13.12.2012 Views

MTR(E), MTC, MTA - Grundfos

MTR(E), MTC, MTA - Grundfos

MTR(E), MTC, MTA - Grundfos

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MTR</strong>(E), <strong>MTC</strong>, <strong>MTA</strong> 3<br />

<strong>MTA</strong>(H) operating conditions<br />

Temperatures<br />

Permissible liquid temperature [°F (°C)]<br />

Maximum permissible ambient temperature<br />

during operation [°F (°C)]<br />

Permissible ambient temperature<br />

during storage [°F (°C)]<br />

Sound pressure level<br />

Vibration level<br />

Vibration velocity RMS < 0.07 in/s (1.8 mm/s).<br />

Vibration to ISO 10816-1 class IB.<br />

<strong>MTA</strong>(H) motor data<br />

Electrical data<br />

+32 to +140<br />

(0 to +60)<br />

+104<br />

(+40)<br />

-58 to +158<br />

(-50 to +70)<br />

Pump<br />

Motor power<br />

[W]<br />

[dB(A)]<br />

<strong>MTA</strong> 30 100 < 45<br />

<strong>MTA</strong> 60 180 < 45<br />

<strong>MTA</strong> 90 250 < 45<br />

<strong>MTA</strong> 120 400 < 62<br />

<strong>MTA</strong> 200 750 < 62<br />

<strong>MTA</strong> 20H 100 < 45<br />

<strong>MTA</strong> 40H 180 < 45<br />

<strong>MTA</strong> 70H 250 < 45<br />

<strong>MTA</strong> 100H 400 < 62<br />

Power supply<br />

(tolerance ± 10 %)<br />

60 Hz<br />

3 x 200-220 V<br />

3 x 208-230/460 V<br />

Efficiency class <strong>MTA</strong> 200, 750W* IE3<br />

Enclosure class to<br />

IEC 60034-5<br />

IP54<br />

Insulation class F<br />

* Motors smaller than 750W are not covered by the IE standard.<br />

We do not recommend operation via a variable<br />

frequency drive (VFD).<br />

Maximum number of starts<br />

Recommended maximum number of starts per hour<br />

is 250.<br />

85<br />

<strong>MTA</strong>(H)