinyl strip doors, self-closing devices, or other methods to maintain<br />

temperatures.<br />

1.23 Cross Contamination Prevention<br />

Incompatible or hazardous materials require separate handling to prevent contamination.<br />

Critical Requirements<br />

1.23.1.1 Incompatible materials (such as raw and cooked products) are stored under conditions that prevent cross<br />

contamination.<br />

1.23.1.2 Measures are taken to prevent cross contamination by hazardous ingredients, such as allergens in storage<br />

areas.<br />

1.23.1.3 Systems are set up to reduce any potential physical, chemical, or microbiological contamination risks.<br />

Ө<br />

1.23.1.8 Protective measures are provided in areas where iced down product is stored over like or dissimilar items in<br />

order to prevent melting ice from contaminating product below.<br />

1.24 Containers and Utensils<br />

If not managed, any food contact containers or utensils have the potential to create food safety hazards.<br />

Ө<br />

Critical Requirements<br />

1.24.1.1 Containers and utensils used to transport, process, hold, or store raw materials, work-in-process, rework, or<br />

fi nished products are constructed, handled, and maintained in a way that prevents contamination.<br />

1.24.1.2 Containers <strong>for</strong> work-in-process or fi nished products are only used <strong>for</strong> their designated purposes.<br />

1.24.1.3 Containers are legibly labeled with contents.<br />

1.26 Finished Product Transportation<br />

Finished product is coded <strong>for</strong> traceability, and shipping requirements are in place to prevent product contamination.<br />

Critical Requirements<br />

1.26.1.1 Legible code marks that are easily seen by consumers are placed on all fi nished products.<br />

1.26.1.2 Code marks satisfy regulatory packaging requirements and lot defi nitions, and are used in the Recall<br />

Program.<br />

1.26.1.3 <strong>Distribution</strong> records identify the initial point of distribution as per regulatory requirements.<br />

1.26.1.4 Finished products are handled and transported in a way that prevents actual or potential contamination.<br />

1.26.1.5 Finished products are loaded or transferred in covered bays or canopies to protect the products from weather<br />

damage.<br />

1.26.1.6 Staging and loading of perishable materials does not pose a food safety risk.<br />

1.26.1.7 Documentation validates that temperature-sensitive products are loaded into pre-cooled vehicles that are<br />

designed to sustain required temperatures during delivery.<br />

1.26.1.8 Temperatures of vehicles are checked and recorded be<strong>for</strong>e loading.<br />

1.26.1.9 The facility en<strong>for</strong>ces transportation breakdown procedures.<br />

1.26.1.10 Prior to loading, all shipping vehicles are inspected <strong>for</strong> cleanliness and structural defects that could<br />

jeopardize the product.<br />

1.26.1.11 Shipping vehicle inspections are documented.<br />

1.26.1.12 Local delivery trucks and route trucks are inspected and cleaned at least weekly to identify potential sources<br />