Rigging<br />

Motorized Pipes: 3 Sets rated at 1000 pounds with control located Stage Right<br />

<strong>Manual</strong> Winch: 1 Set rated at 800 pounds with winch located Stage Left<br />

PLEASE NOTE: Our rigging systems can not be used to carry performers. None of our<br />

rigging equipment is rated to carry people. For shows where performers are to be flown (e.g.<br />

Peter Pan), you must use a recognized company in this field (e.g. “Flying by Foy”, “ZFX!”) to<br />

accomplish the flying effects. THERE ARE NO EXCEPTIONS TO THIS POLICY!<br />

Soft Goods: White Bounce (cyc) 42’ X 26’ Dead Hung at rear of stage<br />

Black Velour Traveller Dead Hung in front of Bounce<br />

Black Velour Traveller Dead Hung at Mid Stage<br />

10 X 8’ X 27’ Black Comm<strong>and</strong>o Cloth Leg (5 sets deployed)<br />

1 X 10’ X 27’ Black Velour Masking Panel<br />

4 X 42’ X 4’ Black Velour Border<br />

1 X 30’ X 20’ Black Sharkstooth Scrim<br />

Burgundy Velour Main Drape (Traveller with valance) Powered draw<br />

operated from Stage Right or control room. <strong>Manual</strong> operation of curtain is<br />

possible from Stage Right.<br />

Power<br />

Lighting: 1 X 100 Amp 3 Ø 5 Wire Disconnect with cable lugs located Stage<br />

Right<br />

Audio: 1 X 60 Amp 3 Ø 5 Wire Disconnect with cable lugs located Stage<br />

Right<br />

Stove Plug: 1 X 50 Amp Stove Plug Connection located in Shipping/Receiving<br />

area (This connection is about 20 feet from the stage. There is a<br />

bulkhead pass-through to allow cable to be run to the stage area.)<br />

PLEASE NOTE: If your production requires tying into disconnects, you will need to arrange a<br />

wiring inspection in advance with the Electrical Safety Authority. Wiring inspections are<br />

m<strong>and</strong>atory for any temporary power tie-in in Ontario.<br />