Fault Cause Remedy<br />

4. Water jet uneven a)<br />

5. No suction of<br />

cleaning agent<br />

6. Flow protection<br />

does not switch on<br />

– no flame<br />

b)<br />

a)<br />

b)<br />

a)<br />

b)<br />

c)<br />

d)<br />

e)<br />

Nozzle blocked<br />

Safety valve out of adjustment<br />

Cleaning agent filter blocked or<br />

container empty<br />

Cleaning agent hoses, cleaning<br />

agent metering valve leaking or<br />

blocked.<br />

Water supply valve closed<br />

Insufficient water<br />

Strainer in front of flow protection<br />

blocked<br />

Valves in the high-pressure pump<br />

leaking or dirty<br />

Water pressure too low<br />

<strong>HDS</strong> <strong>1000</strong> <strong>DE</strong><br />

Blow nozzle through with<br />

compressed air. If necessary clean<br />

with a pin or similar.<br />

Call in Customer Service<br />

Clean or fill up<br />

Check and clean<br />

Open it<br />

Provide for adequate water supply<br />

Check, dismantle strainer and clean<br />

Check valve plates and seatings,<br />

if necessary replace.<br />

Remedy problem<br />

7. Oil looks milky-white a) Leaking seal Call in Customer Service<br />

13