Ultimate Limit State Design<br />

Concrete Temperature Range: 40 0 C/24 0 C (Maximum long term 24 0 C and Maximum short term 40 0 C).<br />

Concrete Thickness = 1xh min<br />

where h min<br />

as per ETA.<br />

Hole condition: Dry/wet, non-flooded hole.<br />

Drilling method: HAMMER DRILLED HOLES ONLY (Information is not valid for core drilled holes).<br />

Edge Distance: No concrete edge distance effect considered.(i.e. edge distance > maximum (10 X h eff<br />

& 60 X d) in all directions).<br />

Spacing between anchors: The values are for single anchors installed well away from concrete edges and other anchors. No spacing effects considered.<br />

UNCRACKED CONCRETE<br />

Single Anchor Load Capacities (kN) for Threaded Rod (static or quasi-static loads)<br />

Anchor<br />

Size<br />

(mm)<br />

Hole<br />

Size<br />

(mm)<br />

8 10<br />

10 12<br />

12 14<br />

16 18<br />

20 24<br />

24 28<br />

30 35<br />

Depth<br />

h eff<br />

(mm)<br />

Concrete<br />

Thickness<br />

(mm)<br />

Class 5.8 Threaded Rod Class 8.8 Threaded Rod A4-50 Stainless Steel<br />

Tension Load (Concrete) Shear<br />

Load<br />

(Steel)<br />

Tension Load (Concrete) Shear<br />

Load<br />

(Steel)<br />

Tension Load (Concrete) Shear<br />

Load<br />

(Steel)<br />

20MPa 32MPa 40MPa 50MPa 20MPa 32MPa 40MPa 50MPa 20MPa 32MPa 40MPa 50MPa<br />

60 100 11.1 11.6 11.9 12.2<br />

11.1 11.6 11.9 12.2<br />

80 110<br />

7.3 14.7 15.5 15.9 16.2<br />

12.2<br />

100 130 18.4 19.3 19.5<br />

60 100 13.0 14.3 14.7 15.0<br />

13.0 14.3 14.7 15.0<br />

90 120<br />

11.6 20.4 21.4 22.1 22.5<br />

19.3<br />

130 160 29.5 30.9<br />

70 100 16.4 20.0 20.6 21.0<br />

16.4 20.0 20.6 21.0<br />

110 140<br />

16.9 29.9 31.4 32.3 32.9<br />

28.1<br />

155 185 42.2 44.2 45.0<br />

80 116 20.1 25.4 28.4 31.1<br />

125 161 39.2 47.6 49.0 49.9 31.3 39.2 47.6 49.0 49.9<br />

215 251 52.2 78.1 81.8 83.6<br />

90 138 24.0 30.3 33.9 37.1<br />

170 218 62.2 78.7 81.6 62.2 78.7 83.3 84.9<br />

49.0<br />

210 258<br />

85.4 99.9 102.9 104.8<br />

81.6<br />

270 318 122.5 128.4 130.6<br />

11.7 6.4 3.8<br />

18.6 10.2 6.1<br />

27.0 14.8 8.9<br />

20.1 25.4 28.4 31.1 C-Pryout 20.1 25.4 27.4<br />

50.1 27.4<br />

24.0 30.3 33.9 37.1 C-Pryout 24.0 30.3 33.9 37.1<br />

78.3 42.8<br />

100 156 28.1 35.5 39.7 43.5 C-Pryout 28.1 35.5 39.7 43.5 C-Pryout 28.1 35.5 39.7 43.5<br />

210 266 85.4 108.0 114.0 116.1<br />

85.4 108.0 114.0 116.1<br />

250 306 110.9 117.5 70.5 110.9 131.7 135.7 138.2<br />

350 406 117.5 175.9 184.4 188.0<br />

112.8 61.7<br />

120 190 36.9 46.6 52.2 57.1 C-Pryout 36.9 46.6 52.2 57.1 C-Pryout 36.9 46.6 52.2 57.1<br />

270 340 124.5 140.7 145.0 147.7<br />

124.5 140.7 145.0 147.7<br />

300 370 145.8 156.4 161.2 164.1 145.8 156.4 161.2 164.1<br />

112.1<br />

350 420 174.1 182.5 186.9 174.1 182.5 188.0 191.5<br />

550 620 186.9 273.6 286.7 295.5 299.0<br />

179.4 98.1<br />

16.5<br />

25.7<br />

37.0<br />

58.9<br />

Capacity is limited by steel strength. C-Pryout: Capacity is limited by the shear concrete pry-out<br />