2<br />

<strong>MTC</strong><br />

60<br />

Insulation class F<br />

Efficiency class<br />

IE2<br />

IE3 available on request<br />

Enclosure class TEFC - Totally Enclosed Fan Cooled<br />

Supply voltage, 60 Hz<br />

(Tolerance ±10%)<br />

3 x 208-230/460 V<br />

As standard all <strong>MTC</strong> motors are supplied with CE<br />

approval.<br />

Shaft seal for <strong>MTC</strong><br />

The operating range of the shaft seal depends on<br />

operating pressure, pump type, type of shaft seal and<br />

liquid temperature.<br />

p<br />

[bar]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Shaft seal Description<br />

AUUV<br />

p<br />

[psi]<br />

400<br />

300<br />

200<br />

100<br />

AUUV<br />

0<br />

0 20 40 60 80 100 120 140 160 180 200 220 T [°F]<br />

-10 0 10 20 30 40 50<br />

O-ring seal with fixed seal<br />

driver, tungsten carbide/<br />

tungsten carbide, FKM<br />

60 70 80 90 100<br />

T [°C]<br />

TM05 4901 2812<br />

Temperature range<br />

[°F (°C)]<br />

+14 °F to +194 °F<br />

(-10 °C to +90 °C)<br />

<strong>MTR</strong>(E), <strong>MTC</strong>, <strong>MTA</strong>