V. Care and maintenance<br />

Care and maintenance work forms part of the responsibility of the operator. It must be carried out<br />

with care and precision in order to maintain the operational efficiency of the unit.<br />

a) Engine: Maintenance in accordance with the engine<br />

manufacturer’s operating instruction manual<br />

b) High-pressure cleaner<br />

1. Maintenance Schedule:<br />

weekly Oil level: if the oil is milky or if the oil-level has fallen below the “MIN” mark,<br />

change the oil or top it up (see V.2.) as the case may be.<br />

Clean filter of the low-water protection device.<br />

monthly Remove tuyere connection and clean ignition electrodes or adjust<br />

electrode gap.<br />

half-yearly or as<br />

necessary<br />

2. Oil change<br />

– Drain off oil at the drain plug into a collecting tray.<br />

– Fasten drain plug again.<br />

– Fill with oil up to the “MAX” mark.<br />

– Oil type: Hypoid oil SAE 15 W/40. (Order no. 6.288-050, 1 litre)<br />

3. Decarbonising the heating coil<br />

Undo all connections to the boiler cover (cloth seal, spark-plug connector, fuel line, fastening<br />

screws). The boiler is entirely disassembled and the heating coil dismantled. The heating coil can<br />

then be cleaned (e.g. with a second unit).<br />

10<br />

Empty and clean burner fuel tank.<br />

Clean filter before burner fuel pump and fuel nozzle.<br />

Remove sulphur and carbon from heating coil (see V.3.).<br />

Oil change (see V.2.).